IFM SU9004
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Ultrasonic flow meters |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SU9004 be shipped?
SU9004 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SU9004 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SU9004 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SU9004, subject to availability and destination.
Reliable detection of flow and medium temperature Suitable for water, oils and glycol solutions For installation in pipes With two scalable analogue outputs Clearly visible 4-digit LED display
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 2 |
| Measuring range | 0...200 l/min; 0...52.84 gpm |
| 0...200 l/min | 0...52.84 gpm |
| Process connection | threaded connection G 1 1/4 external thread flat seal |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | water; glycol solutions; coolants; oils |
| Note on media | low-viscosity oils with viscosity: 7...40 mm²/s (40 °C); high-viscosity oils with viscosity: 30...68 mm²/s (40 °C) |
| Medium temperature[°C] [°C] | -10...80 |
| Pressure rating | 16 bar; 1.6 MPa |
| 16 bar | 1.6 MPa |
Electrical data
| Operating voltage[V] [V] | 19...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | 100 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 10 |
| Measuring principle | ultrasonic |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Output signal | analogue signal |
| Number of analogue outputs | 2 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...200 l/min; 0...52.84 gpm |
| 0...200 l/min | 0...52.84 gpm |
| Display range | 0...240 l/min; 0...63.42 gpm |
| 0...240 l/min | 0...63.42 gpm |
| Resolution | 0.1 l/min; 0.02 gpm |
| 0.1 l/min | 0.02 gpm |
| Analogue start point ASP | 0...160 l/min; 0...42.28 gpm |
| 0...160 l/min | 0...42.28 gpm |
| Analogue end point AEP | 40...200 l/min; 10.28...52.84 gpm |
| 40...200 l/min | 10.28...52.84 gpm |
| Max. flow rate[l/min] [l/min] | 220 |
| In steps of | 0.1 l/min; 0.02 gpm |
| Measuring range[°C] [°C] | -10...80 |
| Resolution[°C] [°C] | 0.2 |
| Analogue start point[°C] [°C] | -10...62 |
| Analogue end point[°C] [°C] | 8...80 |
| In steps of[°C] [°C] | 0.2 |
Accuracy / deviations
| Accuracy (in the measuring range) | water: < ± (3 % MW + 0,2 % MEW); glycol (35 %), oil (viscosity 68 mm²/s at 40 °C): < ± (8 % MW + 0,5 % MEW) |
| Repeatability | 1 l/min; 60 l/h; 0,05 gpm; 3 gph |
| Accuracy[K] [K] | ± 3 (Q > 20 l/min) |
Response times
| Response time[s] [s] | 0.25; (dAP = 0) |
| Damping process value dAP[s] [s] | 0...1 |
| Dynamic response T05 / T09[s] [s] | T09 = 30 (Q > 20 l/min); (water) |
Operating conditions
| Ambient temperature[°C] [°C] | -10...60 |
| Storage temperature[°C] [°C] | -25...80 |
| Protection | IP 67 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5 kV |
| EN 61000-4-6 HF conducted | 10 V |
| CPA approval | model number; 001US; accuracy class; 3; maximum allowable error; -; Q (min); 0,3 m³/h; Q (t); 0,84 m³/h; Q (max); 12 m³/h |
| model number | 001US |
| accuracy class | 3 |
| maximum allowable error | - |
| Q (min) | 0,3 m³/h |
| Q (t) | 0,84 m³/h |
| Q (max) | 12 m³/h |
| Shock resistance | DIN IEC 68-2-27; 20 g (11 ms) |
| DIN IEC 68-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 5 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 203 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 1883 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 130 x 100 x 80.5 |
| Materials | housing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA |
| Materials (wetted parts) | Pipe section: stainless steel (316L/1.4404); Process connection sealing: NBR reinforced fibre Flat seal; FKM; PPS |
| Process connection | threaded connection G 1 1/4 external thread flat seal |
Displays / operating elements
| Display | Display unit; 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F); measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit |
| Display unit | l/min; m³/h; gpm; gph; °C; °F |
| measured values | alphanumeric display, 4-digit |
| programming | alphanumeric display, 4-digit |
Accessories
| Items supplied | sealings: 2, Centellen |
| Accessories (optional) | adapter for pipe: 1 x R 1, stainless steel, E40205; adapter for pipe: 1 x 1" NPT, stainless steel, E40206 |
Remarks
| Remarks | sealing: only with supplied Centellen seals; MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |