Quick facts

AvailabilityConfirmed on request
CategoryCold plate or feed-through mounting
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)
DatasheetManufacturer datasheet ↗

Shipping & availability

When can 8BVI1650HCSS.000-1 be shipped?

8BVI1650HCSS.000-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 8BVI1650HCSS.000-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 8BVI1650HCSS.000-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8BVI1650HCSS.000-1, subject to availability and destination.

• Clearly structured, straightforward implementation via network-based safety technology

• Modular expandability through virtual wiring

• Immediate triggering of safety function due to short cycle times

• Easy implementation with transparent control and status information, even in the standard application

• Compact construction, complete functionality of safety functions, even in dual-axis modules

ACOPOSmulti SafeMOTION EnDat 2.2 inverter module, 165 A, AS, cold plate or pass-through mounting

Accessories

Required accessories (order separately)

8BZVI1650SS.000-1ATerminal block sets — Screw clamp terminal block set for ACOPOSmulti 8BVI0660HxSS, 8BVI0880HxSS, 8BVI1650HxSS, 8BVI0660HxSA, 8BVI0880HxSA and 8BVI1650HxSA module…
Optional accessories (28)
8BXB000.0000-00Accessory sets — ACOPOSmulti accessory set for encoder buffering consisting of: 1x battery AA 3.6 V, 1x protective cover for battery holder
8BXF001.0000-00Fan modules — ACOPOSmulti fan module, replacement fan for ACOPOSmulti modules (8BxP/8B0C/8BVI/8BVE/8B0K)
X20CA0E61.00100POWERLINK/Ethernet cables — POWERLINK/Ethernet connection cable, RJ45 to RJ45, 1 m
X20CA0E61.00050POWERLINK/Ethernet cables — POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.5 m
X20CA0E61.00035POWERLINK/Ethernet cables — POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.35 m
X20CA0E61.00030POWERLINK/Ethernet cables — POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.3 m
X20CA0E61.00025POWERLINK/Ethernet cables — POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.25 m
X20CA0E61.00020POWERLINK/Ethernet cables — POWERLINK/Ethernet connection cable, RJ45 to RJ45, 0.2 m
8BAC0133.000-1Plug-in modules — Encoder emulation module for installation in ACOPOSmulti modules; 3 RS422 outputs; ABR encoder emulation ACOPOSmulti plug-in module, 3 RS42…
8BAC0132.000-1Plug-in modules — Analog input module for installation in ACOPOSmulti modules; 4 high-speed analog inputs ±10 V ACOPOSmulti plug-in module, 4 analog inputs ±…
8BAC0130.001-1Plug-in modules — Digital output module for installation in ACOPOSmulti modules; 2 high-speed outputs, +24 VDC; 2 standard readable outputs, +24 VDC ACOPOSmu…
8BAC0130.000-1Plug-in modules — Digital mixed module for installation in ACOPOSmulti modules; 2 inputs, +24 VDC; 2 high-speed outputs, +24 VDC; 2 standard readable outputs…
8BAC0125.000-1Plug-in modules — Interface for evaluating sinusoidal output signals; Functions and protocols selected through configuration (using a higher-level controller…
8BAC0124.000-1Plug-in modules — SinCos interface for installation in ACOPOSmulti modules; Evaluation of incremental encoders with sinusoidal output signal; Encoder supply…
8BAC0123.002-1Plug-in modules — Incremental encoder interface for installation in ACOPOSmulti modules; Evaluation of incremental encoders with push, pull or push-pull outp…
8BAC0123.001-1Plug-in modules — Incremental encoder interface for installation in ACOPOSmulti modules; Evaluation of incremental encoders with push, pull or push-pull outp…
8BAC0123.000-1Plug-in modules — Incremental encoder and SSI absolute encoder interface for installation in ACOPOSmulti modules; Evaluation of incremental/SSI encoders with…
8BAC0122.000-1Plug-in modules — Resolver interface for installation in ACOPOSmulti modules; Encoder monitoring; High resolution ACOPOSmulti plug-in module, resolver interf…
8BAC0121.000-1Plug-in modules — HIPERFACE interface for installation in ACOPOSmulti modules; Encoder monitoring; High resolution ACOPOSmulti plug-in module, HIPERFACE inte…
8BAC0120.001-2Plug-in modules — EnDat 2.2 encoder interface for installation in ACOPOSmulti modules; Encoder monitoring; Embedded parameter chip when used with B&R motors…
8BAC0120.000-1Plug-in modules — EnDat 2.1 encoder interface for installation in ACOPOSmulti modules; Encoder monitoring; High-precision analog signal processing; Embedded…
8SCS010.0000-00Shield component sets — ACOPOSmulti shield component set: 1x ACOPOSmulti holding plate SK14-20, 1x shield connection clamp SK20
8SCS004.0000-00Shield component sets — ACOPOSmulti shield component set: 1x shield plate 4x type 0, 2x hose clamps, B 9 mm, D 32-50 mm
8SCS003.0000-00Shield component sets — ACOPOSmulti shield component set: 1x shield mounting plate 4x 45°, 8x screws
8SCS002.0000-00Shield component sets — ACOPOSmulti shield component set: 1x clamping plate, 2x clamp D 4-13.5 mm, 2x screws
8SCS001.0000-00Shield component sets — ACOPOSmulti shield component set: 1x shield plate 4x type 1, 1x hose clamp, B 9 mm, D 12-22 mm
8TB2108.2010-00Terminal blocks — 8-pin screw clamp terminal block, 1-row, pitch: 5.08 mm, label 1: Numbered consecutively
8TB2104.203L-00Terminal blocks — 4-pin screw clamp terminal block, 1-row, pitch: 5.08 mm, label 3: T- T+ B- B+, coding L: 1010

