Pepperl Fuchs FB6215BR
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | FB (Zone 1) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FB6215BR be shipped?
FB6215BR is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FB6215BR in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FB6215BR and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FB6215BR, subject to availability and destination.
Digital Output. 4-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Solenoid Valve, Field device [2]: audible alarm, Field device [3]: visual alarm. Occupied slots: 2. Connection: backplane bus / 24 V booster via wire ends. Rated voltage: 12 V DC , only in connection with the power supplies FB92**. Input voltage range: 18.5 ... 32 V DC (SELV/PELV) booster voltage. Power dissipation: 3 W. Power consumption: 0.15 W. Connection: backplane bus. Interface: manufacturer-specific bus to standard com unit. Number of channels: 4. Suitable field devices: . Field deviceSolenoid ValveField device [2]audible alarmField device [3]visual alarm: . Field device: Solenoid Valve. Field device [2]: audible alarm. Field device [3]: visual alarm. Connection: channel I: 9+, 10-; channel II: 11+, 12-; channel III: 13+, 14-; channel IV: 15+, 16-. Internal resistor: max. 90 Ω. Current limit: 70 mA. Open loop voltage: 16.6 V. Line fault detection: can be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms). Short-circuit< 100 ΩOpen-circuit> 15 kΩ: . Short-circuit: < 100 Ω. Open-circuit: > 15 kΩ. Response time: 10 ms (depending on bus cycle time). Watchdog: within 0.5 s the device goes in safe state, e.g. after loss of communication. Reaction time: 10 s. LED indication: LED green: supply LED red: line fault , red flashing: communication error. Coding: optional mechanical coding via front socket. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1: . Directive 2014/30/EU: EN 61326-1. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Environmental test: EN 60068-2-14. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Damaging gas: EN 60068-2-42. Relative humidity: EN 60068-2-78. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 95 % non-condensing. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , a separate housing is required acc. to the system description. Connection: removable front connector with screw flange (accessory)wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2). Mass: approx. 750 g. Dimensions: 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch). EU-type examination certificate: PTB 97 ATEX 1074 U. Marking II 2(1) G Ex d [ia Ga] IIC Gb [exsign] II (1) D [Ex ia Da] IIIC: . Marking: II 2(1) G Ex d [ia Ga] IIC Gb [exsign] II (1) D [Ex ia Da] IIIC. Output: . VoltageUo18.9 VCurrentIo286 mAPowerPo1351 mWInternal capacitanceCi2.5 nFInternal inductanceLi0 mH: Uo. Voltage: 18.9 V. Current: 286 mA. Power: 1351 mW. Internal capacitance: 2.5 nF. Internal inductance: 0 mH. Galvanic isolation: . Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V: . Output/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006: . Directive 2014/34/EU: EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006. ATEX approval: PTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U. EAC approval: Russia: RU C-IT.MIII06.B.00129. Marine approval: . Lloyd Register15/20021DNV GL MarineTAA0000034American Bureau of ShippingT1450280/UNBureau Veritas Marine22449/B0 BV: . Lloyd Register: 15/20021. DNV GL Marine: TAA0000034. American Bureau of Shipping: T1450280/UN. Bureau Veritas Marine: 22449/B0 BV. System information: The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
Slots
| Occupied slots | 2 |
Supply
| Connection | backplane bus / 24 V booster via wire ends |
| Rated voltage | 12 V DC , only in connection with the power supplies FB92** |
| Input voltage range | 18.5 ... 32 V DC (SELV/PELV) booster voltage |
| Power dissipation | 3 W |
| Power consumption | 0.15 W |
Internal bus
| Connection | backplane bus |
| Interface | manufacturer-specific bus to standard com unit |
Digital output
| Number of channels | 4 |
| Suitable field devices | |
| Field deviceSolenoid ValveField device [2]audible alarmField device [3]visual alarm | |
| Field device | Solenoid Valve |
| Field device [2] | audible alarm |
| Field device [3] | visual alarm |
| Connection | channel I: 9+, 10-; channel II: 11+, 12-; channel III: 13+, 14-; channel IV: 15+, 16- |
| Internal resistor | max. 90 Ω |
| Current limit | 70 mA |
| Open loop voltage | 16.6 V |
| Line fault detection | can be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms) |
| Short-circuit< 100 ΩOpen-circuit> 15 kΩ | |
| Short-circuit | < 100 Ω |
| Open-circuit | > 15 kΩ |
| Response time | 10 ms (depending on bus cycle time) |
| Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication |
| Reaction time | 10 s |
Indicators/settings
| LED indication | LED green: supply LED red: line fault , red flashing: communication error |
| Coding | optional mechanical coding via front socket |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1 | |
| Directive 2014/30/EU | EN 61326-1 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Environmental test | EN 60068-2-14 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Damaging gas | EN 60068-2-42 |
| Relative humidity | EN 60068-2-78 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
| Connection | removable front connector with screw flange (accessory)wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) |
| Mass | approx. 750 g |
| Dimensions | 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) |
Data for application in connection with hazardous areas
| EU-type examination certificate | PTB 97 ATEX 1074 U |
| Marking II 2(1) G Ex d [ia Ga] IIC Gb [exsign] II (1) D [Ex ia Da] IIIC | |
| Marking | II 2(1) G Ex d [ia Ga] IIC Gb [exsign] II (1) D [Ex ia Da] IIIC |
| Output | |
| VoltageUo18.9 VCurrentIo286 mAPowerPo1351 mWInternal capacitanceCi2.5 nFInternal inductanceLi0 mH | Uo |
| Voltage | 18.9 V |
| Current | 286 mA |
| Power | 1351 mW |
| Internal capacitance | 2.5 nF |
| Internal inductance | 0 mH |
| Galvanic isolation | |
| Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V | |
| Output/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006 | |
| Directive 2014/34/EU | EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006 |
International approvals
| ATEX approval | PTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U |
| EAC approval | Russia: RU C-IT.MIII06.B.00129 |
| Marine approval | |
| Lloyd Register15/20021DNV GL MarineTAA0000034American Bureau of ShippingT1450280/UNBureau Veritas Marine22449/B0 BV | |
| Lloyd Register | 15/20021 |
| DNV GL Marine | TAA0000034 |
| American Bureau of Shipping | T1450280/UN |
| Bureau Veritas Marine | 22449/B0 BV |
General information
| System information | The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |