Available on request

Pepperl Fuchs KC-LCD-48-1R-230VAC

MPN: KC-LCD-48-1R-230VAC · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryPulse Counter Units and Displays
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can KC-LCD-48-1R-230VAC be shipped?

KC-LCD-48-1R-230VAC is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KC-LCD-48-1R-230VAC in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KC-LCD-48-1R-230VAC and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KC-LCD-48-1R-230VAC, subject to availability and destination.

Timer, Counter. Counter/Timer, Adding/subtracting via 2 separate inputs, Batch controller with 1 pre-selection, Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and output status, Display range and preselection range from -999999 up to 999999

Overflow will be evaluated correctly up to 1 decade, Operating voltage: 230 V AC , Relay: changeover contact, Dimensions: 48 mm x 48 mm x 109.8 mm. Pre-selection: single. Data storage: > 10 years, EEPROM. Programming: keypad-driven menu. Type: 2-line, 2 x 6-digit LC display with leading sign. Display value: digit height 9 mm. Pre-selection: digit height 7 mm. Key interlock: via "high" potential at "LOCK" input. Decimal point: 0 to max 5 fractional digits. Scale factor: 0.0001 ... 99.9999. Reset: manually or external. Fusing: T 0.1 A. Operating voltage: 230 V AC. Power consumption: max. 6.5 VA. Connection: Counter inputs: A and B Control/reset inputs: LOCK, RESET. Signal voltage: . High3.5 ... 30 V DCLow0 ... 2 V DC: . High: 3.5 ... 30 V DC. Low: 0 ... 2 V DC. Counting frequency: 30 Hz / 5 kHz. Minimum pulse duration: Control/reset inputs: static / 1 ms. Impedance: 10 kOhm. Count modes: . Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad),TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.),: . Pulse counter: Counting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad),. Timer: Time measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.),. Relay: changeover contact. Switching voltagemax. 250 V AC / 110 V DCSwitching currentmax. 3 A AC/DC, min. 30 mA DC,Switching powermax. 750 VA / 90 WMechanical life2 x 107 switching cyclesElectrical life5 x 104 cycles at 3 AResponse time< 15 ms pulse counter < 10 ms time counter: . Switching voltage: max. 250 V AC / 110 V DC. Switching current: max. 3 A AC/DC, min. 30 mA DC,. Switching power: max. 750 VA / 90 W. Mechanical life: 2 x 107 switching cycles. Electrical life: 5 x 104 cycles at 3 A. Response time: < 15 ms pulse counter < 10 ms time counter. Sensor supply: 14.4 ... 27.6 V DC max. 50 mA at 230 VAC. Directive conformity: . Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999: . Low Voltage Directive 2006/95/EC: EN 61010-1:2001; protection class: 2. EMC Directive 2004/108/EC: EN 61000-6-2:2005, EN 50295:1999. Standard conformity: . Emitted interferenceDIN EN 55011:2009, Class BMech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each directionShock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction: . Emitted interference: DIN EN 55011:2009, Class B. Mech. capacity: EN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction. Shock and impact resistance: EN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction. Ambient temperature: -10 ... 50 °C (14 ... 122 °F). Storage temperature: -25 ... 75 °C (-13 ... 167 °F). Relative humidity: ≤ 93 % at 40 °C(noncondensing). Altitude: 0 ... 2000 m. Pollution degree: 2. Degree of protection: IP65 (front). Mass: approx. 230 g. Dimensions: 48 mm x 48 mm x 109.8 mm

Specifications

General specifications

Pre-selectionsingle
Data storage> 10 years, EEPROM
Programmingkeypad-driven menu

Indicators/operating means

Type2-line, 2 x 6-digit LC display with leading sign
Display valuedigit height 9 mm
Pre-selectiondigit height 7 mm
Key interlockvia "high" potential at "LOCK" input
Decimal point0 to max 5 fractional digits
Scale factor0.0001 ... 99.9999
Resetmanually or external

