Available on request

Pepperl Fuchs VIM82PL-S1V16-2CE-I422C28

MPN: VIM82PL-S1V16-2CE-I422C28 · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryVibration Sensors
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can VIM82PL-S1V16-2CE-I422C28 be shipped?

VIM82PL-S1V16-2CE-I422C28 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up VIM82PL-S1V16-2CE-I422C28 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for VIM82PL-S1V16-2CE-I422C28 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VIM82PL-S1V16-2CE-I422C28, subject to availability and destination.

Vibration sensor. Vibration sensor with safety function both for the analog current output and for the 2 relay outputs with adjustable switching thresholds, Series: Performance Line, Measured variable: Vibration velocity, Safety Integrity Level (SIL): SIL 2, Output type: relay, Output type: relay, Output type: analog output, current <BR>output of the vibration variable, Equipment protection level Gc: IECEx ULD 22.0031X, Equipment protection level Dc: IECEx ULD 22.0031X, Equipment protection level Gc: UL 22 ATEX 2870 X. Type: Vibration sensor. Measuring technology: MEMS. Series: Performance Line. Measured variable: Vibration velocity. Measuring range: . Vibration velocityv-rms0 ... 16 mm/s: v-rms. Vibration velocity: 0 ... 16 mm/s. Measurement accuracy: ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s. Cross-sensitivity: < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis. Frequency range: 10 ... 1000 Hz. Averaging time: for v-rms: 2 s. Safety Integrity Level (SIL): SIL 2. Performance level (PL): PL d. Category: Cat. 2. MTTFd: 329 a. Mission Time (TM): 10 a. Diagnostic Coverage (DC): min. 90 %. Status indicator: 6 LEDs for operating states. Control elements: 4 rotary switches and 1 push button for programming. Fusing: external fuse is required: 3 A , semi-time-lag , 30 V DC. Operating voltage: 24 V DC + 7 % / - 10 %. Current consumption: max. 100 mA. Power consumption: 2.6 W. Time delay before availability: 15 s (initially self-test functions are executed before safe measured values are available at the output). Surge protection: up to 2 kV. Output type: relay. Switching function: Normally open (NO). Switching voltage: max. 30 V DC. Switching current: max. 1 A. Output type: relay. Switching function: Normally open (NO). Switching voltage: max. 30 V DC. Switching current: max. 1 A. Output type: analog output, current output of the vibration variable. Output current: 4 ... 20 mA. Load resistor: ≤ 500 Ω. Degree of protection: DIN EN 60529, IP66, IP67. Shock resistance: DIN EN 60068-2-27, 60 g, 6 ms. Vibration resistance: DIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz. Vibration evaluation: DIN ISO 10816/20816. Functional safety: DIN EN IEC 61508 , SIL 2 EN ISO 13849 , PL d. IECEx approval: . Equipment protection level GcIECEx ULD 22.0031XEquipment protection level DcIECEx ULD 22.0031X: . Equipment protection level Gc: IECEx ULD 22.0031X. Equipment protection level Dc: IECEx ULD 22.0031X. ATEX approval: . Equipment protection level GcUL 22 ATEX 2870 XEquipment protection level DcUL 22 ATEX 2870 X: . Equipment protection level Gc: UL 22 ATEX 2870 X. Equipment protection level Dc: UL 22 ATEX 2870 X. UL approval: . Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on requestHazardous LocationE106378Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)Control drawing116-0493: . Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request. Hazardous Location: E106378. Maximum permissible ambient temperature: max. 60 °C (max. 140 °F). Control drawing: 116-0493. Ambient temperature: -35 ... 60 °C (-31 ... 140 °F). Measuring head temperature: -35 ... 125 °C (-31 ... 257 °F) directly at the mounting point. Storage temperature: -35 ... 60 °C (-31 ... 140 °F). Connection type: cable. Housing material: Stainless steel 1.4305 / AISI 303. Degree of protection: IP66 / IP67 only in connected state and correctly mounted housing cover. Cable: . Number of cores8LengthL2 m: . Number of cores: 8. Length: 2 m. Mass: 880 g. Dimensions: . Height46 mmWidth62 mmLength77.3 mm: . Height: 46 mm. Width: 62 mm. Length: 77.3 mm. Scope of delivery: 1 x allen head screw M8 x 20 1 x spring washer M8 1 x seal label. Use in the hazardous area: see instruction manuals Only use accessories specified by the manufacturer.

