Quick facts
| Availability | Confirmed on request |
| Category | Ultrasonic flow meters |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SU9001 be shipped?
SU9001 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SU9001 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SU9001 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SU9001, subject to availability and destination.
Precise measurement of flow, consumption and medium temperature Suitable for water, oils and glycol solutions For installation in pipes With switching output, analogue output and pulse output Clearly visible 4-digit LED display
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range | 0...3170 gph; 0...52.84 gpm |
| 0...3170 gph | 0...52.84 gpm |
| Process connection | threaded connection G 1 1/4 external thread flat seal |
Application
| Special feature | Gold-plated contacts |
| Application | totaliser function; for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | water; glycol solutions; coolants; oils |
| Note on media | low-viscosity oils with viscosity: 7...40 mm²/s (40 °C); high-viscosity oils with viscosity: 30...68 mm²/s (40 °C) |
| Medium temperature[°F] [°F] | 14...176 |
| Pressure rating | 16 bar; 232 psi; 1.6 MPa |
| 16 bar | 232 psi |
Electrical data
| Operating voltage[V] [V] | 19...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | 100 |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 10 |
| Measuring principle | ultrasonic |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs
| Inputs | counter reset |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; pulse signal; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250; (per output) |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Analogue voltage output[V] [V] | 0...10; (scalable) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0...3170 gph; 0...52.84 gpm |
| 0...3170 gph | 0...52.84 gpm |
| Display range | 0...3804 gph; 0...63.4 gpm |
| 0...3804 gph | 0...63.4 gpm |
| Resolution | 1 gph; 0.02 gpm |
| 1 gph | 0.02 gpm |
| Set point SP | 7...3170 gph; 0.12...52.84 gpm |
| 7...3170 gph | 0.12...52.84 gpm |
| Reset point rP | 0...3163 gph; 0...52.72 gpm |
| 0...3163 gph | 0...52.72 gpm |
| Analogue start point ASP | 0...2547 gph; 0...42.46 gpm |
| 0...2547 gph | 0...42.46 gpm |
| Analogue end point AEP | 621...3170 gph; 10.36...52.84 gpm |
| 621...3170 gph | 10.36...52.84 gpm |
| Max. flow rate | 3804 gph; 63.4 gpm |
| 3804 gph | 63.4 gpm |
| In steps of | 0.02 gal |
| Pulse value | 0.02...9000 * 10³ gal |
| Pulse length[s] [s] | 0,095...2 |
| Measuring range[°F] [°F] | 14...176 |
| Resolution[°F] [°F] | 0.5 |
| Set point SP[°F] [°F] | 14.5...176 |
| Reset point rP[°F] [°F] | 14...175.5 |
| Analogue start point[°F] [°F] | 14...144 |
| Analogue end point[°F] [°F] | 46...176 |
| In steps of[°F] [°F] | 0.5 |
Accuracy / deviations
| Accuracy (in the measuring range) | water: < ± (3 % MW + 0,2 % MEW); glycol (35 %), oil (viscosity 68 mm²/s at 40 °C): < ± (8 % MW + 0,5 % MEW) |
| Repeatability | 0,05 gpm; 3 gph |
| Accuracy[K] [K] | ± 5,4 (Q > 0,26 gpm) |
Response times
| Response time[s] [s] | 0.25; (dAP = 0) |
| Delay time programmable dS, dr[s] [s] | 0...50 |
| Damping process value dAP[s] [s] | 0...1 |
| Dynamic response T05 / T09[s] [s] | T09 = 30 (Q > 5 gpm); (water) |
Software / programming
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring |
Operating conditions
| Ambient temperature[°F] [°F] | 14...140 |
| Storage temperature[°F] [°F] | -13...176 |
| Protection | IP 67 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-5 Surge; 0,5 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN IEC 68-2-27; 20 g (11 ms) |
| DIN IEC 68-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 5 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 185 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 1859 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 130 x 100 x 80.5 |
| Materials | housing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA |
| Materials (wetted parts) | Pipe section: stainless steel (316L/1.4404); Process connection sealing: NBR reinforced fibre Flat seal; FKM; PPS |
| Process connection | threaded connection G 1 1/4 external thread flat seal |
Displays / operating elements
| Display | Display unit; 5 x LED, green (gpm, gph, gal, °F, 10³); switching status; 2 x LED, yellow; measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit |
| Display unit | 5 x LED, green (gpm, gph, gal, °F, 10³) |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, 4-digit |
| programming | alphanumeric display, 4-digit |
Accessories
| Items supplied | sealings: 2, Centellen |
| Accessories (optional) | adapter for pipe: 1 x 1" NPT, stainless steel, E40206 |
Remarks
| Remarks | sealing: only with supplied Centellen seals; MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Moulded body: brass, Optalloy-plated; Contacts: gold-plated |