Quick facts
| Availability | Confirmed on request |
| Category | Purge and Pressurization System (Type X) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can EPV-6000-** be shipped?
EPV-6000-** is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up EPV-6000-** in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for EPV-6000-** and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for EPV-6000-**, subject to availability and destination.
6000 Series Vent. EPV-6000 Vent. Series: 6000 Series. System: Type X Purge ; Ex pxb Purge. Number of volume exchanges: 4 to 19. Hazardous environment: gas, dust, gas and dust. Connection: . PowerIntrinsically Safe back to 6000 control unitSignalBUS back to 6000 control unitConnectionM12 connector, 4-pin: . Power: Intrinsically Safe back to 6000 control unit. Signal: BUS back to 6000 control unit. Connection: M12 connector, 4-pin. LED indication: power: green vent number: yellow, on for second vent. Protective gas supply: instrument grade air or inert gas. Safe pressure: Gas: 0.25" wc (6.4 mm wc) (0.625 mbar) (62 Pa) Dust: 0.65" wc (16.5 mm wc) (1.6 mbar) (162 Pa) Gas and Dust: 0.65" wc (16.5 mm wc) (1.6 mbar) ( 162 Pa). Enclosure pressure: 25 mbar (0 ... 9.9 in. w.c.). Max. enclosure pressure: 62 mbar (25 in. w.c.). Purge flow rate: Maximum flow rate measurement for enclosure size (enclosure volume:flow rate):< 20 ft3 (0.57 m3): 5, 12 SCFM (141, 340 l/min), or dynamic20 ... 30 ft3 (0.57 ... 0.85 m3): 5, 12, 20 SCFM (141, 340, 565 l/min), or dynamic> 30 ft3 (0.85 m3): 5, 12, 20, 30 SCFM (141, 340, 565, 850 l/min), or dynamic. Purge flow and enclosure pressure rate: With EPV-6000-xx-01, EPV-6000-xx-02141 l/min @ 3.7 mbar, (5 scfm @ 1.5 in w.c.)340 l/min @ 5.0 mbar, (12 scfm @ 2.0 in. w.c.)565 l/min @ 6.7 mbar, (20 scfm @ 2.7 in. w.c.)850 l/min @ 10.2 mbar, (30 scfm @ 4.1 in. w.c.) With EPV-6000-xx-03, EPV-6000-xx-04141 l/min @ 5.2 mbar, (5 scfm @ 2.1 in. w.c.)340 l/min @ 6.5 mbar, (12 scfm @ 2.6 in. w.c.)565 l/min @ 10.2 mbar, (20 scfm @ 4.1 in. w.c.)850 l/min @ 13.2 mbar, (30 scfm @ 5.3 in. w.c.) With EPV-6000-xx-05, 06141 l/min @ 4.1 mbar, (5 scfm @ 1.64 in. w.c.)340 l/min @ 5.5 mbar, (12 scfm @ 2.20 in. w.c.)565 l/min @ 14.9 mbar, (20 scfm @ 6.00 in. w.c.). Flow rate for leakage compensation: Depends on enclosure seal.EPV-6000-xx-01, EPV-6000-xx-0210.0 l/min (0.35 scfm) @ 0.63 mbar (0.25 in. w.c.)28.0 l/min (1.0 scfm) @ 1.9 mbar (0.75 in. w.c.) EPV-6000-xx-03, EPV-6000-xx-046.2 l/min (0.22 scfm) @ 0.63 mbar (0.25 in. w.c.)16.4 l/min (0.58 scfm) @ 1.9 mbar (0.75 in. w.c.)EPV-6000-xx-05, EPV-6000-xx-06Less than 1 l/min (0.035 scfm) @ 0.63 mbar (0.25 in. w.c.)Less than 1 l/min (0.035 scfm) @1.9 mbar (0.75 in. w.c.). Breaking pressure: EPV-6000-xx-01, EPV-6000-xx-02: 2.0 mbar (0.8 in. w.c.) EPV-6000-xx-03, EPV-6000-xx-04: 3.2 ... 3.5 mbar (1.3 ... 1.4 in. w.c.) EPV-6000-xx-05, EPV-6000-xx-06: 3.5 ... 3.8 mbar (1.4 ... 1.5 in. w.c.). Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013EN 61000-6-2:2005: . Directive 2014/30/EU: EN 61326-1:2013EN 61000-6-2:2005. RoHS: . Directive 2011/65/EU (RoHS)EN IEC 63000:2018: . Directive 2011/65/EU (RoHS): EN IEC 63000:2018. