B&R X20PS9402 – Power supply module, 24 VDC supply module for bus…
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | System modules for bus controllers |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can X20PS9402 be shipped?
X20PS9402 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20PS9402 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20PS9402 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20PS9402, subject to availability and destination.
• Supply for the bus controller, X2X Link and internal I/O supply
• Low-cost supply module for small X20 system
• Feed and bus controller / X2X Link supply not electrically isolated
• Expansion or redundancy of bus controller / X2X Link supply not possible by operating multiple supply modules simultaneously
The supply module is used together with an X20 bus controller. It is equipped with a feed for the bus controller, the X2X Link and the internal I/O supply.
The module is designed to supply power for smaller X20 systems. Potential groups are able to be formed. An expansion or redundancy of the X2X Link with the X20PS3300 or X20PS3310 supply module is not possible. Expansion of the X20 system with a bus transmitter is not permitted either.
Accessories
Required accessories (order separately)
| X20BB80 | System modules for bus controllers — Bus base The following modules are used on the bus module: Base module (BC, HB, etc.); Supply module The left and right end cover plates ar… |
| X20BB82 | System modules for expandable bus controllers — Bus base with 2 expansion slots The bus module has 2 expansion slots. The following modules are used on this module: Base module (BC, HB, e… |
| X20BB81 | System modules for expandable bus controllers — Bus base with one expansion slot The bus module has an expansion slot. The following modules are used on this module: Base module (BC, HB,… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Specifications
Short description
| Power supply module | 24 VDC supply module for bus controller, X2X Link power supply and I/O |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – Overload | Yes, using LED status indicator and software |
| Power consumption " data-placement="top" data-html="true" data-container="body" data-content="The specified values are maximum values. For examples of the exact calculation, see section "Mechanical and electrical configuration" in the X20 system user's manual."> – Internal I/O | 0.6 W |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – CCS | Yes |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| Certifications – KC | Yes |
| B&R ID code | 0xA389 |
| Status indicators | Operating state, module status |
| Power consumption for X2X Link power supply " data-placement="top" data-html="true" data-container="body" data-content="The specified values are maximum values. For examples of the exact calculation, see section "Mechanical and electrical configuration" in the X20 system user's manual."> | 1.64 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Bus controller / X2X Link power supply input
| Input voltage | 24 VDC -15% / +20% |
| Input current | Max. 0.7 A |
| Fuse | Integrated, cannot be replaced |
| Reverse polarity protection | Yes |
Bus controller / X2X Link power supply output
| Nominal output power – Horizontal mounting orientation | 7 W at 45°C and 5 W at 55°C |
| Nominal output power – Vertical mounting orientation | 7 W at 40°C and 5 W at 50°C |
| Parallel connection | No |
| Redundant operation | No |
| Overload characteristics | Short-circuit proof, temporary overload |
Input I/O power supply
| Input voltage | 24 VDC -15% / +20% |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection | No |
Output I/O power supply
| Nominal output voltage | 24 VDC |
| Behavior on short circuit | Required line fuse |
| Permissible contact load | 10 A |
Electrical properties
| Electrical isolation | BC/X2X Link supply not isolated from BC/X2X Link power supply, and I/O supply not isolated from I/O power supply |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | See section "Derating". |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately.; Order 1x bus base X20BB8x separately. |
| Pitch | 12.5 +0.2 mm |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| Data sheet X20PS9402 | PDF · 717 KB · 3.10 (07/30/2025) - EN |
| X20 Package leaflet ATEX/CSA | PDF · 2 MB · 1.4 (09/17/2024) |
| X20 System User´s Manual | PDF · 50 MB · 4.40 (03/10/2026) - EN |
CAD & dimension drawings
| 3D File DXF/STEP X20 Electronic module | ZIP · 10 KB · 1.0 (10/17/2005) |
| 3D File STEP X20 I/O-Slice | ZIP · 872 KB · 1.1 (03/13/2019) |
| Dimensions PDF X20 Electronic module | PDF · 3 KB · 1.0 (10/17/2005) |
Certificates (15)
More B&R parts
Available on requestB&R X20PS3310 – Power supply module, 24 VDC supply module for I/O and bus
Available on requestB&R X20PS4951 – System module, power supply of 4 potentiometers with ±10 V
Available on requestB&R X20PS8002 – Power supply module, 24 VDC power supply module for X20…
Available on requestB&R X20PS9400 – Power supply module, 24 VDC supply module for bus…
Available on requestB&R X20PS9500 – Power supply module, 24 VDC power supply module for Compact…
Available on requestB&R X20PS9502 – Power supply module, 24 VDC power supply module for Compact…
Available on requestB&R X20PS9600 – Power supply module, 24 VDC power supply module for…
Available on requestB&R X20PS9602 – Power supply module, 24 VDC power supply module for…