B&R X20PS9502 – Power supply module, 24 VDC power supply module for Compact…
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can X20PS9502 be shipped?
X20PS9502 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20PS9502 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20PS9502 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20PS9502, subject to availability and destination.
• Supply for Compact or Fieldbus CPU, X2X Link network and internal I/O power supply
• Cost-effective power supply module for small X20 systems
• No electrical isolation of supply and CPU / X2X Link power supply
• Expansion or redundancy of CPU / X2X Link power supply not possible by operating multiple power supply modules simultaneously
• RS232 configurable as an online interface
• CAN bus
The power supply module is used together with an X20 Compact or Fieldbus CPU. It is equipped with a supply for the Compact or Fieldbus CPU, X2X Link network and internal I/O power supply.
This module is intended as a cost-effective power supply module for small X20 systems. The use of potential groups is possible. Expansion or redundancy of the X2X Link network with power supply module X20PS3300 or X20PS3310 is not possible. Expanding the X20 system with a bus transmitter is also not permitted.
Accessories
Required accessories (order separately)
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
| X20BB47 | Undefined — Base for all X20 Fieldbus CPUs; 2 slots for interface modules; RS232 connection; CAN bus connection; Integrated terminating resistor for CA… |
| X20BB42 | Undefined — Base for all X20 Fieldbus CPUs; 2 slots for interface modules; RS232 connection The bus module is a base for all X20 Fieldbus CPUs. It is e… |
| X20BB37 | Undefined — Base for all X20 Fieldbus CPUs; RS232 connection; CAN bus connection; Integrated terminating resistor for CAN bus The bus module is the bas… |
| X20BB32 | Undefined — Base for all X20 Fieldbus CPUs; RS232 connection The bus module is the base for all X20 Fieldbus CPUs. The left and right end cover plates… |
| X20BB27 | Undefined — Base for all X20 Compact CPUs; RS232 connection; CAN bus connection; Integrated terminating resistor for CAN bus The bus module is the base… |
| X20BB22 | Undefined — Base for all X20 Compact CPUs; RS232 connection The bus module is the base for all X20 Compact CPUs. The left and right end cover plates ar… |
Specifications
Short description
| Power supply module | 24 VDC power supply module for Compact or Fieldbus CPU, X2X Link power supply and I/O |
| Interfaces | 1x RS232, 1x CAN bus " data-placement="top" data-html="true" data-container="body" data-content="CAN bus only in connection with bus module X20BB27 or X20BB37."> |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – CAN bus data transfer " data-placement="top" data-html="true" data-container="body" data-content="CAN bus only in connection with bus module X20BB27 or X20BB37."> | Yes, using LED status indicator |
| Diagnostics – RS232 data transfer | Yes, using LED status indicator |
| Diagnostics – Overload | Yes, using LED status indicator and software |
| Power consumption " data-placement="top" data-html="true" data-container="body" data-content="The specified values are maximum values. For examples of the exact calculation, see section "Mechanical and electrical configuration" in the X20 system user's manual."> – Internal I/O | 0.6 W |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – CCS | Yes |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| Certifications – KC | Yes |
| B&R ID code | 0xA38A |
| Status indicators | Operating state, module status, RS232, CAN bus " data-placement="top" data-html="true" data-container="body" data-content="CAN bus only in connection with bus module X20BB27 or X20BB37."> |
| Power consumption for X2X Link power supply " data-placement="top" data-html="true" data-container="body" data-content="The specified values are maximum values. For examples of the exact calculation, see section "Mechanical and electrical configuration" in the X20 system user's manual."> | 1.64 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
CPU / X2X Link power supply input
| Input voltage | 24 VDC -15% / +20% |
| Input current | Max. 0.7 A |
| Fuse | Integrated, cannot be replaced |
| Reverse polarity protection | Yes |
CPU / X2X Link power supply output
| Nominal output power – Horizontal mounting orientation | 7 W at 45°C and 5 W at 55°C |
| Nominal output power – Vertical mounting orientation | 7 W at 40°C and 5 W at 50°C |
| Parallel connection | No |
| Redundant operation | No |
| Overload characteristics | Short-circuit proof, temporary overload |
Input I/O power supply
| Input voltage | 24 VDC -15% / +20% |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection | No |
Output I/O power supply
| Nominal output voltage | 24 VDC |
| Behavior on short circuit | Required line fuse |
| Permissible contact load | 10 A |
Interfaces
| Interface IF1 – Signal | RS232 |
| Interface IF1 – Variant | Connection via 12-pin terminal block X20TB12 |
| Interface IF1 – Transfer rate | Max. 115.2 kbit/s |
| Interface IF3 " data-placement="top" data-html="true" data-container="body" data-content="CAN bus only in connection with bus module X20BB27 or X20BB37."> – Signal | CAN bus |
| Interface IF3 " data-placement="top" data-html="true" data-container="body" data-content="CAN bus only in connection with bus module X20BB27 or X20BB37."> – Variant | Connection via 12-pin terminal block X20TB12 |
| Interface IF3 " data-placement="top" data-html="true" data-container="body" data-content="CAN bus only in connection with bus module X20BB27 or X20BB37."> – Transfer rate | Max. 1 Mbit/s |
Electrical properties
| Electrical isolation | CPU/X2X Link supply not isolated from CPU/X2X Link power supply, and I/O supply not isolated from I/O power supply |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | See section "Derating". |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately. ; Order 1x Compact CPU base X20BB22 or X20BB27 separately ; Order 1x Fieldbus CPU base X20BB32 or X20BB37 separately |
| Pitch | 12.5 +0.2 mm |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| Data sheet X20PS9502 | PDF · 199 KB · 3.07 (10/18/2019) - EN |
| X20 Package leaflet ATEX/CSA | PDF · 2 MB · 1.4 (09/17/2024) |
| X20 System User´s Manual | PDF · 50 MB · 4.40 (03/10/2026) - EN |
CAD & dimension drawings
| 3D File DXF/STEP X20 Electronic module | ZIP · 10 KB · 1.0 (10/17/2005) |
| 3D File STEP X20 I/O-Slice | ZIP · 872 KB · 1.1 (03/13/2019) |
| Dimensions PDF X20 Electronic module | PDF · 3 KB · 1.0 (10/17/2005) |
Certificates (11)
| 2226379 CSA Certificate of Compliance X20 X67 | PDF · 205 KB · 2026_09 (09/21/2026) |
| 64331_A1 BV Certificate of Compliance X20 | PDF · 1 MB · 2026_05 (05/05/2026) |
| ABS Certificate of Product Design Assessment - X20 IO Series | PDF · 454 KB · 2.00 (01/13/2025) |
| CCS Type Approval Certificate - X20 | PDF · 285 KB · 1.00 (06/28/2024) |
| E115267 UL Certificate of Compliance X20 | PDF · 3 MB · 2026_08_27 (08/27/2026) |
| FTZU 09 ATEX 0083X | PDF · 771 KB · 3.00 (10/12/2021) |
| KR Type Approval Certificate MIL39390-AC003 (X20 System) | PDF · 320 KB · 2.0 (05/05/2025) |
| Lloyds Register (X20 only) | PDF · 884 KB · 1.30 (07/07/2025) |
| RINA Type Approval Certificate - X20 / Power Panel T30 | PDF · 1 MB · 1.00 (05/07/2021) |
| TAA00000BJ DNV Type Approval Certificate X20 | PDF · 186 KB · 13.0 (05/04/2026) |
| X20, X67 KC certificates | PDF · 7 MB · 2.00 (08/17/2026) |
More B&R parts
Available on requestB&R X20PS8002 – Power supply module, 24 VDC power supply module for X20…
Available on requestB&R X20PS9400 – Power supply module, 24 VDC supply module for bus…
Available on requestB&R X20PS9402 – Power supply module, 24 VDC supply module for bus…
Available on requestB&R X20PS9500 – Power supply module, 24 VDC power supply module for Compact…
Available on requestB&R X20PS9600 – Power supply module, 24 VDC power supply module for…
Available on requestB&R X20PS9602 – Power supply module, 24 VDC power supply module for…
Available on requestB&R X20RT8001 – I/O module, 4 digital input channels
Available on requestB&R X20RT8201 – I/O module, 4 digital input channels