Available on request

Pepperl Fuchs VAA-2E1A-G10-SAJ/EA2J-2X1M

MPN: VAA-2E1A-G10-SAJ/EA2J-2X1M · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategorySafety at Work
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can VAA-2E1A-G10-SAJ/EA2J-2X1M be shipped?

VAA-2E1A-G10-SAJ/EA2J-2X1M is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up VAA-2E1A-G10-SAJ/EA2J-2X1M in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for VAA-2E1A-G10-SAJ/EA2J-2X1M and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VAA-2E1A-G10-SAJ/EA2J-2X1M, subject to availability and destination.

AS-Interface safety module. G10 safety module, 2 safety-related inputs and 1 standard electronic output. Node type: Safety-Slave. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.1. UL File Number: E223772 "For use in NFPA 79 Applications only". LED FLT: error display; LED redred: communication error or address is 0. LED AS-i: AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0. LED IN: switching state (input); 2 LED yellow. LED OUT: Switching state (output); LED yellow. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface (PELV). Rated operating current: ≤ 90 mA. Protection class: III. Surge protection: overvoltage category III. Rated insulation voltage: 32 V. Pulse withstand voltage: 0.8 kV. Number/Type: 2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1. Supply: from AS-Interface. Voltage: 20 ... 30 V DC pulsed. Current: input current limited ≤ 15 mA,short-circuit protected. Number/Type: 1 conventional electronic output, PNP. Supply: from AS-Interface. Voltage: (UASI - 7.0 V) ≤ UOUT ≤ UASI. Current: 50 mA , short-circuit/overload protected. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007. Machinery Directive: . Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015: . Directive 2006/42/EC: EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Electrical safety: IEC 61140:2009. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: IEC 62026-2:2013 EN 62061:2005 EN 61000-6-2:2005. Functional safety: EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015. Profile: S-7.B. IO code: 7. ID code: B. ID1 code: F. ID2 code: 0. Data bits (function via AS-Interface): InputOutput. D0 dyn. safety code 1 OUT 1D1 dyn. safety code 1 -D2 dyn. safety code 2 -D3 dyn. safety code 2 -: . D0: dyn. safety code 1 OUT 1. D1: dyn. safety code 1 -. D2: dyn. safety code 2 -. D3: dyn. safety code 2 -. Parameter bits (programmable via AS-i): function. P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their conditionP1not usedP2not usedP3not used: . P0: communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition. P1: not used. P2: not used. P3: not used. UL approval: cULus Listed, Type 1 enclosure. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -25 ... 80 °C (-13 ... 176 °F). Relative humidity: 5 x cable diameter, fixed installation > 10 x cable diameter, movable installation not appropriate for conveyor chainsColorblackCores4 x 0.34 mm2LengthL1 m: . Sheath diameter: ∅4,3 mm. Bending radius: > 5 x cable diameter, fixed installation > 10 x cable diameter, movable installation not appropriate for conveyor chains. Color: black. Cores: 4 x 0.34 mm2. Length: 1 m. Mass: 200 g. Tightening torque, fastening screws: 1.65 Nm. Dimensions: . Height21.5 mmWidth27.7 mmLength40.5 mm: . Height: 21.5 mm. Width: 27.7 mm. Length: 40.5 mm

Specifications

General specifications

Node typeSafety-Slave
AS-Interface specificationV3.0
Required gateway specification≥ V2.1
UL File NumberE223772 "For use in NFPA 79 Applications only"

Indicators/operating means

LED FLTerror display; LED redred: communication error or address is 0
LED AS-iAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0
LED INswitching state (input); 2 LED yellow
LED OUTSwitching state (output); LED yellow

Electrical specifications

Rated operating voltage26.5 ... 31.6 V from AS-Interface (PELV) Ue
Rated operating current≤ 90 mA Ie
Protection classIII
Surge protectionovervoltage category III
Rated insulation voltage32 V
Pulse withstand voltage0.8 kV

Input

Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1
Supplyfrom AS-Interface
Voltage20 ... 30 V DC pulsed
Currentinput current limited ≤ 15 mA,short-circuit protected

Output

Number/Type1 conventional electronic output, PNP
Supplyfrom AS-Interface
Voltage(UASI - 7.0 V) ≤ UOUT ≤ UASI
Current50 mA , short-circuit/overload protected

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 Directive 2014/30/EU
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007
Machinery Directive
Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 Directive 2006/42/EC
Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015

Standard conformity

Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
Electrical safetyIEC 61140:2009
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityIEC 62026-2:2013 EN 62061:2005 EN 61000-6-2:2005
Functional safetyEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015

Programming instructions

ProfileS-7.B
IO code7
ID codeB
ID1 codeF
ID2 code0
Data bits (function via AS-Interface)InputOutput
D0 dyn. safety code 1 OUT 1D1 dyn. safety code 1 -D2 dyn. safety code 2 -D3 dyn. safety code 2 - D0
D0dyn. safety code 1 OUT 1
D1dyn. safety code 1 -
D2dyn. safety code 2 -
D3dyn. safety code 2 -
Parameter bits (programmable via AS-i)function
P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their conditionP1not usedP2not usedP3not used P0
P0communication monitoringP0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1not used
P2not used
P3not used

Approvals and certificates

UL approvalcULus Listed, Type 1 enclosure

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-25 ... 80 °C (-13 ... 176 °F)
Relative humidity< 95 %
Altitude≤ 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree3

Mechanical specifications

Degree of protectionIP67This protection class is achieved by using the AS-Interface flat cable VAZ-FK-S-YE
ConnectionAS-Interface: AS-Interface flat cable Inputs/outputs: open conductor ends
Material
Contactsopen conductor ends with connector sleevesHousingPBTCablePURMounting screwStainless steel 1.4305 / AISI 303 Contacts
Contactsopen conductor ends with connector sleeves
HousingPBT
CablePUR
Mounting screwStainless steel 1.4305 / AISI 303
Cable
Sheath diameter∅4,3 mmBending radius> 5 x cable diameter, fixed installation > 10 x cable diameter, movable installation not appropriate for conveyor chainsColorblackCores4 x 0.34 mm2LengthL1 m Sheath diameter
Sheath diameter∅4,3 mm
Bending radius> 5 x cable diameter, fixed installation > 10 x cable diameter, movable installation not appropriate for conveyor chains
Colorblack
Cores4 x 0.34 mm2
Length1 m L
Mass200 g
Tightening torque, fastening screws1.65 Nm
Dimensions
Height21.5 mmWidth27.7 mmLength40.5 mm Height
Height21.5 mm
Width27.7 mm
Length40.5 mm
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl Fuchs VAA-2E1A-CB10-SJ/E2J-FLAvailable on requestPepperl Fuchs VAA-2E1A-CB10-SJ/E2J-FL
MPN: VAA-2E1A-CB10-SJ/E2J-FL · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs VAA-2E1A-F85A/CB10-S-V1Available on requestPepperl Fuchs VAA-2E1A-F85A/CB10-S-V1
MPN: VAA-2E1A-F85A/CB10-S-V1 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs VAA-2E1A-G10-SAJ/EA2J-1MAvailable on requestPepperl Fuchs VAA-2E1A-G10-SAJ/EA2J-1M
MPN: VAA-2E1A-G10-SAJ/EA2J-1M · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs VAA-2E1A-G10-SAJ/EA2J-2M-V1-GAvailable on requestPepperl Fuchs VAA-2E1A-G10-SAJ/EA2J-2M-V1-G
MPN: VAA-2E1A-G10-SAJ/EA2J-2M-V1-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs VAA-2E1A-IER1-S-1M-V1Available on requestPepperl Fuchs VAA-2E1A-IER1-S-1M-V1
MPN: VAA-2E1A-IER1-S-1M-V1 · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs VAA-2E2A-CB10-SJ/E2J-FLAvailable on requestPepperl Fuchs VAA-2E2A-CB10-SJ/E2J-FL
MPN: VAA-2E2A-CB10-SJ/E2J-FL · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs VAA-2E2A-G12-SAJ/EA2LAvailable on requestPepperl Fuchs VAA-2E2A-G12-SAJ/EA2L
MPN: VAA-2E2A-G12-SAJ/EA2L · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs VAA-2E2A-IM1-J-S-V1Available on requestPepperl Fuchs VAA-2E2A-IM1-J-S-V1
MPN: VAA-2E2A-IM1-J-S-V1 · Pepperl Fuchs
Price on request
Request a quote