Specifications

General specifications

TypeVibration sensor
Measuring technologyMEMS
SeriesPerformance Line
Measured variableVibration velocity
Measuring range
Vibration velocityv-rms0 ... 16 mm/sv-rms Vibration velocity
Vibration velocity0 ... 16 mm/s v-rms
Measurement accuracy± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s
Cross-sensitivity< 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis
Frequency range10 ... 1000 Hz
Averaging timefor v-rms: 2 s

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
Performance level (PL)PL d
CategoryCat. 2
MTTFd329 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)min. 90 %

Indicators/operating means

Status indicator6 LEDs for operating states
Control elements4 rotary switches and 1 push button for programming

Electrical specifications

Fusingexternal fuse is required: 3 A , semi-time-lag , 30 V DC
Operating voltage24 V DC + 7 % / - 10 % UB
Current consumptionmax. 100 mA
Power consumption2.6 W P0
Time delay before availability15 s (initially self-test functions are executed before safe measured values are available at the output) tv
Surge protectionup to 2 kV

Output 1

Output typerelay
Switching functionNormally open (NO)
Switching voltagemax. 30 V DC
Switching currentmax. 1 A

Output 2

Output typerelay
Switching functionNormally open (NO)
Switching voltagemax. 30 V DC
Switching currentmax. 1 A

Output 3

Output typeanalog output, current output of the vibration variable
Output current4 ... 20 mA
Load resistor≤ 500 Ω

Standard conformity

Degree of protectionDIN EN 60529, IP66, IP67
Shock resistanceDIN EN 60068-2-27, 60 g, 6 ms
Vibration resistanceDIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz
Vibration evaluationDIN ISO 10816/20816
Functional safetyDIN EN IEC 61508 , SIL 2 EN ISO 13849 , PL d

Approvals and certificates

IECEx approval
Equipment protection level GcIECEx ULD 22.0031XEquipment protection level DcIECEx ULD 22.0031X Equipment protection level Gc
Equipment protection level GcIECEx ULD 22.0031X
Equipment protection level DcIECEx ULD 22.0031X
ATEX approval
Equipment protection level GcUL 22 ATEX 2870 XEquipment protection level DcUL 22 ATEX 2870 X Equipment protection level Gc
Equipment protection level GcUL 22 ATEX 2870 X
Equipment protection level DcUL 22 ATEX 2870 X
UL approval
Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on requestHazardous LocationE106378Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)Control drawing116-0493 Ordinary Location
Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request
Hazardous LocationE106378
Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)
Control drawing116-0493

Ambient conditions

Ambient temperature-35 ... 60 °C (-31 ... 140 °F)
Measuring head temperature-35 ... 125 °C (-31 ... 257 °F) directly at the mounting point
Storage temperature-35 ... 60 °C (-31 ... 140 °F)

Mechanical specifications

Connection typecable
Housing materialStainless steel 1.4305 / AISI 303
Degree of protectionIP66 / IP67 only in connected state and correctly mounted housing cover
Cable
Number of cores8LengthL2 m Number of cores
Number of cores8
Length2 m L
Mass880 g
Dimensions
Height46 mmWidth62 mmLength77.3 mm Height
Height46 mm
Width62 mm
Length77.3 mm

General information

Scope of delivery1 x allen head screw M8 x 20 1 x spring washer M8 1 x seal label
Use in the hazardous areasee instruction manuals Only use accessories specified by the manufacturer.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote