Pepperl Fuchs VAA-2E2A-G12-SAJ/EA2L
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Safety at Work |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VAA-2E2A-G12-SAJ/EA2L be shipped?
VAA-2E2A-G12-SAJ/EA2L is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VAA-2E2A-G12-SAJ/EA2L in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VAA-2E2A-G12-SAJ/EA2L and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VAA-2E2A-G12-SAJ/EA2L, subject to availability and destination.
AS-Interface safety module. G12 safety module, 2 safety inputs and 2 standard electronic outputs. Node type: Safety node. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.1. Profile: S-7.B. IO code7ID codeBID1 codeFID2 code0: . IO code: 7. ID code: B. ID1 code: F. ID2 code: 0. UL File Number: E223772. Safety Integrity Level (SIL): SIL 3. Performance level (PL): PL e. Category: Cat. 4. MTTFd: no significant contribution to MTTFd of the overall system. PFHd: no significant contribution to PFH of the overall system. PFD: no significant contribution to PFD of the overall system. LED FAULT: error display; LED redred: communication error or address is 0red flashing: Output supply overload. LED PWR: AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0. LED AUX: ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage. LED IN: switching state (input); 2 LED yellow. LED OUT: Switching status (output); 2 yellow/red LEDs Yellow: output activeRed: output overload. Auxiliary voltage (output): 24 V DC ± 15 % PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 50 mA. Protection class: III. Surge protection: UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral. Rated insulation voltage: 40 V. Pulse withstand voltage: 0.5 kV. Number/Type: 2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1 Cable length must not exceed 300 m per input.. Supply: from AS-Interface. Voltage: 20 ... 30 V DC pulsed. Current loading capacity: input current limited ≤ 15 mA,overload and short-circuit resistant. Number/Type: 2 conventional electronic outputs, PNP. Supply: from external auxiliary voltage UAUX. Voltage: ≥ (UAUX - 0.5 V). Current: 1.5 A per output , short-circuit protected. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013+A1:2019 IEC 60947-5-3:1999: . Directive 2014/30/EU: EN 62026-2:2013+A1:2019 IEC 60947-5-3:1999. Machinery Directive: . Directive 2006/42/ECEN ISO 13849-1:2008 + AC:2009 EN ISO 13849-2:2012 EN 62061:2005: . Directive 2006/42/EC: EN ISO 13849-1:2008 + AC:2009 EN ISO 13849-2:2012 EN 62061:2005. Insulation coordination: EN 60947-1:2007. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Electrical safety: IEC 60947-1, NFPA 79, IEC 60204-1:2007. Emitted interference: EN 61000-6-4:2007/A1:2011. AS-Interface: EN 62026-2:2013+A1:2019. Noise immunity: IEC 62026-2:2008 EN 62061:2005 EN 61000-6-2:2005. Functional safety: ISO 13849-1 (up to category 4/PL e), IEC 61508/IEC 62061 (up to SIL3). Standards: NFPA 79:2007 ER 1. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Shock and impact resistance: 30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks. Vibration resistance: 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles. Pollution degree: 3. Degree of protection: IP67. Connection: Cable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector. Material: . HousingPBT: . Housing: PBT. Mass: 200 g. Tightening torque, cable gland: 0.4 Nm. Dimensions: . Height35 mmWidth57.4 mmLength118 mm: . Height: 35 mm. Width: 57.4 mm. Length: 118 mm. Mounting: Mounting plate
Specifications
General specifications
| Node type | Safety node |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V2.1 |
| Profile | S-7.B |
| IO code7ID codeBID1 codeFID2 code0 | IO code |
| IO code | 7 |
| ID code | B |
| ID1 code | F |
| ID2 code | 0 |
| UL File Number | E223772 |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| Performance level (PL) | PL e |
| Category | Cat. 4 |
| MTTFd | no significant contribution to MTTFd of the overall system |
| PFHd | no significant contribution to PFH of the overall system |
| PFD | no significant contribution to PFD of the overall system |
Indicators/operating means
| LED FAULT | error display; LED redred: communication error or address is 0red flashing: Output supply overload |
| LED PWR | AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage |
| LED IN | switching state (input); 2 LED yellow |
| LED OUT | Switching status (output); 2 yellow/red LEDs Yellow: output activeRed: output overload |
Electrical specifications
| Auxiliary voltage (output) | 24 V DC ± 15 % PELV UAUX |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 50 mA Ie |
| Protection class | III |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral |
| Rated insulation voltage | 40 V |
| Pulse withstand voltage | 0.5 kV |
Input
| Number/Type | 2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1 Cable length must not exceed 300 m per input. |
| Supply | from AS-Interface |
| Voltage | 20 ... 30 V DC pulsed |
| Current loading capacity | input current limited ≤ 15 mA,overload and short-circuit resistant |
Output
| Number/Type | 2 conventional electronic outputs, PNP |
| Supply | from external auxiliary voltage UAUX |
| Voltage | ≥ (UAUX - 0.5 V) |
| Current | 1.5 A per output , short-circuit protected |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013+A1:2019 IEC 60947-5-3:1999 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013+A1:2019 IEC 60947-5-3:1999 |
| Machinery Directive | |
| Directive 2006/42/ECEN ISO 13849-1:2008 + AC:2009 EN ISO 13849-2:2012 EN 62061:2005 | Directive 2006/42/EC |
| Directive 2006/42/EC | EN ISO 13849-1:2008 + AC:2009 EN ISO 13849-2:2012 EN 62061:2005 |
Standard conformity
| Insulation coordination | EN 60947-1:2007 |
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Electrical safety | IEC 60947-1, NFPA 79, IEC 60204-1:2007 |
| Emitted interference | EN 61000-6-4:2007/A1:2011 |
| AS-Interface | EN 62026-2:2013+A1:2019 |
| Noise immunity | IEC 62026-2:2008 EN 62061:2005 EN 61000-6-2:2005 |
| Functional safety | ISO 13849-1 (up to category 4/PL e), IEC 61508/IEC 62061 (up to SIL3) |
| Standards | NFPA 79:2007 ER 1 |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks |
| Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
| Pollution degree | 3 |
Mechanical specifications
| Degree of protection | IP67 |
| Connection | Cable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector |
| Material | |
| HousingPBT | Housing |
| Housing | PBT |
| Mass | 200 g |
| Tightening torque, cable gland | 0.4 Nm |
| Dimensions | |
| Height35 mmWidth57.4 mmLength118 mm | Height |
| Height | 35 mm |
| Width | 57.4 mm |
| Length | 118 mm |
| Mounting | Mounting plate |