Specifications

General information

Support – Dynamic node allocation (DNA)Yes
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)Evaluation ongoing
Certifications – Functional safetyYes (openSAFETY)
Certifications – ULcULus E225616; Power conversion equipment
Certifications – KCYes
B&R ID code0xB878
Cooling and mounting typeCold plate or pass-through mounting
Slots for plug-in modules2 " data-placement="top" data-html="true" data-container="body" data-content="SLOT 2 is available. SLOT 1 of the ACOPOSmulti module is occupied by the SafeMOTION module.">

DC bus connection

Voltage – Nominal750 VDC
Power dissipation depending on switching frequency " data-placement="top" data-html="true" data-container="body" data-content="I<sub>M</sub> ... Current on motor connection X5A [A<sub>eff</sub>]"> – Switching frequency 5 kHz[0.001 * I M ² + 9.9 * I M + 165] W
Power dissipation depending on switching frequency " data-placement="top" data-html="true" data-container="body" data-content="I<sub>M</sub> ... Current on motor connection X5A [A<sub>eff</sub>]"> – Switching frequency 10 kHz[0.17 * I M ² + 10.8 * I M + 320] W
Power dissipation depending on switching frequency " data-placement="top" data-html="true" data-container="body" data-content="I<sub>M</sub> ... Current on motor connection X5A [A<sub>eff</sub>]"> – Switching frequency 20 kHzIn preparation
Continuous power consumption " data-placement="top" data-html="true" data-container="body" data-content="Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40&#xB0;C ambient temperature, installation elevation &lt;500 m above sea level, no derating due to cooling type.">121.8 kW
DC bus capacitance3630 µF
VariantACOPOSmulti backplane

24 VDC power supply

Input voltage25 VDC ±1.6%
Input capacitance32.9 µF
Max. power consumption43 W + P SMC1 + P SLOT2 + P 24 V Out + P HoldingBrake " data-placement="top" data-html="true" data-container="body" data-content="P<sub>SMC1</sub> ... Max. power consumption P<sub>SMC</sub> [W] of the SafeMOTION module in SLOT1 (see section "Encoder interfaces"). <br>P<sub>SLOT2</sub> ... Max. power consumption P<sub>8BAC</sub> [W] of the plug-in module in SLOT2 (see the technical data for the respective plug-in module). <br>P<sub>24 V Out</sub> ... Power [W] that is output to connections X2/+24 V Out 1 and X2/+24 V Out 2 on the module (max. 10 W).">
VariantACOPOSmulti backplane

24 VDC output

Output voltage – DC bus voltage (U DC ): 260 to 315 VDC25 VDC * (U DC /315)
Output voltage – DC bus voltage (U DC ): 315 to 800 VDC24 VDC ±6%
Quantity2
Fuse protection250 mA (slow-blow) electronic, automatic reset

Motor connection " data-placement="top" data-html="true" data-container="body" data-content="Only B&amp;R 8BCM motor cables are permitted to be used for wiring the motor connections!">

