Pepperl Fuchs VBG-ENX-K30-DMD-S16-EV
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Ethernet Devices |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VBG-ENX-K30-DMD-S16-EV be shipped?
VBG-ENX-K30-DMD-S16-EV is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBG-ENX-K30-DMD-S16-EV in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBG-ENX-K30-DMD-S16-EV and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBG-ENX-K30-DMD-S16-EV, subject to availability and destination.
AS-Interface Gateway/Safety Monitor. EtherNet/IP und Modbus TCP gateway with integrated safety monitor, double master for 2 AS-Interface networks, power supply input with data decoupling. AS-Interface specification: V3.0. PLC-Functionality: activateable. Duplicate address detection: from AS-Interface slaves. Earth fault detection: integrated. EMC monitoring: integrated. Diagnostics function: Extended function via display. Data decoupling: integrated. Switch-on delay: < 10 s. Response delay: < 40 ms. UL File Number: E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source. Safety Integrity Level (SIL): SIL 3. Performance level (PL): PL e. MTTFd: 200 a. B10d: 2 E+7. Display: Illuminated graphical LC display for addressing and error messages. LED ETHERNET: ethernet active; LED green. LED AS-i ACTIVE: AS-Interface operation normal; LED green. LED CONFIG ERR: configuration error; LED red. LED PRG ENABLE: autom. programming; LED green. LED POWER: voltage ON; LED green. LED PRJ MODE: projecting mode active; LED yellow. LED U AS-i: AS-Interface voltage; LED green. LED AUX: ext. auxiliary voltage UAUX ; LED green. LED EDM/Start: External device monitoring circuit inputs closed, 4x yellow LEDs. LED output circuit: Output circuit closed; 4 x green LEDs. Button: 4. Switch SET: Selection and setting of a slave address. OK button: Mode selection traditional-graphical/confirmation. Button MODE: Mode selection PRJ-operation/save configuration/cursor. ESC button: Mode selection traditional-graphical/cancel. Insulation voltage: ≥ 500 V. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface; Output K3 and K4 24 V DC. Rated operating current: ≤ 300 mA from AS-Interface. Power supply: max. 4 A per AS-Interface circuit. Interface type: 2 x RJ-45. Protocol: EtherNet/IP + MODBUS TCP/IP acc. to IEEE 802.3 supports device level ring protocol DLR. Transfer rate: 10 MBit/s / 100 MBit/s , Automatic baud rate detection. Interface type: Ethernet: RJ-45 Diagnostic Interface. Transfer rate: 10 MBit/s. Interface type: Chip card slot. Number/Type: 4 EDM/Start inputs:EDM: Inputs for the external device monitoring circuitsStart: start inputs:Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs). Safety output: Output circuits 1 and 2: 2 potential-free contacts,max. contact load:3 ADC-13 at 30 VDC,3 AAC-15 at 30 VACOutput circuits 3 and 4: 2 PNP transistor outputsmax. contact load:0.5 ADC-13 at 30 VDC. Ethernet: RJ-45. AS-Interface: spring terminals, removable. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007. Machinery Directive: . Directive 2006/42/ECEN 61508-1:2010 EN/ISO 13849-1:2008 EN 62061:2005: . Directive 2006/42/EC: EN 61508-1:2010 EN/ISO 13849-1:2008 EN 62061:2005. Electromagnetic compatibility: EN 61000-6-2:2005, EN 61000-6-4:2007. Degree of protection: EN 60529:2000. AS-Interface: EN 62026-2:2013. Shock resistance: EN 61131-2:2004. Standards: EN 61000-6-2:2005, EN 61000-6-4:2007 EN 61326-3-1:2008 IEC 61508:2010 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e). UL approval: An isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device.. Ambient temperature: 0 ... 55 °C (32 ... 131 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Degree of protection: IP20. Material: . HousingStainless steel: . Housing: Stainless steel. Mass: 800 g. Dimensions: . Height120 mmWidth110 mmLength89 mm: . Height: 120 mm. Width: 110 mm. Length: 89 mm. Construction type: Low profile housing , Stainless steel
Specifications
General specifications
| AS-Interface specification | V3.0 |
