Available on request

B&R X20AO2437 – I/O module, 2 analog outputs 4 to 20 mA

MPN: X20AO2437 · Brand: B&R
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryAnalog outputs
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)
DatasheetManufacturer datasheet ↗

Shipping & availability

When can X20AO2437 be shipped?

X20AO2437 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X20AO2437 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X20AO2437 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20AO2437, subject to availability and destination.

• 2 analog current outputs

• Electrically isolated analog channels

• 16-bit digital converter resolution

The module is equipped with 2 current outputs with 16-bit digital converter resolution. The 2 channels are electrically isolated from each other. The user can select between the 3 output ranges 4 to 20 mA , 0 to 20 mA and 0 to 24 mA .

Accessories

Required accessories (order separately)

X20BM15Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe…
X20BM11Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module…
X20TB12Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…

Specifications

Short description

I/O module2 analog outputs 4 to 20 mA, 0 to 20 mA or 0 to 24 mA

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – OutputsYes, using LED status indicator and software
Power consumption – Bus0.05 W
Power consumption – Internal I/O1.6 W
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ATEXZone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – DNVTemperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
Certifications – CCSYes
Certifications – LRENV1
Certifications – KRYes
Certifications – ABSYes
Certifications – BVEC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck
Certifications – KCYes
B&R ID code0xB785
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-

Analog outputs

Max. error " data-placement="top" data-html="true" data-container="body" data-content="At 25°C"> – 4 to 20 mA±0.025% " data-placement="top" data-html="true" data-container="body" data-content="Based on the current output value.">
Max. error " data-placement="top" data-html="true" data-container="body" data-content="At 25°C"> – 0 to 20 mA±0.022% " data-placement="top" data-html="true" data-container="body" data-content="Based on the current output value.">
Max. error " data-placement="top" data-html="true" data-container="body" data-content="At 25°C"> – 0 to 24 mA±0.02% " data-placement="top" data-html="true" data-container="body" data-content="Based on the current output value.">
Max. error " data-placement="top" data-html="true" data-container="body" data-content="At 25°C"> – 4 to 20 mA±0.025% " data-placement="top" data-html="true" data-container="body" data-content="Based on the respective output range.">
Max. error " data-placement="top" data-html="true" data-container="body" data-content="At 25°C"> – 0 to 20 mA±0.022% " data-placement="top" data-html="true" data-container="body" data-content="Based on the respective output range.">
Max. error " data-placement="top" data-html="true" data-container="body" data-content="At 25°C"> – 0 to 24 mA±0.02% " data-placement="top" data-html="true" data-container="body" data-content="Based on the respective output range.">
Output format – 4 to 20 mAINT 0x0000 to 0x7FFF / 1 LSB = 0x0001 = 488.281 nA
Output format – 0 to 20 mAINT 0x0000 to 0x7FFF / 1 LSB = 0x0001 = 610.352 nA ; UINT 0x0000 to 0xFFFF / 1 LSB = 0x0001 = 305.176 nA
Output format – 0 to 24 mAINT 0x0000 to 0x5DC0 / 1 LSB = 0x0001 = 1000 nA
Max. gain drift – 4 to 20 mA±0.0055%/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the current output value.">
Max. gain drift – 0 to 20 mA±0.005%/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the current output value.">
Max. gain drift – 0 to 24 mA±0.005%/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the current output value.">
Max. offset drift – 4 to 20 mA±0.0035%/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the respective output range.">
Max. offset drift – 0 to 20 mA±0.002%/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the respective output range.">
Max. offset drift – 0 to 24 mA±0.002%/°C " data-placement="top" data-html="true" data-container="body" data-content="Based on the respective output range.">
Error caused by load change " data-placement="top" data-html="true" data-container="body" data-content="Load change from 1 Ω → 600 Ω, resistive"> – 4 to 20 mA0.14%
Error caused by load change " data-placement="top" data-html="true" data-container="body" data-content="Load change from 1 Ω → 600 Ω, resistive"> – 0 to 20 mA0.1%
Error caused by load change " data-placement="top" data-html="true" data-container="body" data-content="Load change from 1 Ω → 600 Ω, resistive"> – 0 to 24 mA0.1%
Test voltage – Channel - Channel1000 VAC
Test voltage – Channel - Bus1000 VAC
Test voltage – Channel - Ground1000 VAC
Output4 to 20 mA, 0 to 20 mA or 0 to 24 mA configurable using software
Digital converter resolution16-bit
Settling time on output change over entire range2 ms to 20 s, configurable using software
Data output rate1 ms without ramp
Output protectionShort-circuit proof, overvoltage protection (up to 30 VDC)
Open-circuit detectionYes, using hardware and software
Data formatINT
Load per channelMax. 600 Ω
Short-circuit proofYes, continuous
Output filterActive second-order low-pass filter / Cutoff frequency 4 kHz; Configurable slew rate
Nonlinearity<0.003% " data-placement="top" data-html="true" data-container="body" data-content="Based on the entire output range.">

Electrical properties

Electrical isolationChannel isolated from channel and bus

Operating conditions

Mounting orientation – HorizontalYes
Mounting orientation – VerticalYes
Installation elevation above sea level – 0 to 2000 mNo limitation
Installation elevation above sea level – >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Horizontal mounting orientation-25 to 60°C
Temperature – Vertical mounting orientation-25 to 50°C
Temperature – DeratingSee section "Derating".
Temperature – Storage-40 to 85°C
Temperature – Transport-40 to 85°C
Relative humidity – Operation5 to 95%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

NoteOrder 1x terminal block X20TB12 separately. ; Order 1x bus module X20BM11 separately.
Pitch12.5 +0.2 mm

Downloads & documentation

Official documents from B&R, downloaded directly from the manufacturer.

Data sheets & manuals

Datasheet X20(c)AO2437PDF · 786 KB · 1.40 (05/26/2025) - EN
X20 Package leaflet ATEX/CSAPDF · 2 MB · 1.4 (09/17/2024)
X20 System User´s ManualPDF · 50 MB · 4.40 (03/10/2026) - EN

CAD & dimension drawings

3D File DXF/STEP X20 Electronic moduleZIP · 10 KB · 1.0 (10/17/2005)
3D File STEP X20 I/O-SliceZIP · 872 KB · 1.1 (03/13/2019)
Dimensions PDF X20 Electronic modulePDF · 3 KB · 1.0 (10/17/2005)
Certificates (15)
2226379 CSA Certificate of Compliance X20 X67PDF · 205 KB · 2026_09 (09/21/2026)
64331_A1 BV Certificate of Compliance X20PDF · 1 MB · 2026_05 (05/05/2026)
ABS Certificate of Product Design Assessment - X20 IO SeriesPDF · 454 KB · 2.00 (01/13/2025)
CCS Type Approval Certificate - X20PDF · 285 KB · 1.00 (06/28/2024)
E115267 UL Certificate of Compliance X20PDF · 3 MB · 2026_08_27 (08/27/2026)
EU Data Act - X20 IO - Connected Product Information NoticePDF · 92 KB · 1.00 (09/30/2025)
EU Declaration ATEX X20PDF · 218 KB · 2023-07 (09/05/2023)
EU Declaration of conformity PLC X20PDF · 169 KB · 2021/10 (11/08/2021)
FTZU 09 ATEX 0083XPDF · 771 KB · 3.00 (10/12/2021)
KR Type Approval Certificate MIL39390-AC003 (X20 System)PDF · 320 KB · 2.0 (05/05/2025)
Lloyds Register (X20 only)PDF · 884 KB · 1.30 (07/07/2025)
RINA Type Approval Certificate - X20 / Power Panel T30PDF · 1 MB · 1.00 (05/07/2021)
TAA00000BJ DNV Type Approval Certificate X20PDF · 186 KB · 13.0 (05/04/2026)
UK Declaration PLC X20PDF · 151 KB · 2024-01 (01/18/2024)
X20, X67 KC certificatesPDF · 7 MB · 2.00 (08/17/2026)
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More B&R parts

B&R X20AI8221 – I/O module, 8 analog inputs ±10 VAvailable on requestB&R X20AI8221 – I/O module, 8 analog inputs ±10 V
MPN: X20AI8221 · B&R
Price on request
Request a quote
B&R X20AI8321 – I/O module, 8 analog inputs 0 to 20 mA / 4 to 20 mAAvailable on requestB&R X20AI8321 – I/O module, 8 analog inputs 0 to 20 mA / 4 to 20 mA
MPN: X20AI8321 · B&R
Price on request
Request a quote
B&R X20AIA744 – I/O module, 2 full-bridge strain gauge inputsAvailable on requestB&R X20AIA744 – I/O module, 2 full-bridge strain gauge inputs
MPN: X20AIA744 · B&R
Price on request
Request a quote
B&R X20AIB744 – I/O module, 4 full-bridge strain gauge inputsAvailable on requestB&R X20AIB744 – I/O module, 4 full-bridge strain gauge inputs
MPN: X20AIB744 · B&R
Price on request
Request a quote
B&R X20AO2438 – I/O module, 2 analog outputs 4 to 20 mAAvailable on requestB&R X20AO2438 – I/O module, 2 analog outputs 4 to 20 mA
MPN: X20AO2438 · B&R
Price on request
Request a quote
B&R X20AO2632 – I/O module, 2 analog outputs ±10 V or 0 to 20 mAAvailable on requestB&R X20AO2632 – I/O module, 2 analog outputs ±10 V or 0 to 20 mA
MPN: X20AO2632 · B&R
Price on request
Request a quote
B&R X20AO2632-1 – I/O module, 2 analog outputs ±11 V or 0 to 22 mAAvailable on requestB&R X20AO2632-1 – I/O module, 2 analog outputs ±11 V or 0 to 22 mA
MPN: X20AO2632-1 · B&R
Price on request
Request a quote