Reduction of continuous current depending on switching frequency and mounting type " data-placement="top" data-html="true" data-container="body" data-content="Valid under the following conditions: 750 VDC DC bus voltage, minimum permissible coolant flow volume (3 l/min)."> – Cold plate mounting " data-placement="top" data-html="true" data-container="body" data-content="The temperature specifications refer to the return temperature of the cold plate mounting plate.">3.1 A/K (starting at 53°C) " data-placement="top" data-html="true" data-container="body" data-content="Value for the nominal switching frequency.">
Reduction of continuous current depending on switching frequency and mounting type " data-placement="top" data-html="true" data-container="body" data-content="Valid under the following conditions: 750 VDC DC bus voltage, minimum permissible coolant flow volume (3 l/min)."> – Pass-through mounting2.82 A/K (starting at 40°C) " data-placement="top" data-html="true" data-container="body" data-content="Value for the nominal switching frequency.">
Reduction of continuous current depending on switching frequency and mounting type " data-placement="top" data-html="true" data-container="body" data-content="Valid under the following conditions: 750 VDC DC bus voltage, minimum permissible coolant flow volume (3 l/min)."> – Cold plate mounting " data-placement="top" data-html="true" data-container="body" data-content="The temperature specifications refer to the return temperature of the cold plate mounting plate.">1.8 A/K (starting at 17°C) " data-placement="top" data-html="true" data-container="body" data-content="The module cannot supply the full continuous current at this switching frequency. This unusual value for the return temperature, at which derating of the continuous current must be taken into account, ensures that the derating of the continuous current can be determined in the same manner as at other switching frequencies. <br>Caution! Condensation can occur at low flow temperatures and return temperatures.">
Reduction of continuous current depending on switching frequency and mounting type " data-placement="top" data-html="true" data-container="body" data-content="Valid under the following conditions: 750 VDC DC bus voltage, minimum permissible coolant flow volume (3 l/min)."> – Pass-through mounting1.5 A/K (starting at -13°C) " data-placement="top" data-html="true" data-container="body" data-content="The module cannot supply the full continuous current at this switching frequency. This unusual value for the ambient temperature, at which derating of the continuous current must be taken into account, ensures that the derating of the continuous current can be determined in the same manner as at other switching frequencies.">
Reduction of continuous current depending on switching frequency and mounting type " data-placement="top" data-html="true" data-container="body" data-content="Valid under the following conditions: 750 VDC DC bus voltage, minimum permissible coolant flow volume (3 l/min)."> – Cold plate mounting " data-placement="top" data-html="true" data-container="body" data-content="The temperature specifications refer to the return temperature of the cold plate mounting plate.">1.2 A/K (starting at -60°C) " data-placement="top" data-html="true" data-container="body" data-content="The module cannot supply the full continuous current at this switching frequency. This unusual value for the return temperature, at which derating of the continuous current must be taken into account, ensures that the derating of the continuous current can be determined in the same manner as at other switching frequencies. <br>Caution! Condensation can occur at low flow temperatures and return temperatures.">
Reduction of continuous current depending on switching frequency and mounting type " data-placement="top" data-html="true" data-container="body" data-content="Valid under the following conditions: 750 VDC DC bus voltage, minimum permissible coolant flow volume (3 l/min)."> – Pass-through mounting0.72 A/K (starting at 141°C) " data-placement="top" data-html="true" data-container="body" data-content="The module cannot supply the full continuous current at this switching frequency. This unusual value for the ambient temperature, at which derating of the continuous current must be taken into account, ensures that the derating of the continuous current can be determined in the same manner as at other switching frequencies.">
Reduction of continuous current depending on installation elevation – Starting at 500 m above sea level16.5 A eff per 1000 m
Protective measures – Overload protectionYes
Protective measures – Short-circuit and ground fault protectionYes
Variant – U, V, W, PEM8 threaded bolts
Variant – Shield connectionYes
Connection cross section range – Flexible and fine-stranded wires--- " data-placement="top" data-html="true" data-container="body" data-content="The connection is made with cable lugs for M8 (0.32") threaded bolts. The nominal cross section of the cable lug must match the cross section of the conductor to be connected in the particular application.">
Max. motor line length depending on switching frequency – Switching frequency 5 kHz25 m
Max. motor line length depending on switching frequency – Switching frequency 10 kHz25 m
Max. motor line length depending on switching frequency – Switching frequency 20 kHz25 m
Quantity1
Continuous power per motor connection " data-placement="top" data-html="true" data-container="body" data-content="Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40&#xB0;C ambient temperature, installation elevation &lt;500 m above sea level, no derating due to cooling type.">120 kW
Continuous current per motor connection " data-placement="top" data-html="true" data-container="body" data-content="Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40&#xB0;C ambient temperature, installation elevation &lt;500 m above sea level, no derating due to cooling type.">165 A eff
Peak current330 A eff
Nominal switching frequency5 kHz
Possible switching frequencies " data-placement="top" data-html="true" data-container="body" data-content="B&amp;R recommends operating the module at its nominal switching frequency. Operating the module at a higher switching frequency for application-specific reasons reduces the continuous current and increases CPU utilization.">5 / 10 / 20 kHz
Insulation stress of the connected motor per IEC TS 60034-25:2004 " data-placement="top" data-html="true" data-container="body" data-content="If necessary, the stress of the motor isolation system can be reduced by an additional externally wired dv/dt choke. For example, the RWK 305 three-phase dv/dt choke from Schaffner (www.schaffner.com) can be used. IMPORTANT: Even when using a dv/dt choke, it is necessary to ensure that an EMC-compatible, low inductance shield connection is used!">Limit value curve A " data-placement="top" data-html="true" data-container="body" data-content="Only applies when using B&amp;R motor cables and B&amp;R motors.">
Max. output frequency598 Hz " data-placement="top" data-html="true" data-container="body" data-content="The module's electrical output frequency (SCTRL_SPEED_ACT * MOTOR_POLEPAIRS) is monitored to protect against dual use in accordance with Regulation (EC) 428/2009 | 3A225. If the electrical output frequency of the module exceeds the limit value of 598 Hz uninterrupted for more than 0.5 s, then the current movement is aborted and error 6060 is output ("Power unit: Limit speed exceeded").">
Terminal cable cross section dimension of shield connection12 to 50 mm " data-placement="top" data-html="true" data-container="body" data-content="The maximum diameter that can be clamped depends on the shield component set.">

