Fail-safe 8-channel digital input; 24 VDC; PROFIsafe
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | I/O Systems |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 750-662/000-004 be shipped?
750-662/000-004 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 750-662/000-004 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 750-662/000-004 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 750-662/000-004, subject to availability and destination.
<p>The PROFIsafe Module (75x-662/000-004) connects to potential-free emergency stop buttons with contacts, safety interlock switches, operating mode switches, safety sensors and semiconductor outputs.</p><p>The module features eight clock-sensitive inputs (I1 … I8) that are fed via two differently clocked outputs (T1 … T2).</p><p>Clock outputs are short-circuit-protected. Inputs are continually monitored for cross circuits and power supply from separate sources. Additional safety-relevant parameters (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-<i>CHECK</i>.</p><p>This configuration tool can be conveniently integrated into engineering systems supporting TCI (Tool Calling Interface) with CC2 or CC3.</p><p>When exchanging modules, parameters are automatically downloaded into the control unit via PROFIsafe-compatible iPar server – depending on settings. The PROFIsafe address can be set using the DIP switch located on the side of the module, or via WAGO-I/O-<i>CHECK</i>.</p><p>The module supports both PROFIsafe V2.4 (PROFIBUS, PROFINET) and V2.6 (PROFINET) protocols.</p><p>Field and system levels are electrically isolated.</p><p>Individual safety modules can be arranged in any combination when configuring the fieldbus node.</p><p>If, for example, the cable length of the 24 V supply is greater than 3 m, a WAGO Filter Module or an appropriate external filter must be used for the 24 V power supply to protect the module against surge and burst (per IEC 61000-6-7 and marine applications).</p><p>Additional information can be found in the product manual (available in German and English).</p><p>The 75x-662/000-004 Module has been evaluated by UL in compliance with UL/CSA 61010-1, UL/CSA 61010-2-201 and UL 121201, CSA-C22.2 No. 213.</p><p>The functional safety evaluation was performed by TÜV Rheinland in compliance with the specified standards.</p>
Specifications
General technical data
| Protocols | PROFIsafe V2.6 (PROFINET) and V2.4 (PROFIBUS, PROFINET) |
| Configuration options | PROFIsafe address adjustable via DIP switch or engineering software |
| Indicators | LED (A-D) green/red: Status/Error I1 … I8; LED (E) red: Group error; LED (F-H) green/red: Diagnostics |
| Total number of channels (module) | 8 |
| Pluggable connector | fixed |
Digital Inputs
| Number of digital inputs | 8 |
| Signal type | Digital |
| Signal type (voltage) | 24 VDC |
| Sensor connection | 8 x (Fail-safe input with test pulse) |
| Input characteristic | clock sensitive |
| Input characteristic | Type 1 per IEC 61131 |
| Input current per channel for signal (1) typ. | 3 mA |
| Signal frequency (max.) | 50 Hz |
Digital Clock Outputs
| Signal type | Digital |
| Signal type (voltage) | 24 VDC |
| Output current per channel | 0.1 A |
Digital outputs
| Signal type | Digital |
| Signal type (voltage) | 24 VDC |
Technical data
| Supply voltage (system) | 5 VDC; via data contacts |
| Current consumption (5 V system supply) | 120 mA |
| Supply voltage (field) | 24 VDC, SELV/PELV (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact) |
| Current consumption, field supply (module with no external load) | 35 mA |
| Number of incoming power jumper contacts | 2 |
| Number of outgoing power jumper contacts | 2 |
| Current carrying capacity (power jumper contacts) | 10 A |
Functional Safety
| Achievable safety classes | SIL 3; Category 4, PLe (two-channel); SIL 2; Category 2; PLd (one-channel) |
| Safety standards | IEC 61508-1 … -7; EN ISO 13849-1; EN 62061 |
| Interface types according to ZVEI (inputs) | Drain; A, C0, C1, C2, C3 |
Connection data
| Connection technology: I/O | 16 x CAGE CLAMP® |
| Connectable conductor materials | Copper |
| Connection type | Inputs/outputs |
| Solid conductor | 0.08 … 2.5 mm² / 28 … 14 AWG |
| Fine-stranded conductor | 0.08 … 2.5 mm² / 28 … 14 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
Physical data
| Width | 24 mm / 0.945 inches |
| Height | 100 mm / 3.937 inches |
| Depth | 67.8 mm / 2.669 inches |
| Depth from upper-edge of DIN-rail | 60.6 mm / 2.386 inches |
Mechanical data
| Mounting type | DIN-35 rail |
| Pluggable connector | fixed |
Material data
| Housing material | Polycarbonate; polyamide 6.6 |
| Fire load | 1.91 MJ |
| Weight | 96.5 g |
| Conformity marking | CE |
Environmental requirements
| Ambient temperature (operation) | 0 … +55 °C |
| Ambient temperature (storage) | -25 … +85 °C |
| Protection type | IP20 |
| Pollution degree | 2 per IEC 61131-2 |
| Operating altitude | 0 … 2000 m / 0 … 6562 ft |
| Mounting position | Horizontal left, horizontal right, horizontal top, vertical top and vertical bottom |
| Relative humidity (without condensation) | 95 % |
| Vibration resistance | 4g per IEC 60068-2-6 |
| Shock resistance | 15g per IEC 60068-2-27 |
| EMC immunity to interference | per EN 61000-6-2, marine applications, EN 61000-6-7 (FS) |
| EMC emission of interference | per EN 61000-6-3, -4; marine applications |
| Exposure to pollutants | per IEC 60068-2-42 and IEC 60068-2-43 |
| Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 % | 10 ppm |
| Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 % | 25 ppm |
Commercial data
| PU (SPU) | 1 pcs |
| Packaging type | Box |
| Country of origin | DE |
| GTIN | 4066966334081 |
| Customs tariff number | 85389099990 |
Product Classification
| UNSPSC | 32151705 |
| ETIM 9.0 | EC001599 |
| ETIM 10.0 | EC001599 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 1303-86-2, 1317-36-8, 693-98-1, 7439-92-1, 80-05-7 |
| REACH Candidate List Substance | 2-methylimidazole, 4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | bffe983b-203b-4112-84e6-89e6790923df |
| SCIP notification number (Belgium) | fdf24570-a7d3-4cfe-909a-6340d695de4e |
| SCIP notification number (Bulgaria) | 89eb339d-4807-4740-a943-6999d5b1e756 |
| SCIP notification number (Czech Republic) | 3e8c52cc-5320-4926-b0f5-a5c03799aa8e |
| SCIP notification number (Denmark) | da2def3e-6cf0-4229-9ec7-4e2ae2d0c9fd |
| SCIP notification number (Finland) | 1bf63bc6-2177-4275-8258-3fe7591fc421 |
| SCIP notification number (France) | 98cdfc68-e272-46e0-bcc1-b64e15222c92 |
| SCIP notification number (Germany) | d34568be-ca53-43a8-86e5-30be56a7996b |
| SCIP notification number (Hungary) | a835e7ac-30d8-4889-9d51-5234343a99f1 |
| SCIP notification number (Italy) | 8589371e-4c86-48b8-be1e-0276fd86a30b |
| SCIP notification number (Netherlands) | b7519976-8bca-4637-89f1-c624a9df6bc2 |
| SCIP notification number (Poland) | 7d23aca3-e1a6-4509-9585-0eb1edb3383e |
| SCIP notification number (Romania) | 92f18abe-83da-473a-894c-6aa43f726690 |
| SCIP notification number (Sweden) | e5c053d8-6388-49a0-ba09-a08cd3057cbe |