Pepperl Fuchs VIM82PP-S1V32-2BE-I422C28
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Vibration Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VIM82PP-S1V32-2BE-I422C28 be shipped?
VIM82PP-S1V32-2BE-I422C28 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VIM82PP-S1V32-2BE-I422C28 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VIM82PP-S1V32-2BE-I422C28 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VIM82PP-S1V32-2BE-I422C28, subject to availability and destination.
Vibration sensor. Vibration sensor with safety function both for the analog current output and for the 2 relay outputs with adjustable switching thresholds, Series: Performance Plus Line, Measured variable: Vibration velocity, Safety Integrity Level (SIL): SIL 2, Output type: relay, Output type: relay, Output type: analog output, current <BR>output of the vibration variable, Equipment protection level Gb: IECEx ULD 22.0031X, Equipment protection level Db: IECEx ULD 22.0031X, Equipment protection level Gb: UL 22 ATEX 2869 X. Type: Vibration sensor. Measuring technology: MEMS. Series: Performance Plus Line. Measured variable: Vibration velocity. Measuring range: . Vibration velocityv-rms0 ... 32 mm/s: v-rms. Vibration velocity: 0 ... 32 mm/s. Measurement accuracy: ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s. Cross-sensitivity: < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis. Frequency range: 10 ... 1000 Hz. Averaging time: for v-rms: 2 s. Safety Integrity Level (SIL): SIL 2. Performance level (PL): PL d. Category: Cat. 2. MTTFd: 329 a. Mission Time (TM): 10 a. Diagnostic Coverage (DC): min. 90 %. Status indicator: 6 LEDs for operating states. Control elements: 4 rotary switches and 1 push button for programming. Fusing: external fuse is required: 3 A , semi-time-lag , 30 V DC. Operating voltage: 24 V DC + 7 % / - 10 %. Current consumption: max. 100 mA. Power consumption: 2.6 W. Time delay before availability: 15 s (initially self-test functions are executed before safe measured values are available at the output). Surge protection: up to 2 kV. Output type: relay. Switching function: Normally open (NO). Switching voltage: max. 30 V DC. Switching current: max. 1 A. Output type: relay. Switching function: Normally open (NO). Switching voltage: max. 30 V DC. Switching current: max. 1 A. Output type: analog output, current output of the vibration variable. Output current: 4 ... 20 mA. Load resistor: ≤ 500 Ω. Degree of protection: DIN EN 60529, IP66, IP67. Shock resistance: DIN EN 60068-2-27, 60 g, 6 ms. Vibration resistance: DIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz. Vibration evaluation: DIN ISO 10816/20816. Functional safety: DIN EN IEC 61508 , SIL 2 EN ISO 13849 , PL d. IECEx approval: . Equipment protection level GbIECEx ULD 22.0031XEquipment protection level DbIECEx ULD 22.0031X: . Equipment protection level Gb: IECEx ULD 22.0031X. Equipment protection level Db: IECEx ULD 22.0031X. ATEX approval: . Equipment protection level GbUL 22 ATEX 2869 XEquipment protection level DbUL 22 ATEX 2869 X: . Equipment protection level Gb: UL 22 ATEX 2869 X. Equipment protection level Db: UL 22 ATEX 2869 X. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Measuring head temperature: -20 ... 125 °C (-4 ... 257 °F) directly at the mounting point. Storage temperature: -20 ... 60 °C (-4 ... 140 °F). Connection type: cable. Housing material: Stainless steel 1.4305 / AISI 303. Degree of protection: IP66 / IP67 only in connected state and correctly mounted housing cover. Cable: . Number of cores8LengthL2 m: . Number of cores: 8. Length: 2 m. Mass: 880 g. Dimensions: . Height46 mmWidth62 mmLength77.3 mm: . Height: 46 mm. Width: 62 mm. Length: 77.3 mm. Scope of delivery: 1 x allen head screw M8 x 20 1 x spring washer M8 1 x seal label. Use in the hazardous area: see instruction manuals Only use accessories specified by the manufacturer.
Specifications
General specifications
| Type | Vibration sensor |
| Measuring technology | MEMS |
| Series | Performance Plus Line |
| Measured variable | Vibration velocity |
| Measuring range | |
| Vibration velocityv-rms0 ... 32 mm/s | v-rms Vibration velocity |
| Vibration velocity | 0 ... 32 mm/s v-rms |
| Measurement accuracy | ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s |
| Cross-sensitivity | < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis |
| Frequency range | 10 ... 1000 Hz |
| Averaging time | for v-rms: 2 s |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| Performance level (PL) | PL d |
| Category | Cat. 2 |
| MTTFd | 329 a |
| Mission Time (TM) | 10 a |
| Diagnostic Coverage (DC) | min. 90 % |
Indicators/operating means
| Status indicator | 6 LEDs for operating states |
| Control elements | 4 rotary switches and 1 push button for programming |
Electrical specifications
| Fusing | external fuse is required: 3 A , semi-time-lag , 30 V DC |
| Operating voltage | 24 V DC + 7 % / - 10 % UB |
| Current consumption | max. 100 mA |
| Power consumption | 2.6 W P0 |
| Time delay before availability | 15 s (initially self-test functions are executed before safe measured values are available at the output) tv |
| Surge protection | up to 2 kV |
Output 1
| Output type | relay |
| Switching function | Normally open (NO) |
| Switching voltage | max. 30 V DC |
| Switching current | max. 1 A |
Output 2
| Output type | relay |
| Switching function | Normally open (NO) |
| Switching voltage | max. 30 V DC |
| Switching current | max. 1 A |
Output 3
| Output type | analog output, current output of the vibration variable |
| Output current | 4 ... 20 mA |
| Load resistor | ≤ 500 Ω |
Standard conformity
| Degree of protection | DIN EN 60529, IP66, IP67 |
| Shock resistance | DIN EN 60068-2-27, 60 g, 6 ms |
| Vibration resistance | DIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz |
| Vibration evaluation | DIN ISO 10816/20816 |
| Functional safety | DIN EN IEC 61508 , SIL 2 EN ISO 13849 , PL d |
Approvals and certificates
| IECEx approval | |
| Equipment protection level GbIECEx ULD 22.0031XEquipment protection level DbIECEx ULD 22.0031X | Equipment protection level Gb |
| Equipment protection level Gb | IECEx ULD 22.0031X |
| Equipment protection level Db | IECEx ULD 22.0031X |
| ATEX approval | |
| Equipment protection level GbUL 22 ATEX 2869 XEquipment protection level DbUL 22 ATEX 2869 X | Equipment protection level Gb |
| Equipment protection level Gb | UL 22 ATEX 2869 X |
| Equipment protection level Db | UL 22 ATEX 2869 X |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Measuring head temperature | -20 ... 125 °C (-4 ... 257 °F) directly at the mounting point |
| Storage temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Connection type | cable |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Degree of protection | IP66 / IP67 only in connected state and correctly mounted housing cover |
| Cable | |
| Number of cores8LengthL2 m | Number of cores |
| Number of cores | 8 |
| Length | 2 m L |
| Mass | 880 g |
| Dimensions | |
| Height46 mmWidth62 mmLength77.3 mm | Height |
| Height | 46 mm |
| Width | 62 mm |
| Length | 77.3 mm |
General information
| Scope of delivery | 1 x allen head screw M8 x 20 1 x spring washer M8 1 x seal label |
| Use in the hazardous area | see instruction manuals Only use accessories specified by the manufacturer. |