Motor holding brake connection

Protective measures – Overload and short-circuit protectionYes
Protective measures – Open-circuit monitoringYes
Protective measures – Undervoltage monitoringYes
Quantity1
Output voltage " data-placement="top" data-html="true" data-container="body" data-content="During configuration, it is necessary to check if the minimum voltage can be maintained on the holding brake with the intended wiring. For the operating voltage range of the holding brake, see the user documentation for the motor being used.">24 VDC +5.8% / -0.5% " data-placement="top" data-html="true" data-container="body" data-content="The specified value is only valid under the following conditions: <br>- The 24 VDC power supply for the module is provided by an 8B0C auxiliary supply module located on the same mounting plate. <br>- Connection of connectors S1 and S2 (activation of the external holding brake) by a jumper with a maximum length of 10 cm. <br>If the 24 VDC power supply for the module is applied to the mounting plate using an 8BVE expansion module, then the output voltage is reduced because of voltage drops on the expansion cable. In this case, undervoltage monitoring must be disabled. <br>If jumpers longer than 10 cm are used to connect connectors S1 and S2, then the output voltage is reduced due to voltage drops on the jumpers.">
Continuous current per connection4.2 A
Max. internal resistance0.15 Ω
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation3 Ws
Max. switching frequency0.5 Hz
Response threshold for open-circuit monitoringApprox. 0.5 A
Response threshold for undervoltage monitoring24 VDC -2% / -4%

Encoder interfaces " data-placement="top" data-html="true" data-container="body" data-content="Only B&amp;R 8BCF EnDat 2.2 cables are permitted to be used for wiring the encoder interfaces.">

Electrical isolation – Encoder - ACOPOSmultiNo
Encoder power supply – Short-circuit proofYes
Encoder power supply – Overload-proofYes
Encoder power supply – Output voltageTyp. 12.5 V
Encoder power supply – Load capacity350 mA
Synchronous serial interface – Signal transmissionRS485
Synchronous serial interface – Data transfer rate6.25 Mbit/s
Quantity1
TypeEnDat 2.2 " data-placement="top" data-html="true" data-container="body" data-content="An EnDat 2.2 functional safety encoder is required when using ACOPOSmulti SafeMOTION inverter modules! With standard EnDat 2.2 encoders, only the STO, SBC and time-monitored SS1 safety functions are available!">
Connections9-pin female DSUB connector
Status indicatorsUP/DN LEDs
Encoder monitoringYes
Max. encoder cable length100 m ; Depends on the cross section of the power supply wires in the encoder cable " data-placement="top" data-html="true" data-container="body" data-content="Maximum encoder cable length l<sub>max</sub> can be calculated as follows (the maximum permissible encoder cable length of 100 m is not permitted to be exceeded): <br><br>l<sub>max</sub> = 7.9 / I<sub>G</sub> * A * 1/(2*&#x3C1;) <br><br>I<sub>G</sub> ... Max. current consumption of the encoder [A]. <br>A ... Cross section of the power supply wires [mm&#xB2;] <br>&#x3C1; ... Specific resistance [&#x2126; mm&#xB2;/m] (e.g. for copper: &#x3C1; = 0.0178)">
Max. power consumption per encoder interfaceP SMC [W] = 19 V * I Encoder [A] " data-placement="top" data-html="true" data-container="body" data-content="I<sub>Encoder</sub> ... Max. current consumption of the connected encoder [A].">

Trigger inputs

Electrical isolation – Input - Inverter moduleYes
Electrical isolation – Input - InputYes
Input voltage – Nominal24 VDC
Input voltage – Maximum30 VDC
Switching threshold – Low<5 V
Switching threshold – High>15 V
Switching delay – Rising edge52 µs ±0.5 µs (digitally filtered)
Switching delay – Falling edge53 µs ±0.5 µs (digitally filtered)
Quantity2
CircuitSink
Input current at nominal voltageApprox. 10 mA
Modulation compared to ground potentialMax. ±38 V

Temperature sensor connection

Quantity1
Resistance range500 Ω to 5 kΩ

Electrical properties

Energy efficiency (IE classification) " data-placement="top" data-html="true" data-container="body" data-content="The IE classification of the module is based on drive losses. This includes components such as EMC filters, etc. The power dissipation was determined at a switching frequency of 5 kHz (factory setting). Classification is performed at 90% of the frequency and at 100% of the continuous current. When operating the module in connection with an induction motor, the module is only permitted to be operated with a switching frequency of 5 kHz."> – Power dissipation relative to continuous apparent power " data-placement="top" data-html="true" data-container="body" data-content="Continuous apparent power S[VA] = &#x221A;3 * UMains[Vrms] * IMains[Arms]. IE2 notation (a,b) stands respectively for a load point with frequency a (as a percentage of the nominal frequency of the motor) and current b (as a percentage of the continuous current).">IE2 (10,25) 0.7% ; IE2 (50,25) 0.7% ; IE2 (10,50) 0.9% ; IE2 (50,50) 0.9% ; IE2 (90,50) 0.9% ; IE2 (10,100) 1.6% ; IE2 (50,100) 1.6% ; IE2 (90,100) 1.7%
Energy efficiency (IE classification) " data-placement="top" data-html="true" data-container="body" data-content="The IE classification of the module is based on drive losses. This includes components such as EMC filters, etc. The power dissipation was determined at a switching frequency of 5 kHz (factory setting). Classification is performed at 90% of the frequency and at 100% of the continuous current. When operating the module in connection with an induction motor, the module is only permitted to be operated with a switching frequency of 5 kHz."> – Nominal losses in standby mode14.3 W
Discharge capacitance0.9 µF

Operating conditions

Permissible mounting orientations – Hanging verticallyYes
Permissible mounting orientations – Horizontal, face upYes
Permissible mounting orientations – Standing horizontallyNo
Installation elevation above sea level – Nominal0 to 500 m
Installation elevation above sea level – Maximum " data-placement="top" data-html="true" data-container="body" data-content="Continuous operation at an installation elevation of 500 m to 4,000 m above sea level is possible taking the specified reduction of continuous current into account.">4000 m
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Degree of protection per EN 60529IP20 " data-placement="top" data-html="true" data-container="body" data-content="This value only applies in its delivered state (SLOT2 of the module is sealed by a slot cover / shield plate). If SLOT2 on the module is not sealed, then the level of protection is reduced to IP10. It is important to note that a 8SCS005.0000-00 shield set (slot cover / shield plate) or plug-in module must always be inserted!">