Electrical specifications

FusingT 0.1 A
Operating voltage230 V AC UB
Power consumptionmax. 6.5 VA P0

Input

ConnectionCounter inputs: A and B Control/reset inputs: LOCK, RESET
Signal voltage
High3.5 ... 30 V DCLow0 ... 2 V DC High
High3.5 ... 30 V DC
Low0 ... 2 V DC
Counting frequency30 Hz / 5 kHz
Minimum pulse durationControl/reset inputs: static / 1 ms
Impedance10 kOhm
Count modes
Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad),TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.), Pulse counter
Pulse counterCounting with counting direction (cnt.dir),difference counting (up.dn),up/down counting (quad),
TimerTime measurement via GATE input (FrErun),counter input A: Start, counter input B: Stop (InpA.InpB.),counter input B: Start/Stop (InpB.InpB.),

Output

Relaychangeover contact
Switching voltagemax. 250 V AC / 110 V DCSwitching currentmax. 3 A AC/DC, min. 30 mA DC,Switching powermax. 750 VA / 90 WMechanical life2 x 107 switching cyclesElectrical life5 x 104 cycles at 3 AResponse time< 15 ms pulse counter < 10 ms time counter Switching voltage
Switching voltagemax. 250 V AC / 110 V DC
Switching currentmax. 3 A AC/DC, min. 30 mA DC,
Switching powermax. 750 VA / 90 W
Mechanical life2 x 107 switching cycles
Electrical life5 x 104 cycles at 3 A
Response time< 15 ms pulse counter < 10 ms time counter
Sensor supply14.4 ... 27.6 V DC max. 50 mA at 230 VAC

Compliance with standards and directives

Directive conformity
Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999 Low Voltage Directive 2006/95/EC
Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2
EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999
Standard conformity
Emitted interferenceDIN EN 55011:2009, Class BMech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each directionShock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction Emitted interference
Emitted interferenceDIN EN 55011:2009, Class B
Mech. capacityEN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction
Shock and impact resistanceEN 60068-2-27:1995 100 G / 2 ms / XYZ3 times in each direction

Ambient conditions

Ambient temperature-10 ... 50 °C (14 ... 122 °F)
Storage temperature-25 ... 75 °C (-13 ... 167 °F)
Relative humidity≤ 93 % at 40 °C(noncondensing)
Altitude0 ... 2000 m
Pollution degree2

Mechanical specifications

Degree of protectionIP65 (front)
Massapprox. 230 g
Dimensions48 mm x 48 mm x 109.8 mm
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl Fuchs KC-CTT-3GN2BUAvailable on requestPepperl Fuchs KC-CTT-3GN2BU
MPN: KC-CTT-3GN2BU · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs KC-CTT-5BUAvailable on requestPepperl Fuchs KC-CTT-5BU
MPN: KC-CTT-5BU · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs KC-CTT-5GNAvailable on requestPepperl Fuchs KC-CTT-5GN
MPN: KC-CTT-5GN · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs KC-LCD-24-24VDCAvailable on requestPepperl Fuchs KC-LCD-24-24VDC
MPN: KC-LCD-24-24VDC · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs KC-LCD-48-1R-24VDCAvailable on requestPepperl Fuchs KC-LCD-48-1R-24VDC
MPN: KC-LCD-48-1R-24VDC · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs KC-LCDC-48-2R-230VACAvailable on requestPepperl Fuchs KC-LCDC-48-2R-230VAC
MPN: KC-LCDC-48-2R-230VAC · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs KC-LCDC-48-2R-24VDCAvailable on requestPepperl Fuchs KC-LCDC-48-2R-24VDC
MPN: KC-LCDC-48-2R-24VDC · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs KC-LCDC-48-2T-230VACAvailable on requestPepperl Fuchs KC-LCDC-48-2T-230VAC
MPN: KC-LCDC-48-2T-230VAC · Pepperl Fuchs
Price on request
Request a quote