Pepperl Fuchs KC-LCDC-48-2R-24VDC
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Pulse Counter Units and Displays |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KC-LCDC-48-2R-24VDC be shipped?
KC-LCDC-48-2R-24VDC is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KC-LCDC-48-2R-24VDC in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KC-LCDC-48-2R-24VDC and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KC-LCDC-48-2R-24VDC, subject to availability and destination.
Timer, Counter, Tachometer. Counter/Timer/Tachometer, Adding/subtracting via 2 separate inputs, Batch controller with 2 pre-selections, Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs, Multicolor display, Operating voltage: 10 ... 30 V DC, Relay: changeover contact , Make contact, Output I: Relay with make contact, NC or NO progr., Output II: Relay with changeover contact, Dimensions: 48 mm x 48 mm x 109.8 mm. Pre-selection: 2-fold. Data storage: > 10 years, EEPROM. Programming: keypad-driven menu. Type: 2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit. Display value: digit height 9 mm. Pre-selection: digit height 7 mm. Key interlock: via "high" potential at "LOCK" input. Decimal point: 0 to max 5 fractional digits. Scale factor: 0.0001 ... 99.9999. Reset: manually or external. Fusing: 10 … 30 V DC: T 0.2 A. Operating voltage: 10 ... 30 V DC. Power consumption: max. 1.5 W. Connection: Counter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI. Signal voltage: . High0.6 x Ue ... 30 V DCLow0 ... 0.2 x Ue: . High: 0.6 x Ue ... 30 V DC. Low: 0 ... 0.2 x Ue. Counting frequency: 30 Hz / 55 kHz. Minimum pulse duration: Control/reset inputs: 10 ms / 1 ms. Impedance: 5 kOhm. Count modes: . Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100% Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 %TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto): . Pulse counter: Counting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100%. Frequency counter: functions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 %. Timer: Time measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto). Relay: changeover contact , Make contact. Switching voltagemax. 250 V AC / 110 V DCSwitching currentmax. 3 A AC/DC, min. 30 mA DC,Switching powermax. 750 VA / 90 W: . Switching voltage: max. 250 V AC / 110 V DC. Switching current: max. 3 A AC/DC, min. 30 mA DC,. Switching power: max. 750 VA / 90 W. Sensor supply: connected power supply is looped through,max. 80 mA. Output I: Relay with make contact, NC or NO progr.. Mechanical life2 x 107 switching cyclesElectrical life1 x 105 switching cycles at 3 A: . Mechanical life: 2 x 107 switching cycles. Electrical life: 1 x 105 switching cycles at 3 A. Output II: Relay with changeover contact. Mechanical life2 x 107 switching cyclesElectrical life5 x 104 cycles at 3 A: . Mechanical life: 2 x 107 switching cycles. Electrical life: 5 x 104 cycles at 3 A. Response time: Relay: approx. 7 ms Frequency counter: 100/600 ms. Directive conformity: . EMC Directive 2004/108/ECEN 61000-6-2:2005: . EMC Directive 2004/108/EC: EN 61000-6-2:2005. Standard conformity: . Emitted interferenceDIN EN 55011:2009, Class BMech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each directionShock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction: . Emitted interference: DIN EN 55011:2009, Class B. Mech. capacity: EN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction. Shock and impact resistance: EN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction. Ambient temperature: -20 ... 65 °C (-4 ... 149 °F). Storage temperature: -25 ... 75 °C (-13 ... 167 °F). Relative humidity: ≤ 93 % at 40 °C (noncondensing). Altitude: 0 ... 2000 m. Degree of protection: IP65 (front). Mass: approx. 138 g. Dimensions: 48 mm x 48 mm x 109.8 mm
Specifications
General specifications
| Pre-selection | 2-fold |
| Data storage | > 10 years, EEPROM |
| Programming | keypad-driven menu |
Indicators/operating means
| Type | 2-line, 2 x 6-digit LC display with leading sign Multicolor, backlit |
| Display value | digit height 9 mm |
| Pre-selection | digit height 7 mm |
| Key interlock | via "high" potential at "LOCK" input |
| Decimal point | 0 to max 5 fractional digits |
| Scale factor | 0.0001 ... 99.9999 |
| Reset | manually or external |
Electrical specifications
| Fusing | 10 … 30 V DC: T 0.2 A |
| Operating voltage | 10 ... 30 V DC UB |
| Power consumption | max. 1.5 W P0 |
Input
| Connection | Counter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI |
| Signal voltage | |
| High0.6 x Ue ... 30 V DCLow0 ... 0.2 x Ue | High |
| High | 0.6 x Ue ... 30 V DC |
| Low | 0 ... 0.2 x Ue |
| Counting frequency | 30 Hz / 55 kHz |
| Minimum pulse duration | Control/reset inputs: 10 ms / 1 ms |
| Impedance | 5 kOhm |
| Count modes | |
| Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100% Frequency counterfunctions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 %TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) | Pulse counter |
| Pulse counter | Counting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad), Cumulative counting (up.up),up/down counting x 2 (quad 2),up/down counting x 4 (quad 4),additional functions for counter input A and counter input B: A/B, (A-B)/A x 100% |
| Frequency counter | functions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % |
| Timer | Time measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) |
Output
| Relay | changeover contact , Make contact |
| Switching voltagemax. 250 V AC / 110 V DCSwitching currentmax. 3 A AC/DC, min. 30 mA DC,Switching powermax. 750 VA / 90 W | Switching voltage |
| Switching voltage | max. 250 V AC / 110 V DC |
| Switching current | max. 3 A AC/DC, min. 30 mA DC, |
| Switching power | max. 750 VA / 90 W |
| Sensor supply | connected power supply is looped through,max. 80 mA |
| Output I | Relay with make contact, NC or NO progr. |
| Mechanical life2 x 107 switching cyclesElectrical life1 x 105 switching cycles at 3 A | Mechanical life |
| Mechanical life | 2 x 107 switching cycles |
| Electrical life | 1 x 105 switching cycles at 3 A |
| Output II | Relay with changeover contact |
| Mechanical life2 x 107 switching cyclesElectrical life5 x 104 cycles at 3 A | Mechanical life |
| Mechanical life | 2 x 107 switching cycles |
| Electrical life | 5 x 104 cycles at 3 A |
| Response time | Relay: approx. 7 ms Frequency counter: 100/600 ms |
Compliance with standards and directives
| Directive conformity | |
| EMC Directive 2004/108/ECEN 61000-6-2:2005 | EMC Directive 2004/108/EC |
| EMC Directive 2004/108/EC | EN 61000-6-2:2005 |
| Standard conformity | |
| Emitted interferenceDIN EN 55011:2009, Class BMech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each directionShock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction | Emitted interference |
| Emitted interference | DIN EN 55011:2009, Class B |
| Mech. capacity | EN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction |
| Shock and impact resistance | EN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction |
Ambient conditions
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) |
| Storage temperature | -25 ... 75 °C (-13 ... 167 °F) |
| Relative humidity | ≤ 93 % at 40 °C (noncondensing) |
| Altitude | 0 ... 2000 m |
Mechanical specifications
| Degree of protection | IP65 (front) |
| Mass | approx. 138 g |
| Dimensions | 48 mm x 48 mm x 109.8 mm |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G