Fail-safe 8-channel digital input; 24 VDC; PROFIsafe V2.0 iPar
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | I/O Systems |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 750-662/000-003 be shipped?
750-662/000-003 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 750-662/000-003 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 750-662/000-003 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 750-662/000-003, subject to availability and destination.
This PROFIsafe Module (75x-662/000-003) connects to potential-free emergency stop buttons with contacts, safety interlock switches, operating mode switches, safety sensors and semiconductor outputs.<br/>The module features eight clock-sensitive inputs (I1 … I8) that are fed via two differently clocked outputs (T1 … T2).<br/><p>Clock outputs are short-circuit-protected. Inputs are continually monitored for cross circuits and power supply from separate sources. Additional safety-relevant parameters (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-<i>CHECK</i>.</p><p>The configuration tool can be conveniently integrated into engineering systems supporting both CC2 and CC3 tool calling interfaces (TCI).</p><p>When exchanging modules, parameters are automatically downloaded into the control unit via PROFIsafe-compatible iPar server – depending on settings. The PROFIsafe address can be set using the DIP switch located on the side of the module, or via WAGO-I/O-<i>CHECK</i>.</p><p>The module supports both PROFIsafe V1 (PROFIBUS) and V2 (PROFIBUS, PROFINET) protocols. </p><p>Field and system levels are electrically isolated. </p>Safety modules can be arranged in any combination when configuring the fieldbus node.<br/><b>To protect the module against impulse voltages (over-voltage protection per IEC 61000-4-5), a WAGO Filter Module or an external surge filter must be used for the 24V supply voltage.</b><br/><p><b>Additional information can be found in the product manual (available in German and English).</b></p>
Specifications
General technical data
| Protocols | PROFIsafe V2 |
| Configuration options | PROFIsafe address adjustable via DIP switch or engineering software |
| Indicators | LED (A-D) green/red: Status/Error I1 … I8; LED (E) red: Group error; LED (F-H) green/red: Diagnostics |
| Total number of channels (module) | 8 |
| Pluggable connector | fixed |
Digital Inputs
| Number of digital inputs | 8 |
| Signal type | Digital |
| Signal type (voltage) | 24 VDC |
| Sensor connection | 8 x (Fail-safe input with test pulse) |
| Input characteristic | clock sensitive |
| Input characteristic | Type 1 per IEC 61131 |
| Input current per channel for signal (1) typ. | 2.2 mA |
| Signal frequency (max.) | 50 Hz |
Digital Clock Outputs
| Signal type | Digital |
| Signal type (voltage) | 24 VDC |
Digital outputs
| Signal type | Digital |
| Signal type (voltage) | 24 VDC |
Technical data
| Supply voltage (system) | 5 VDC; via data contacts |
| Current consumption (5 V system supply) | 148 mA |
| Supply voltage (field) | 24 VDC, SELV/PELV (-15 … +20 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact) |
| Current consumption, field supply (module with no external load) | 20 mA |
| Isolation | 500 V system/field |
| Number of incoming power jumper contacts | 2 |
| Number of outgoing power jumper contacts | 2 |
| Current carrying capacity (power jumper contacts) | 10 A |
Functional Safety
| Achievable safety classes | SIL 3; Category 4, PL e |
| Safety standards | IEC 61508-1 … -7; EN ISO 13849-1; EN 62061 |
Connection data
| Connection technology: I/O | 16 x CAGE CLAMP® |
| Connection type | Inputs/outputs |
| Solid conductor | 0.08 … 2.5 mm² / 28 … 14 AWG |
| Fine-stranded conductor | 0.08 … 2.5 mm² / 28 … 14 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
Physical data
| Width | 24 mm / 0.945 inches |
| Height | 100 mm / 3.937 inches |
| Depth | 67.8 mm / 2.669 inches |
| Depth from upper-edge of DIN-rail | 60.6 mm / 2.386 inches |
Mechanical data
| Mounting type | DIN-35 rail |
| Pluggable connector | fixed |
Material data
| Color | yellow |
| Housing material | Polycarbonate; polyamide 6.6 |
| Fire load | 1.946 MJ |
| Weight | 98.5 g |
| Conformity marking | CE |
Environmental requirements
| Ambient temperature (operation) | 0 … +55 °C |
| Ambient temperature (storage) | -25 … +85 °C |
| Protection type | IP20 |
| Pollution degree | 2 per IEC 61131-2 |
| Operating altitude | 0 … 2000 m / 0 … 6562 ft |
| Mounting position | Horizontal left, horizontal right, horizontal top, vertical top and vertical bottom |
| Relative humidity (without condensation) | 95 % |
| Vibration resistance | 4g per IEC 60068-2-6 |
| Shock resistance | 15g per IEC 60068-2-27 |
| EMC immunity to interference | per EN 61000-6-2, marine applications |
| EMC emission of interference | per EN 61000-6-4, marine applications |
| Exposure to pollutants | per IEC 60068-2-42 and IEC 60068-2-43 |
| Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 % | 10 ppm |
| Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 % | 25 ppm |
Commercial data
| Product Group | 15 (I/O System) |
| PU (SPU) | 1 pcs |
| Packaging type | Box |
| Country of origin | DE |
| GTIN | 4050821038740 |
| Customs tariff number | 85389099990 |
Product Classification
| UNSPSC | 32151705 |
| eCl@ss 10.0 | 27-24-26-04 |
| eCl@ss 9.0 | 27-24-26-04 |
| ETIM 9.0 | EC001599 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 1303-86-2, 1317-36-8, 7439-92-1, 75980-60-8, 79-94-7, 80-05-7 |
| REACH Candidate List Substance | 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, 4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide, Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)- |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Bulgaria) | afbbe186-25c5-4dea-ae12-c982f3cc3c28 |
| SCIP notification number (Czech Republic) | 1625cbec-ce61-4b84-ae23-3c3ce3cc086e |