Available on request

IFM SU8631

MPN: SU8631 · Brand: IFM
Price on request
12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryUltrasonic flow meters
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can SU8631 be shipped?

SU8631 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SU8631 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SU8631 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SU8631, subject to availability and destination.

Accurate flow measurement of ultrapure water, water, oils and glycol solutions A robust, component-free measuring pipe made of stainless steel offers high media resistance and permanent ingress resistance The highly accurate inline measurement process eliminates any influence of varying wall thicknesses and pipe materials Operating status LED signals the sensor status and allows conclusions about process quality Convenient operation via buttons or parameter setting via IO-Link

Specifications

Product characteristics

Measuring range1...240 l/min; 0.06...14.4 m³/h; 16...3804 gph; 0.26...63.4 gpm
1...240 l/min0.06...14.4 m³/h
Process connectionthreaded connection 1" NPT external thread DN25

Application

Special featureGold-plated contacts
Mediaultra-pure water; water; hydrous media; glycol solutions; oils; coolants
Note on mediahydrous media: for media with >10 % additives, the repeatability is the only available value; low-viscosity oils with viscosity: 7...40 mm²/s (40 °C); high-viscosity oils with viscosity: 30...68 mm²/s (40 °C)
Medium temperature-20...100 °C; -4...212 °F
-20...100 °C-4...212 °F
Min. burst pressure150 bar; 15 MPa
150 bar15 MPa
Pressure rating100 bar; 10 MPa
100 bar10 MPa
Vacuum resistance[mbar] [mbar]-1000

Electrical data

Operating voltage[V] [V]18...32 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 75
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]5
Measuring principleultrasonic

Inputs

Inputscounter reset

Outputs

Total number of outputs2
Output signalswitching signal; pulse signal; analogue signal; IO-Link; frequency signal; diagnostic signal; totaliser switching signal
Electrical designPNP/NPN
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]0...10000
Analogue current output[mA] [mA]4...20
Max. load[Ω] [Ω]500
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-20...100 °C; -4...212 °F
1...240 l/min0.06...14.4 m³/h
Display range-44...124 °C; -47.2...255.2 °F
-288...288 l/min-17.28...17.28 m³/h
Resolution0.1 °C; 0.1 °F
0.1 l/min0.001 m³/h
Set point SP-19.6...100 °C; -3.2...212 °F
2.3...240 l/min0.139...14.4 m³/h
Reset point rP-20...99.6 °C; -4...211.2 °F
1.1...238.8 l/min0.064...14.325 m³/h
Analogue start point ASP-240...192 l/min; -14.4...11.522 m³/h; -3804...3044 gph; -63.4...50.73 gpm
-240...192 l/min-14.4...11.522 m³/h
Analogue end point AEP-191.9...240 l/min; -11.511...14.4 m³/h; -3041...3804 gph; -50.68...63.4 gpm
-191.9...240 l/min-11.511...14.4 m³/h
Low flow cut-off LFC1...12 l/min; 0.06...0.72 m³/h; 16...190 gph; 0.26...3.17 gpm
1...12 l/min0.06...0.72 m³/h
Frequency end point, FEP4...100 °C; 4...212 °F
48.1...240 l/min2.889...14.4 m³/h
Frequency at the end point FRP[Hz] [Hz]1...10000
Pulse length[s] [s]0.002...2
Pulse value0.02...99990000 l; 0.005...26414563.515 gal
-20...100 °C-4...212 °F
-44...124 °C-47.2...255.2 °F
0.1 °C0.1 °F
-19.6...100 °C-3.2...212 °F
-20...99.6 °C-4...211.2 °F
Analogue start point-20...76 °C; -4...168.8 °F
-20...76 °C4...168.8 °F
Analogue end point4...100 °C; 39.2...212 °F
4...100 °C4...212 °F
Frequency start point, FSP-20...76 °C; 4...168.8 °F

Accuracy / deviations

Accuracy (in the measuring range)glycol solutions (35%); ±(5,0 % MW + 0,5 % MEW); high-viscosity oils with viscosity 46mm2/s (40°C); ±(5,0 % MW + 0,5 % MEW); low-viscosity oils with viscosity 10mm2/s (40°C); ±(5,0 % MW + 0,5 % MEW); water; ± (1,0 % MW + 0,5 % MEW)
glycol solutions (35%)±(5,0 % MW + 0,5 % MEW)
high-viscosity oils with viscosity 46mm2/s (40°C)±(5,0 % MW + 0,5 % MEW)
low-viscosity oils with viscosity 10mm2/s (40°C)±(5,0 % MW + 0,5 % MEW)
water± (1,0 % MW + 0,5 % MEW)
Repeatability± 0,2 % MEW
Accuracy[K] [K]± 2,5 (Q > 5 % MEW)
Temperature coefficient[% of the span / 10 K] [% of the span / 10 K]0,2

Response times

Response time[s] [s]< 0.25; (dAP = 0, T09)
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]5,7 / 86

Software / programming

Diagnostic functionsdirection of flow detection; signal quality

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1.3
SDCI standardIEC 61131-9: 2013-07
ProfilesBLOB; Binary Large Object transfer; Common - I&D; Identification and Diagnosis
BLOBBinary Large Object transfer
Common - I&DIdentification and Diagnosis
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time[ms] [ms]9.6
IO-Link process data (cyclical)totaliser; 32; Flow monitoring; 32; Temperature monitoring; 32; status; 4; Output 1; 1; Output 2; 1
totaliser32
Flow monitoring32
Temperature monitoring32
status4
Output 11
Output 21
Supported DeviceIDsdefault; 1759
default1759

Operating conditions

Ambient temperature[°C] [°C]-20...60
Storage temperature[°C] [°C]-25...80
ProtectionIP 67

Tests / approvals

EMCDIN 61326-1:2021
Shock resistanceDIN IEC 68-2-27; 20 g (11ms)
DIN IEC 68-2-2720 g (11ms)
Vibration resistanceDIN IEC 68-2-6; 20 g (10...2000Hz)
DIN IEC 68-2-620 g (10...2000Hz)
MTTF[years] [years]160
UL approvalUL approval no.; I034
UL approval no.I034
Pressure Equipment Directivecan be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]623.4
Housingrectangular
Type of mountinginlet pipe length 5xDN; outlet pipe length 1xDN
Dimensions[mm] [mm]162.6 x 48 x 65.2
Materialshousing: stainless steel (316L/1.4404); Display: PFA; Sealing Display: FKM; connector: PBT
Materials (wetted parts)Pipe section: stainless steel (316L/1.4404)
Process connectionthreaded connection 1" NPT external thread DN25
Surface characteristics Ra/Rz of the wetted parts49.21 µin

Displays / operating elements

Displaycolour display 1,44", 128 x 128 pixels; Switching function; 2 x LED, yellow; diagnosis; 1 x LED, three-colour
Switching function2 x LED, yellow
diagnosis1 x LED, three-colour
Display unitl/min; l/h; m³/h; m/s; gpm; gph; ft/s; oz/min

Accessories

Items suppliedpackage insert

Remarks

RemarksMW = measured value; MEW = Final value of the measuring range; pulse and totaliser signal are only available for one of the two outputs; the accuracy indications are adhered to over the entire application area
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote