Cold plate or feed-through mounting Parts
























Compare Cold plate or feed-through mounting
Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.
| MPN | DC bus capacitance | Reduction of continuous current depending on installation elevation – Starting at 500 m above sea level | Peak current | Energy efficiency (IE classification) – Nominal losses in standby mode | Weight |
|---|---|---|---|---|---|
| 8BVI0014HCSS.000-1 | 165 µF | 0.19 A eff per 1000 m | 4.7 A eff | 8.3 W | Approx. 2.1 kg |
| 8BVI0028HCSA.000-1 | 165 µF | 0.38 A eff per 1000 m | 9.5 A eff | 8.5 W | Approx. 2.1 kg |
| 8BVI0028HCSS.000-1 | 165 µF | 0.38 A eff per 1000 m | 9.5 A eff | 8.3 W | Approx. 2.1 kg |
| 8BVI0055HCSS.000-1 | 165 µF | 0.76 A eff per 1000 m | 18.9 A eff | 8.3 W | Approx. 2.2 kg |
| 8BVI0110HCSS.000-1 | 330 µF | 1.51 A eff per 1000 m | 37.7 A eff | 8.3 W | Approx. 2.4 kg |
| 8BVI0220HCSS.000-1 | 495 µF | 2.2 A eff per 1000 m | 55 A eff | 11.3 W | Approx. 3.9 kg |
| 8BVI0330HCSS.000-1 | 990 µF | 3.3 A eff per 1000 m | 83 A eff | 11 W | Approx. 4.3 kg |
| 8BVI0440HCSS.000-1 | 990 µF | 4.4 A eff per 1000 m | 88 A eff | 11 W | Approx. 4.3 kg |
| 8BVI0660HCSS.000-1 | 1980 µF | 6.6 A eff per 1000 m | 132 A eff | 11.3 W | Approx. 8 kg |
| 8BVI0880HCSS.004-1 | 1980 µF | 8.8 A eff per 1000 m | 176 A eff | 11.3 W | Approx. 8 kg |
| 8BVI1650HCSS.000-1 | 3630 µF | 16.5 A eff per 1000 m | 330 A eff | 14.3 W | Approx. 19.5 kg |
| 8BVI1650HCSS.004-1 | 3630 µF | 16.5 A eff per 1000 m | 330 A eff | 15 W | 17 kg |
| 8BVI0660HCSA.008-1 | 1980 µF | 6.6 A eff per 1000 m | 132 A eff | 11.3 W | Approx. 7.75 kg |
| 8BVI0660HCSS.008-1 | 1980 µF | 6.6 A eff per 1000 m | 132 A eff | 11.3 W | Approx. 7.75 kg |
| 8BVI0880HCSA.008-1 | 1980 µF | 8.8 A eff per 1000 m | 176 A eff | 11.3 W | Approx. 7.65 kg |
| 8BVI0880HCSS.008-1 | 1980 µF | 8.8 A eff per 1000 m | 176 A eff | 11.3 W | Approx. 7.8 kg |
| 8BVI0110HCSS.000-4 | 330 µF | 1.51 A eff per 1000 m | 37.7 A eff | 9.3 W | Approx. 2.4 kg |
| 8BVI0220HCSS.000-4 | 495 µF | 2.2 A eff per 1000 m | 55 A eff | 12.3 W | Approx. 3.9 kg |
| 8BVI0440HCSS.000-4 | 990 µF | 4.4 A eff per 1000 m | 88 A eff | 12 W | Approx. 4.3 kg |
| 8BVI0880HCSS.008-4 | 1980 µF | 8.8 A eff per 1000 m | 176 A eff | 12.3 W | Approx. 7.8 kg |
| 8BVI1650HCSS.004-4 | 3630 µF | 16.5 A eff per 1000 m | 330 A eff | 16 W | 17 kg |
| 8BVI0014HCSS.000-4 | 165 µF | 0.19 A eff per 1000 m | 4.7 A eff | 9.3 W | Approx. 2.1 kg |
| 8BVI0028HCSS.000-4 | 165 µF | 0.38 A eff per 1000 m | 9.5 A eff | 9.3 W | Approx. 2.1 kg |
| 8BVI0055HCSS.000-4 | 165 µF | 0.76 A eff per 1000 m | 18.9 A eff | 9.3 W | Approx. 2.2 kg |
Common to all listed parts
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – Functional safety | Yes (openSAFETY) |
| Certifications – UL | cULus E225616; Power conversion equipment |
| Cooling and mounting type | Cold plate or pass-through mounting |
| Voltage – Nominal | 750 VDC |
| Variant | ACOPOSmulti backplane |
| Input voltage | 25 VDC ±1.6% |