B&R X20PS9600 – Power supply module, 24 VDC power supply module for…
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | System modules for Compact-S PLC |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can X20PS9600 be shipped?
X20PS9600 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20PS9600 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20PS9600 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20PS9600, subject to availability and destination.
• Supply for Compact-S CPU, X2X Link and internal I/O power supply
• Galvanic isolation of supply and CPU / X2X Link power supply
• Redundancy of the CPU / X2X Link power supply possible through parallel operation of multiple power supply modules
• RS232 configurable as an online interface
• CAN bus
The power supply module is used together with an X20 Compact-S PLC. It has a feed for the Compact-S PLC, X2X Link and the internal I/O power supply.
Accessories
Required accessories (order separately)
| X20cBB57 | System modules for Compact-S PLC — Base for all X20 Compact-S CPUs; RS232 connection; CAN bus connection; Integrated terminating resistor for CAN bus |
| X20cBB52 | System modules for Compact-S PLC — Base for all X20 Compact-S CPUsRS232 connection The bus module is the base for all X20 Compact-S controllers. The left and right end cover… |
| X20BB77 | System modules for Compact-S PLC — Base for X20 Compact-S controllers; 2 slots for X20 interface modules; RS232 connection; CAN bus connection; Integrated terminating resisto… |
| X20BB72 | System modules for Compact-S PLC — Base for X20 Compact-S controllers; 2 slots for X20 interface modules; RS232 connection The bus module is a base for all X20 Compact-S cont… |
| X20BB67 | System modules for Compact-S PLC — Base for X20 Compact-S controllers; 1 slot for X20 interface modules; RS232 connection; CAN bus connection; Integrated terminating resistor… |
| X20BB63 | System modules for Compact-S PLC — Base for X20 Compact-S controllers; 1 slot for X20 interface modules; RS485 connection; Integrated terminating resistor The bus base is a b… |
| X20BB62 | System modules for Compact-S PLC — Base for X20 Compact-S controllers; 1 slot for X20 interface modules; RS232 connection The bus module is the base for all X20CP048x Compact… |
| X20BB57 | System modules for Compact-S PLC — Base for all X20 Compact-S controllers; RS232 connection; CAN bus connection; Integrated terminating resistor for CAN bus The bus module is… |
| X20BB53 | System modules for Compact-S PLC — Base for all X20 Compact-S controllers; RS485 connection; Integrated terminating resistor The bus base is the basis for all X20 Compact-S c… |
| X20BB52 | System modules for Compact-S PLC — Base for all X20 Compact-S controllers; RS232 connection The bus module is the base for all X20 Compact-S controllers. The left and right e… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Specifications
Short description
| Power supply module | 24 VDC power supply module for Compact-S PLC, X2X Link power supply and I/O |
| Interfaces | 1x RS232, 1x RS485, 1x CAN bus " data-placement="top" data-html="true" data-container="body" data-content="RS232 interface only in connection with bus module X20BBx2 or X20BBx7.<br>RS485 interface only in connection with bus module X20BB53 or X20BB63.<br>CAN bus only in connection with bus module X20BB57, X20BB67 or X20BB77."> |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – CAN bus data transfer " data-placement="top" data-html="true" data-container="body" data-content="CAN bus only when used with bus module X20BB57, X20BB67 or X20BB77."> | Yes, using LED status indicator |
| Diagnostics – RS232 data transfer " data-placement="top" data-html="true" data-container="body" data-content="RS232 interface only in connection with bus module X20BBx2 or X20BBx7."> | Yes, using LED status indicator |
| Diagnostics – RS485 data transfer " data-placement="top" data-html="true" data-container="body" data-content="RS485 interface only in connection with bus module X20BB53 or X20BB63."> | Yes, using LED status indicator |
| Diagnostics – Overload | Yes, using LED status indicator and software |
| Power consumption " data-placement="top" data-html="true" data-container="body" data-content="The specified values are maximum values. For examples of the exact calculation, see section "Mechanical and electrical configuration" in the X20 system user's manual."> – Internal I/O | 0.6 W |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – CCS | Yes |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| B&R ID code | 0xEB03 |
