SIRIUS 3RT.3 contactors, 4-pole, up to 525 A Parts
























Compare SIRIUS 3RT.3 contactors, 4-pole, up to 525 A
Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.
| MPN | power loss [W] for rated value of the current — without load current share typical | Net Weight | control supply voltage at DC rated value | apparent pick-up power of magnet coil at AC — at 50 Hz | apparent holding power of magnet coil at AC — at 50 Hz |
|---|---|---|---|---|---|
| 3RT2348-1NP30 | 3.3 W | 2.03 kg | 175 ... 280 V | 151 V·A | 3.5 V·A |
| 3RT2348-1NF30 | 3.3 W | 2.036 kg | 83 ... 155 V | 151 V·A | 3.5 V·A |
| 3RT2336-1AV00 | 5.9 W | 1.1 kg | — | 190 V·A | 16 V·A |
| 3RT2336-1AU00 | 5.9 W | 1.096 kg | — | 190 V·A | 16 V·A |
| 3RT2336-1AP60 | 6.7 W | 1.106 kg | — | 212 V·A | 18.5 V·A |
| 3RT2326-2BF40 | 5.9 W | 715 g | 110 V | — | — |
| 3RT2326-2BB40 | 5.9 W | 716 g | 24 V | — | — |
| 3RT2326-2AP60 | 2.6 W | 543 g | — | 81 V·A | 10.5 V·A |
| 3RT2344-1NF30 | 3.3 W | 2.05 kg | 83 ... 155 V | 151 V·A | 3.5 V·A |
| 3RT2344-1NB30 | 3.3 W | 2.06 kg | 20 ... 33 V | 151 V·A | 3.5 V·A |
| 3RT2344-1AV00 | 7.2 W | 1.935 kg | — | 296 V·A | 19 V·A |
| 3RT2344-1AP60 | 8.8 W | 1.941 kg | — | 348 V·A | 25 V·A |
| 3RT2337-3NB30 | 2 W | 1.225 kg | 20 ... 33 V | 40 V·A | 2 V·A |
| 3RT2337-1NP30 | 2 W | 1.22 kg | 175 ... 280 V | 40 V·A | 2 V·A |
| 3RT2337-1NF30 | 2 W | 1.247 kg | 83 ... 155 V | 40 V·A | 2 V·A |
| 3RT1374-6AP36 | 4.5 W | 6.551 kg | 100 ... 250 V | 385 V·A | 17.5 V·A |
| 3RT1374-6AF36 | 2.5 W | 6.8 kg | 48 ... 130 V | 340 V·A | 17 V·A |
| 3RT1374-6AE36 | 3.5 W | 6.731 kg | 20 ... 60 V | 475 V·A | 8.5 V·A |
| 3RT1373-6AR36 | 4.7 W | 6.547 kg | 250 ... 500 V | 420 V·A | 21 V·A |
| 3RT1373-6AP36 | 4.5 W | 6.467 kg | 100 ... 250 V | 385 V·A | 17.5 V·A |
| 3RT1373-6AF36 | 2.5 W | 6.773 kg | 48 ... 130 V | 340 V·A | 17 V·A |
| 3RT2317-1BM40 | 4 W | 0.277 kg | 220 V | — | — |
| 3RT2317-1BG40 | 4 W | 0.272 kg | 125 V | — | — |
| 3RT2317-1BF40 | 4 W | 0.278 kg | 110 V | — | — |
Common to all listed parts
| product designation | Contactor |
| product extension — function module for communication | No |
| product extension — auxiliary switch | Yes |
| type of calculation of power loss current-dependent | quadratic |
| insulation voltage — of the auxiliary and control circuit with degree of pollution 3 rated value | 690 V |
| surge voltage resistance — of auxiliary circuit rated value | 6 kV |
| reference code according to IEC 81346-2 | Q |
| installation altitude at height above sea level maximum | 2 000 m |