Ambient conditions

Temperature – Nominal5 to 40°C
Temperature – Maximum55°C
Temperature – Storage-25 to 55°C
Temperature – Transport-25 to 70°C
Relative humidity – Operation5 to 85%
Relative humidity – Storage5 to 95%
Relative humidity – TransportMax. 95% at 40°C

Mechanical properties

Dimensions " data-placement="top" data-html="true" data-container="body" data-content="These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation."> – Cold plate212 mm
Dimensions " data-placement="top" data-html="true" data-container="body" data-content="These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation."> – Pass-through mounting209 mm
Dimensions " data-placement="top" data-html="true" data-container="body" data-content="These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation."> – Width427.5 mm
Dimensions " data-placement="top" data-html="true" data-container="body" data-content="These dimensions refer to the actual device dimensions including the respective mounting plate. Additional spacing above and below the devices must be taken into account for mounting, connections and air circulation."> – Height317 mm
WeightApprox. 19.5 kg
Module width8

Downloads & documentation

Official documents from B&R, downloaded directly from the manufacturer.

Data sheets & manuals

Datasheet 8BVI1650HCSS.000-1PDF · 3 MB · 1.3 (10/17/2014) - EN
Integrated safety technology user's manualPDF · 46 MB · 6.8.0 (09/02/2026) - EN
SafeMOTION User´s ManualPDF · 35 MB · 4.9.2.1 (05/08/2026) - EN

CAD & dimension drawings

3D file STEP 8BVI1650HCSS.00x-xZIP · 418 KB · 1.1 (04/23/2024)
Certificates (3)
ACOPOSmulti KC certificatesZIP · 3 MB · 1.10 (03/18/2024)
E225616 UL Certificate of Compliance ACOPOSmulti (UL 508C)PDF · 282 KB · 1.30 (07/20/2022)
TÜV-Certificate - Functional Safety ACOPOSmulti SafeMOTION EnDat 2.2ZIP · 633 KB · 3.00 (10/15/2025) - EN
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More B&R parts

B&R 8BVI0880HWSS.008-4 – ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter moduleAvailable on requestB&R 8BVI0880HWSS.008-4 – ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter module
MPN: 8BVI0880HWSS.008-4 · B&R
Price on request
Request a quote
B&R 8BVI1650HCS0.000-1 – Uncontrolled stops and safe stop integratedAvailable on requestB&R 8BVI1650HCS0.000-1 – Uncontrolled stops and safe stop integrated
MPN: 8BVI1650HCS0.000-1 · B&R
Price on request
Request a quote
B&R 8BVI1650HCS0.004-1 – ACOPOSmulti inverter module, 165 A, ASAvailable on requestB&R 8BVI1650HCS0.004-1 – ACOPOSmulti inverter module, 165 A, AS
MPN: 8BVI1650HCS0.004-1 · B&R
Price on request
Request a quote
B&R 8BVI1650HCS0.004-3 – ACOPOSmulti3 inverter module, 165 A, ASAvailable on requestB&R 8BVI1650HCS0.004-3 – ACOPOSmulti3 inverter module, 165 A, AS
MPN: 8BVI1650HCS0.004-3 · B&R
Price on request
Request a quote
B&R 8BVI1650HCSS.004-1 – ACOPOSmulti inverter module, 165 A, ASAvailable on requestB&R 8BVI1650HCSS.004-1 – ACOPOSmulti inverter module, 165 A, AS
MPN: 8BVI1650HCSS.004-1 · B&R
Price on request
Request a quote
B&R 8BVI1650HCSS.004-4 – ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter moduleAvailable on requestB&R 8BVI1650HCSS.004-4 – ACOPOSmulti3 SafeMOTION EnDat 2.2 Gen2 inverter module
MPN: 8BVI1650HCSS.004-4 · B&R
Price on request
Request a quote
B&R 8BVI1650HWS0.000-1 – Integrated uncontrolled standstill and safe stopAvailable on requestB&R 8BVI1650HWS0.000-1 – Integrated uncontrolled standstill and safe stop
MPN: 8BVI1650HWS0.000-1 · B&R
Price on request
Request a quote
B&R 8BVI1650HWS0.004-1 – ACOPOSmulti inverter module, 165 A, AS, wall mountingAvailable on requestB&R 8BVI1650HWS0.004-1 – ACOPOSmulti inverter module, 165 A, AS, wall mounting
MPN: 8BVI1650HWS0.004-1 · B&R
Price on request
Request a quote