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -30 ... 80 °C (-22 ... 176 °F). Relative humidity: 5 ... 95 %, noncondensing. Vibration resistance: 5 ... 100 Hz , 1 g, 12 m/s2, all axes. Impact resistance: 30 g, 11 ms, all axes. Material: EPV-6000-AA-.... Cap: marine grade 5052 anodized aluminum, marine grade 6061T6 anodized aluminum EPV-6000-SS-.... Cap: 316L (UNS S31603) stainless steel; Body: marine grade 6061T6 anodized aluminum. Spark arrestor304 (UNS S30400) stainless steel: . Spark arrestor: 304 (UNS S30400) stainless steel. Installation: - any orientation to enclosure- not gravity dependent- internal and external mounting possible. Mass: approx. 1.4 kg (3.1 lb). Dimensions: 127.5 x 146 x 82.5 mm (5.05 x 5.75 x 3.25 inch). Height146 mmWidth127.5 mmDepth82.5 mm: . Height: 146 mm. Width: 127.5 mm. Depth: 82.5 mm. Mounting: 1 1/2" NPT knockout (50.8 mm (2") hole) with sealed nut. EU-type examination certificate: DEMKO 15 ATEX 1622X. MarkingII 2 G Ex ib [pxb Gb] IIC T4 GbII 2 D Ex ib [pxb Db] IIIC T135 °C Db-20 °C ≤ Ta ≤ 60 °C: . Marking: II 2 G Ex ib [pxb Gb] IIC T4 GbII 2 D Ex ib [pxb Db] IIIC T135 °C Db-20 °C ≤ Ta ≤ 60 °C. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-11:2012. UL approval: cULusClass I, Division 1, Groups A, B, C, DIP66/Type 4XClass I, Zone 1, Groups IIC, T4Class II, Division 1, Groups E, F, GClass II, Zone 21, Group IIIC T135 °C-20 °C ≤ TA ≤ 60 °CEx i intrinsically safe. IECEx approval: Ex ib [pxb Gb] IIC T4 GbEx ib [pxb Db] IIIC T135 °C Db-20 °C ≤ Ta ≤ 60 °CIECEx UL 15.0147X. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Series | 6000 Series |
| System | Type X Purge ; Ex pxb Purge |
| Number of volume exchanges | 4 to 19 |
| Hazardous environment | gas, dust, gas and dust |
Electrical specifications
| Connection | |
| PowerIntrinsically Safe back to 6000 control unitSignalBUS back to 6000 control unitConnectionM12 connector, 4-pin | Power |
| Power | Intrinsically Safe back to 6000 control unit |
| Signal | BUS back to 6000 control unit |
| Connection | M12 connector, 4-pin |
Indicators/settings
| LED indication | power: green vent number: yellow, on for second vent |
Pneumatic parameters
| Protective gas supply | instrument grade air or inert gas |
| Safe pressure | Gas: 0.25" wc (6.4 mm wc) (0.625 mbar) (62 Pa) Dust: 0.65" wc (16.5 mm wc) (1.6 mbar) (162 Pa) Gas and Dust: 0.65" wc (16.5 mm wc) (1.6 mbar) ( 162 Pa) |
| Enclosure pressure | 25 mbar (0 ... 9.9 in. w.c.) |
| Max. enclosure pressure | 62 mbar (25 in. w.c.) |
| Purge flow rate | Maximum flow rate measurement for enclosure size (enclosure volume:flow rate):< 20 ft3 (0.57 m3): 5, 12 SCFM (141, 340 l/min), or dynamic20 ... 30 ft3 (0.57 ... 0.85 m3): 5, 12, 20 SCFM (141, 340, 565 l/min), or dynamic> 30 ft3 (0.85 m3): 5, 12, 20, 30 SCFM (141, 340, 565, 850 l/min), or dynamic |