| PLC-Functionality | activateable |
| Duplicate address detection | from AS-Interface slaves |
| Earth fault detection | integrated EFD |
| EMC monitoring | integrated |
| Diagnostics function | Extended function via display |
| Data decoupling | integrated |
| Switch-on delay | < 10 s |
| Response delay | < 40 ms |
| UL File Number | E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| Performance level (PL) | PL e |
| MTTFd | 200 a |
| B10d | 2 E+7 |
Indicators/operating means
| Display | Illuminated graphical LC display for addressing and error messages |
| LED ETHERNET | ethernet active; LED green |
| LED AS-i ACTIVE | AS-Interface operation normal; LED green |
| LED CONFIG ERR | configuration error; LED red |
| LED PRG ENABLE | autom. programming; LED green |
| LED POWER | voltage ON; LED green |
| LED PRJ MODE | projecting mode active; LED yellow |
| LED U AS-i | AS-Interface voltage; LED green |
| LED AUX | ext. auxiliary voltage UAUX ; LED green |
| LED EDM/Start | External device monitoring circuit inputs closed, 4x yellow LEDs |
| LED output circuit | Output circuit closed; 4 x green LEDs |
| Button | 4 |
| Switch SET | Selection and setting of a slave address |
| OK button | Mode selection traditional-graphical/confirmation |
| Button MODE | Mode selection PRJ-operation/save configuration/cursor |
| ESC button | Mode selection traditional-graphical/cancel |
Electrical specifications
| Insulation voltage | ≥ 500 V Ui |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface; Output K3 and K4 24 V DC Ue |
| Rated operating current | ≤ 300 mA from AS-Interface Ie |
| Power supply | max. 4 A per AS-Interface circuit |
Interface 1
| Interface type | 2 x RJ-45 |
| Protocol | EtherNet/IP + MODBUS TCP/IP acc. to IEEE 802.3 supports device level ring protocol DLR |
| Transfer rate | 10 MBit/s / 100 MBit/s , Automatic baud rate detection |
Interface 2
| Interface type | Ethernet: RJ-45 Diagnostic Interface |
| Transfer rate | 10 MBit/s |
Interface 3
| Interface type | Chip card slot |
Input
| Number/Type | 4 EDM/Start inputs:EDM: Inputs for the external device monitoring circuitsStart: start inputs:Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs) |
Output
| Safety output | Output circuits 1 and 2: 2 potential-free contacts,max. contact load:3 ADC-13 at 30 VDC,3 AAC-15 at 30 VACOutput circuits 3 and 4: 2 PNP transistor outputsmax. contact load:0.5 ADC-13 at 30 VDC |
Connection
| Ethernet | RJ-45 |
| AS-Interface | spring terminals, removable |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 |
| Machinery Directive | |
| Directive 2006/42/ECEN 61508-1:2010 EN/ISO 13849-1:2008 EN 62061:2005 | Directive 2006/42/EC |
| Directive 2006/42/EC | EN 61508-1:2010 EN/ISO 13849-1:2008 EN 62061:2005 |
Standard conformity
| Electromagnetic compatibility | EN 61000-6-2:2005, EN 61000-6-4:2007 |
| Degree of protection | EN 60529:2000 |
| AS-Interface | EN 62026-2:2013 |
| Shock resistance | EN 61131-2:2004 |
| Standards | EN 61000-6-2:2005, EN 61000-6-4:2007 EN 61326-3-1:2008 IEC 61508:2010 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e) |
Approvals and certificates
| UL approval | An isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. |
Ambient conditions
| Ambient temperature | 0 ... 55 °C (32 ... 131 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Material | |
| HousingStainless steel | Housing |
| Housing | Stainless steel |
| Mass | 800 g |
| Dimensions | |
| Height120 mmWidth110 mmLength89 mm | Height |
| Height | 120 mm |
| Width | 110 mm |
| Length | 89 mm |
| Construction type | Low profile housing , Stainless steel |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs VBA-LT2-G1
Available on requestPepperl Fuchs VBA-LT2-G1-2YE
Available on requestPepperl Fuchs VBG-CCL-K20-D-BV
Available on requestPepperl Fuchs VBG-DN-K20-D
Available on requestPepperl Fuchs VBG-EP1-KE5-D
Available on requestPepperl Fuchs VBG-MOD-K20-D
Available on requestPepperl Fuchs VBG-PB-K20-D-EV1
Available on requestPepperl Fuchs VBG-PB-K20-D-EV24