Pepperl Fuchs VAA-2E2A-CB10-SJ/E2J-FL
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Safety at Work |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VAA-2E2A-CB10-SJ/E2J-FL be shipped?
VAA-2E2A-CB10-SJ/E2J-FL is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VAA-2E2A-CB10-SJ/E2J-FL in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VAA-2E2A-CB10-SJ/E2J-FL and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VAA-2E2A-CB10-SJ/E2J-FL, subject to availability and destination.
AS-Interface safety module. CB10 safety module, 2 safety-related inputs and 2 conventional electronic outputs. Node type: Safety-Slave. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.1. UL File Number: E223772. LED FAULT: error display; LED redred: communication error or address is 0. LED PWR: AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0. LED IN: switching state (input); 2 LED yellow. LED OUT: Switching state (output); 2 LED yellow. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface (PELV). Rated operating current: ≤ 40 mA (without inputs/outputs)/max. 160 mA. Protection class: III. Surge protection: Ue: Over voltage category III, safe isolated power supplies (PELV). Rated insulation voltage: 32 V. Pulse withstand voltage: 0.8 kV. Number/Type: 2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: Up to category 2/PLc in accordance with ISO 13849-1 or SIL 1 in accordance with IEC 62061 1 two-channel contact: Up to category 4/PLe in accordance with ISO 13849-1 or SIL 3 in accordance with IEC 62061. Supply: from AS-Interface. Voltage: 20 ... 30 V DC pulsed. Current: input current limited ≤ 15 mA,short-circuit protected. Number/Type: 2 conventional electronic outputs, PNP , overload and short-circuit resistant. Supply: from AS-Interface. Voltage: (UASI - 7.0 V) ≤ UOUT ≤ UASI. Current: ≤ 100 mA per output, ≤ 100 mA total. Electromagnetic compatibility: . Directive 2014/30/EUIEC 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 EN 61326-1:2013: . Directive 2014/30/EU: IEC 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 EN 61326-1:2013. Machinery Directive: . Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015: . Directive 2006/42/EC: EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Electrical safety: IEC 61140:2009. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: IEC 62026-2:2013 EN 61326-3-1:2017 EN 61000-6-2:2005. Functional safety: EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015. Profile: S-7.B. IO code: 7. ID code: B. ID1 code: F. ID2 code: 0. Data bits (function via AS-Interface): InputOutput. D0 dyn. safety code 1 OUT 1D1 dyn. safety code 1 OUT 2D2 dyn. safety code 2 -D3 dyn. safety code 2 -: . D0: dyn. safety code 1 OUT 1. D1: dyn. safety code 1 OUT 2. D2: dyn. safety code 2 -. D3: dyn. safety code 2 -. Parameter bits (programmable via AS-i): function. P0not usedP1not usedP2not usedP3not used: . P0: not used. P1: not used. P2: not used. P3: not used. UL approval: Protection class IP20 is not included in the UL approval. The protection class is tested by Pepperl+Fuchs.. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 5000 m above MSL. Shock and impact resistance: 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks. Vibration resistance: 0.35 mm 10 ... 57 Hz , 5 g 57 ... 2000 Hz, 10 cycles. Pollution degree: 2. Degree of protection: IP20 according to EN 60529. Connection: 200 mm, PVC cable 0.5 mm2. Material: . Contactsopen conductor ends with connector sleevesHousingPolyamide hot-melt adhesive: . Contacts: open conductor ends with connector sleeves. Housing: Polyamide hot-melt adhesive. Mass: 31 g. Dimensions: . Height10.1 mmWidth36 mmLength39.5 mm: . Height: 10.1 mm. Width: 36 mm. Length: 39.5 mm. Note: This device is maintenance-free. If the device is used in a manner not specified by the manufaturer, the protection provided by the device may be impaired.
Specifications
General specifications
| Node type | Safety-Slave |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V2.1 |
| UL File Number | E223772 |
Indicators/operating means
| LED FAULT | error display; LED redred: communication error or address is 0 |
| LED PWR | AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 |
| LED IN | switching state (input); 2 LED yellow |
| LED OUT | Switching state (output); 2 LED yellow |
Electrical specifications
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface (PELV) Ue |
| Rated operating current | ≤ 40 mA (without inputs/outputs)/max. 160 mA Ie |
| Protection class | III |
| Surge protection | Ue: Over voltage category III, safe isolated power supplies (PELV) |
| Rated insulation voltage | 32 V |
| Pulse withstand voltage | 0.8 kV |
Input
| Number/Type | 2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: Up to category 2/PLc in accordance with ISO 13849-1 or SIL 1 in accordance with IEC 62061 1 two-channel contact: Up to category 4/PLe in accordance with ISO 13849-1 or SIL 3 in accordance with IEC 62061 |
| Supply | from AS-Interface |
| Voltage | 20 ... 30 V DC pulsed |
| Current | input current limited ≤ 15 mA,short-circuit protected |
Output
| Number/Type | 2 conventional electronic outputs, PNP , overload and short-circuit resistant |
| Supply | from AS-Interface |
| Voltage | (UASI - 7.0 V) ≤ UOUT ≤ UASI |
| Current | ≤ 100 mA per output, ≤ 100 mA total |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUIEC 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 EN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | IEC 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 EN 61326-1:2013 |
| Machinery Directive | |
| Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 | Directive 2006/42/EC |
| Directive 2006/42/EC | EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Electrical safety | IEC 61140:2009 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | IEC 62026-2:2013 EN 61326-3-1:2017 EN 61000-6-2:2005 |
| Functional safety | EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
Programming instructions
| Profile | S-7.B |
| IO code | 7 |
| ID code | B |
| ID1 code | F |
| ID2 code | 0 |
| Data bits (function via AS-Interface) | InputOutput |
| D0 dyn. safety code 1 OUT 1D1 dyn. safety code 1 OUT 2D2 dyn. safety code 2 -D3 dyn. safety code 2 - | D0 |
| D0 | dyn. safety code 1 OUT 1 |
| D1 | dyn. safety code 1 OUT 2 |
| D2 | dyn. safety code 2 - |
| D3 | dyn. safety code 2 - |
| Parameter bits (programmable via AS-i) | function |
| P0not usedP1not usedP2not usedP3not used | P0 |
| P0 | not used |
| P1 | not used |
| P2 | not used |
| P3 | not used |
Approvals and certificates
| UL approval | Protection class IP20 is not included in the UL approval. The protection class is tested by Pepperl+Fuchs. |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 5000 m above MSL |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks |
| Vibration resistance | 0.35 mm 10 ... 57 Hz , 5 g 57 ... 2000 Hz, 10 cycles |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP20 according to EN 60529 |
| Connection | 200 mm, PVC cable 0.5 mm2 |
| Material | |
| Contactsopen conductor ends with connector sleevesHousingPolyamide hot-melt adhesive | Contacts |
| Contacts | open conductor ends with connector sleeves |
| Housing | Polyamide hot-melt adhesive |
| Mass | 31 g |
| Dimensions | |
| Height10.1 mmWidth36 mmLength39.5 mm | Height |
| Height | 10.1 mm |
| Width | 36 mm |
| Length | 39.5 mm |
| Note | This device is maintenance-free. If the device is used in a manner not specified by the manufaturer, the protection provided by the device may be impaired. |