| Purge flow and enclosure pressure rate | With EPV-6000-xx-01, EPV-6000-xx-02141 l/min @ 3.7 mbar, (5 scfm @ 1.5 in w.c.)340 l/min @ 5.0 mbar, (12 scfm @ 2.0 in. w.c.)565 l/min @ 6.7 mbar, (20 scfm @ 2.7 in. w.c.)850 l/min @ 10.2 mbar, (30 scfm @ 4.1 in. w.c.) With EPV-6000-xx-03, EPV-6000-xx-04141 l/min @ 5.2 mbar, (5 scfm @ 2.1 in. w.c.)340 l/min @ 6.5 mbar, (12 scfm @ 2.6 in. w.c.)565 l/min @ 10.2 mbar, (20 scfm @ 4.1 in. w.c.)850 l/min @ 13.2 mbar, (30 scfm @ 5.3 in. w.c.) With EPV-6000-xx-05, 06141 l/min @ 4.1 mbar, (5 scfm @ 1.64 in. w.c.)340 l/min @ 5.5 mbar, (12 scfm @ 2.20 in. w.c.)565 l/min @ 14.9 mbar, (20 scfm @ 6.00 in. w.c.) |
| Flow rate for leakage compensation | Depends on enclosure seal.EPV-6000-xx-01, EPV-6000-xx-0210.0 l/min (0.35 scfm) @ 0.63 mbar (0.25 in. w.c.)28.0 l/min (1.0 scfm) @ 1.9 mbar (0.75 in. w.c.) EPV-6000-xx-03, EPV-6000-xx-046.2 l/min (0.22 scfm) @ 0.63 mbar (0.25 in. w.c.)16.4 l/min (0.58 scfm) @ 1.9 mbar (0.75 in. w.c.)EPV-6000-xx-05, EPV-6000-xx-06Less than 1 l/min (0.035 scfm) @ 0.63 mbar (0.25 in. w.c.)Less than 1 l/min (0.035 scfm) @1.9 mbar (0.75 in. w.c.) |
| Breaking pressure | EPV-6000-xx-01, EPV-6000-xx-02: 2.0 mbar (0.8 in. w.c.) EPV-6000-xx-03, EPV-6000-xx-04: 3.2 ... 3.5 mbar (1.3 ... 1.4 in. w.c.) EPV-6000-xx-05, EPV-6000-xx-06: 3.5 ... 3.8 mbar (1.4 ... 1.5 in. w.c.) |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013EN 61000-6-2:2005 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013EN 61000-6-2:2005 |
| RoHS | |
| Directive 2011/65/EU (RoHS)EN IEC 63000:2018 | Directive 2011/65/EU (RoHS) |
| Directive 2011/65/EU (RoHS) | EN IEC 63000:2018 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -30 ... 80 °C (-22 ... 176 °F) |
| Relative humidity | 5 ... 95 %, noncondensing |
| Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes |
| Impact resistance | 30 g, 11 ms, all axes |
Mechanical specifications
| Material | EPV-6000-AA-.... Cap: marine grade 5052 anodized aluminum, marine grade 6061T6 anodized aluminum EPV-6000-SS-.... Cap: 316L (UNS S31603) stainless steel; Body: marine grade 6061T6 anodized aluminum |
| Spark arrestor304 (UNS S30400) stainless steel | Spark arrestor |
| Spark arrestor | 304 (UNS S30400) stainless steel |
| Installation | - any orientation to enclosure- not gravity dependent- internal and external mounting possible |
| Mass | approx. 1.4 kg (3.1 lb) |
| Dimensions | 127.5 x 146 x 82.5 mm (5.05 x 5.75 x 3.25 inch) |
| Height146 mmWidth127.5 mmDepth82.5 mm | Height |
| Height | 146 mm |
| Width | 127.5 mm |
| Depth | 82.5 mm |
| Mounting | 1 1/2" NPT knockout (50.8 mm (2") hole) with sealed nut |
Data for application in connection with hazardous areas
| EU-type examination certificate | DEMKO 15 ATEX 1622X |
| MarkingII 2 G Ex ib [pxb Gb] IIC T4 GbII 2 D Ex ib [pxb Db] IIIC T135 °C Db-20 °C ≤ Ta ≤ 60 °C | Marking |
| Marking | II 2 G Ex ib [pxb Gb] IIC T4 GbII 2 D Ex ib [pxb Db] IIIC T135 °C Db-20 °C ≤ Ta ≤ 60 °C |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-11:2012 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-11:2012 |
International approvals
| UL approval | cULusClass I, Division 1, Groups A, B, C, DIP66/Type 4XClass I, Zone 1, Groups IIC, T4Class II, Division 1, Groups E, F, GClass II, Zone 21, Group IIIC T135 °C-20 °C ≤ TA ≤ 60 °CEx i intrinsically safe |
| IECEx approval | Ex ib [pxb Gb] IIC T4 GbEx ib [pxb Db] IIIC T135 °C Db-20 °C ≤ Ta ≤ 60 °CIECEx UL 15.0147X |
General information