| Status indicators | Overload, operating state, module status, RS232, RS485, CAN bus " data-placement="top" data-html="true" data-container="body" data-content="RS232 interface only in connection with bus module X20BBx2 or X20BBx7.<br>RS485 interface only in connection with bus module X20BB53 or X20BB63.<br>CAN bus only in connection with bus module X20BB57, X20BB67 or X20BB77."> |
| Power consumption for X2X Link power supply " data-placement="top" data-html="true" data-container="body" data-content="The specified values are maximum values. For examples of the exact calculation, see section "Mechanical and electrical configuration" in the X20 system user's manual."> | 1.42 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
CPU / X2X Link power supply input
| Input voltage | 24 VDC -15% / +20% |
| Input current | Max. 0.7 A |
| Fuse | Integrated, cannot be replaced |
| Reverse polarity protection | Yes |
CPU / X2X Link power supply output
| Nominal output power | 7 W |
| Parallel connection | Yes " data-placement="top" data-html="true" data-container="body" data-content="In parallel operation, it is only permitted to expect 75% of the nominal power. It is important to make sure that all power supplies operated in parallel are switched on and off at the same time."> |
| Redundant operation | Yes |
| Overload characteristics | Short-circuit proof, temporary overload |
Input I/O power supply
| Input voltage | 24 VDC -15% / +20% |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection | No |
Output I/O power supply
| Nominal output voltage | 24 VDC |
| Behavior on short circuit | Required line fuse |
| Permissible contact load | 10 A |
Interfaces
| Interface IF1 – Signal | RS232 or RS485 " data-placement="top" data-html="true" data-container="body" data-content="RS232 interface only in connection with bus module X20BBx2 or X20BBx7.<br>RS485 interface only in connection with bus module X20BB53 or X20BB63."> |
| Interface IF1 – Variant | Connection made using 12-pin terminal block X20TB12 |
| Interface IF1 – Transfer rate | Max. 115.2 kbit/s |
| Interface IF3 – Signal | CAN bus " data-placement="top" data-html="true" data-container="body" data-content="CAN bus only in connection with bus module X20BB57, X20BB67 or X20BB77."> |
| Interface IF3 – Variant | Connection made using 12-pin terminal block X20TB12 |
| Interface IF3 – Transfer rate | Max. 1 Mbit/s |
Electrical properties
| Electrical isolation | PLC/X2X Link supply isolated from PLC/X2X Link power supply; I/O supply not isolated from I/O power supply |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | See section "Derating". |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately.; Order 1x Compact-S PLC base X20BB5x, X20BB6x or X20BB7x separately. |
| Pitch | 12.5 +0.2 mm |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| Data sheet X20(c)PS9600 | PDF · 724 KB · 1.25 (07/30/2025) - EN |
| X20 System User´s Manual | PDF · 50 MB · 4.40 (03/10/2026) - EN |
CAD & dimension drawings
| 3D File DXF/STEP X20 Electronic module | ZIP · 10 KB · 1.0 (10/17/2005) |
| 3D File STEP X20 I/O-Slice | ZIP · 872 KB · 1.1 (03/13/2019) |
| Dimensions PDF X20 Electronic module | PDF · 3 KB · 1.0 (10/17/2005) |
Certificates (11)
| 64331_A1 BV Certificate of Compliance X20 | PDF · 1 MB · 2026_05 (05/05/2026) |
| ABS Certificate of Product Design Assessment - X20 IO Series | PDF · 454 KB · 2.00 (01/13/2025) |
| CCS Type Approval Certificate - X20 | PDF · 285 KB · 1.00 (06/28/2024) |
| E115267 UL Certificate of Compliance X20 | PDF · 3 MB · 2026_08_27 (08/27/2026) |
| EU Declaration ATEX X20 | PDF · 218 KB · 2023-07 (09/05/2023) |
| EU Declaration of conformity PLC X20 | PDF · 169 KB · 2021/10 (11/08/2021) |
| KR Type Approval Certificate MIL39390-AC003 (X20 System) | PDF · 320 KB · 2.0 (05/05/2025) |
| Lloyds Register (X20 only) | PDF · 884 KB · 1.30 (07/07/2025) |
| RINA Type Approval Certificate - X20 / Power Panel T30 | PDF · 1 MB · 1.00 (05/07/2021) |
| TAA00000BJ DNV Type Approval Certificate X20 | PDF · 186 KB · 13.0 (05/04/2026) |
| UK Declaration PLC X20 | PDF · 151 KB · 2024-01 (01/18/2024) |
More B&R parts
Available on requestB&R X20PS9400 – Power supply module, 24 VDC supply module for bus…
Available on requestB&R X20PS9402 – Power supply module, 24 VDC supply module for bus…
Available on requestB&R X20PS9500 – Power supply module, 24 VDC power supply module for Compact…
Available on requestB&R X20PS9502 – Power supply module, 24 VDC power supply module for Compact…
Available on requestB&R X20PS9602 – Power supply module, 24 VDC power supply module for…
Available on requestB&R X20RT8001 – I/O module, 4 digital input channels
Available on requestB&R X20RT8201 – I/O module, 4 digital input channels
Available on requestB&R X20RT8202 – I/O module, 4 digital input channels