Pepperl Fuchs RVI70E
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Incremental Rotary Encoders |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can RVI70E be shipped?
RVI70E is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up RVI70E in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for RVI70E and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for RVI70E, subject to availability and destination.
Incremental rotary encoder. Up to 5000 ppr, Flameproof enclosure, Worldwide certification: ATEX, IECEx, KOSHA, CCC, Degree of protection IP66 / IP67, High shaft load capacity, Enclosure type: 70 mm, Type of shaft: Solid shaft, Interface: push-pull, incremental or RS-422, incremental, Application: Ex protection, Detection type: photoelectric sampling, Output type: push-pull, incremental or RS 422, incremental <BR>(see "Output circuit" in the ordering information). Detection type: photoelectric sampling. Device type: Incremental rotary encoder. Pulse count: max. 5000. MTTFd: 140 a. L10: 1.6 E+9 at 3000 rpm. Operating voltage: 10 ... 30 V DC or 5 V DC ± 5 % (see "Output circuit" in the ordering information). No-load supply current: max. 60 mA. Output type: push-pull, incremental or RS 422, incremental (see "Output circuit" in the ordering information). Voltage drop: < 4 V (push-pull, incremental). Load current: max. per channel 35 mA , short-circuit protected, reverse polarity protected (push-pull, incremental) max. per channel 20 mA , short-circuit protected, reverse polarity protected (RS 422, incremental). Output frequency: max. 200 kHz. Rise time: 250 ns. Phase position A to B: 90 ° ± 18 °. Duty cycle: 1/2 ± 20 %. De-energized delay: 250 ns. Cable: ∅ 10.2 mm, Radox 9 x 0.5 mm2. Degree of protection: DIN EN 60529, IP66 DIN EN 60529, IP67. Climatic testing: DIN EN 60068-2-78 , no moisture condensation. Emitted interference: EN IEC 61000-6-4:2019. Noise immunity: EN IEC 61000-6-2:2019. Shock resistance: DIN EN 60068-2-27, 100 g, 3 ms. Vibration resistance: DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz. IECEx approval: . Equipment protection level GbIECEx ZLM 14.0003XEquipment protection level DbIECEx ZLM 14.0003X: . Equipment protection level Gb: IECEx ZLM 14.0003X. Equipment protection level Db: IECEx ZLM 14.0003X. ATEX approval: . Equipment protection level GbZELM 14 ATEX 0519 XEquipment protection level DbZELM 14 ATEX 0519 X: . Equipment protection level Gb: ZELM 14 ATEX 0519 X. Equipment protection level Db: ZELM 14 ATEX 0519 X. CCC approval: . Hazardous Location2020322314001105: . Hazardous Location: 2020322314001105. KCC approval: . Hazardous Location19-AV4BO-0390 and 19-AV4BO-0391: . Hazardous Location: 19-AV4BO-0390 and 19-AV4BO-0391. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Storage temperature: -40 ... 70 °C (-40 ... 158 °F). Material: . Combination 1housing: anodized aluminum flange: anodized aluminum shaft: Stainless steel 1.4401 / AISI 316Combination 2 (Inox)housing: Stainless steel 1.4401 / AISI 316 flange: Stainless steel 1.4401 / AISI 316 shaft: Stainless steel 1.4401 / AISI 316: . Combination 1: housing: anodized aluminum flange: anodized aluminum shaft: Stainless steel 1.4401 / AISI 316. Combination 2 (Inox): housing: Stainless steel 1.4401 / AISI 316 flange: Stainless steel 1.4401 / AISI 316 shaft: Stainless steel 1.4401 / AISI 316. Mass: approx. 1300 g (combination 1) approx. 2300 g (combination 2). Rotational speed: max. 6000 min -1. Moment of inertia: 400 gcm2. Starting torque: < 5 Ncm. Shaft load: . Axial110 NRadial150 N: . Axial: 110 N. Radial: 150 N. Use in the hazardous area: see instruction manuals
Specifications
General specifications
| Detection type | photoelectric sampling |
| Device type | Incremental rotary encoder |
| Pulse count | max. 5000 |
Functional safety related parameters
| MTTFd | 140 a |
| L10 | 1.6 E+9 at 3000 rpm |
Electrical specifications
| Operating voltage | 10 ... 30 V DC or 5 V DC ± 5 % (see "Output circuit" in the ordering information) UB |
| No-load supply current | max. 60 mA I0 |
Output
| Output type | push-pull, incremental or RS 422, incremental (see "Output circuit" in the ordering information) |
| Voltage drop | < 4 V (push-pull, incremental) Ud |
| Load current | max. per channel 35 mA , short-circuit protected, reverse polarity protected (push-pull, incremental) max. per channel 20 mA , short-circuit protected, reverse polarity protected (RS 422, incremental) |
| Output frequency | max. 200 kHz |
| Rise time | 250 ns |
| Phase position A to B | 90 ° ± 18 ° |
| Duty cycle | 1/2 ± 20 % |
| De-energized delay | 250 ns toff |
Connection
| Cable | ∅ 10.2 mm, Radox 9 x 0.5 mm2 |
Standard conformity
| Degree of protection | DIN EN 60529, IP66 DIN EN 60529, IP67 |
| Climatic testing | DIN EN 60068-2-78 , no moisture condensation |
| Emitted interference | EN IEC 61000-6-4:2019 |
| Noise immunity | EN IEC 61000-6-2:2019 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz |
Approvals and certificates
| IECEx approval | |
| Equipment protection level GbIECEx ZLM 14.0003XEquipment protection level DbIECEx ZLM 14.0003X | Equipment protection level Gb |
| Equipment protection level Gb | IECEx ZLM 14.0003X |
| Equipment protection level Db | IECEx ZLM 14.0003X |
| ATEX approval | |
| Equipment protection level GbZELM 14 ATEX 0519 XEquipment protection level DbZELM 14 ATEX 0519 X | Equipment protection level Gb |
| Equipment protection level Gb | ZELM 14 ATEX 0519 X |
| Equipment protection level Db | ZELM 14 ATEX 0519 X |
| CCC approval | |
| Hazardous Location2020322314001105 | Hazardous Location |
| Hazardous Location | 2020322314001105 |
| KCC approval | |
| Hazardous Location19-AV4BO-0390 and 19-AV4BO-0391 | Hazardous Location |
| Hazardous Location | 19-AV4BO-0390 and 19-AV4BO-0391 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Material | |
| Combination 1housing: anodized aluminum flange: anodized aluminum shaft: Stainless steel 1.4401 / AISI 316Combination 2 (Inox)housing: Stainless steel 1.4401 / AISI 316 flange: Stainless steel 1.4401 / AISI 316 shaft: Stainless steel 1.4401 / AISI 316 | Combination 1 |
| Combination 1 | housing: anodized aluminum flange: anodized aluminum shaft: Stainless steel 1.4401 / AISI 316 |
| Combination 2 (Inox) | housing: Stainless steel 1.4401 / AISI 316 flange: Stainless steel 1.4401 / AISI 316 shaft: Stainless steel 1.4401 / AISI 316 |
| Mass | approx. 1300 g (combination 1) approx. 2300 g (combination 2) |
| Rotational speed | max. 6000 min -1 |
| Moment of inertia | 400 gcm2 |
| Starting torque | < 5 Ncm |
| Shaft load | |
| Axial110 NRadial150 N | Axial |
| Axial | 110 N |
| Radial | 150 N |
General information
| Use in the hazardous area | see instruction manuals |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G


