Pepperl Fuchs VBA-4E4A-G20-ZEJ/M48L-P12
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VBA-4E4A-G20-ZEJ/M48L-P12 be shipped?
VBA-4E4A-G20-ZEJ/M48L-P12 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBA-4E4A-G20-ZEJ/M48L-P12 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBA-4E4A-G20-ZEJ/M48L-P12 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E4A-G20-ZEJ/M48L-P12, subject to availability and destination.
ASi Motor Roller Module. G20 MDR module with AS-Interface for 4 digital inputs and 2 connections for MDRs (48 V). Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: ≥ V3.0. Profile: S-7.A.7. IO code7ID codeAID1 code7ID2 code7: . IO code: 7. ID code: A. ID1 code: 7. ID2 code: 7. UL File Number: E223772 "For use in NFPA 79 Applications only". MTBF: 98 a. Compatible roller motors: Interroll EC5000 48 V AI (20 W / 35 W / 50 W) MTA MRD50 (A interface, 48 V to 44 W). LED FAULT: error display; LED redred: communication error or address is 0red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing. LED ERR: Motor fault: 2 LED yellow. LED PWR: AS-Interface voltage; green LEDgreen: voltage OKgreen flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing. LED AUX: ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage. LED IN: switching state (input); 2 LED yellow. LED FUSE: Motor power supply; 2 green LEDs. LED DIR: Motor rotation direction; yellow LED. LED MOT: Motor active; 2 yellow LEDs. Auxiliary voltage (output): 36 ... 56 V DC PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 25 mA (without sensors) / max. 170 mA. Number/Type: 2 Inputs for 3-wire sensors (PNP), DC. Supply: from AS-Interface. Current loading capacity: 100 mA , overload and short-circuit protected. Input current: ≤ 6 mA (internally limited). Switching point: according to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA1 (damped) ≥ 2.0 mA. Signal delay: < 1 ms (input/AS-Interface). Input filter: 2 ms. Number/Type: 2 outputs for DC roller motors (MOT1, MOT2). Supply: from external auxiliary voltage UAUX. Current: 3.5 A continuous current , 5 A (<2 s) , max. 7.5 A (<0,3 s) per motor. Overload protection: Fuse 4 A, I2t = 122.5 A2s per motor. Velocity signal: 0 ... 10 V DC Control via parameter P1:0. Rotation direction signal: PNP digital output low: high impedancehigh: ≥ 15 V. Motor fault: NPN digital input 0 (no error) ≥ 125 µA 1 (error) ≤ 25 µA. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013+A1:2019: . Directive 2014/30/EU: EN 62026-2:2013+A1:2019. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2:2007. Emitted interference: EN 61000-6-4:2007 , EN 55011:2016+A1:2017+A11:2020. AS-Interface: EN 62026-2:2013+A1:2019. Noise immunity: EN 61000-6-2:2019 , EN 61326-1:2021 , EN 62026-2:2013+A1:2019. Ambient temperature: -25 ... 65 °C (-13 ... 149 °F). Storage temperature: -30 ... 85 °C (-22 ... 185 °F). Relative humidity: 85 % non-condensing. Climatic conditions: For indoor use only. Altitude: ≤ 5000 m above MSL. Shock and impact resistance: 30 g, 11 ms in 6 spatial directions, 3 shocks. Vibration resistance: 0.35 mm / 2 g 10 ... 1000 Hz. Pollution degree: 2. Degree of protection: IP54 according to EN 60529. Connection: AS-Interface, AUX: Insulation piercing technologyYellow flat cable/black flat cableInputs/outputs: M8 round plug connector in accordance with EN 61076-2-104Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)Matching connector: LM004-Gx1-A or similarOutputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded).Matching connector: NM005-Sx1-B or similar. Mass: 310 g. Dimensions: . Height27.5 mmWidth131.5 mmLength54 mm: . Height: 27.5 mm. Width: 131.5 mm. Length: 54 mm. Mounting: 2 clips with ∅ 8 mm drill hole. Cable length: 1 m. Note: The flat cable routing is designed for 100 actuation cycles
Specifications
General specifications
| Node type | A/B node |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V3.0 |
| Profile | S-7.A.7 |
| IO code7ID codeAID1 code7ID2 code7 | IO code |
| IO code | 7 |
| ID code | A |
| ID1 code | 7 |
| ID2 code | 7 |
| UL File Number | E223772 "For use in NFPA 79 Applications only" |
| MTBF | 98 a |
| Compatible roller motors | Interroll EC5000 48 V AI (20 W / 35 W / 50 W) MTA MRD50 (A interface, 48 V to 44 W) |
Indicators/operating means
| LED FAULT | error display; LED redred: communication error or address is 0red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing |
| LED ERR | Motor fault: 2 LED yellow |
| LED PWR | AS-Interface voltage; green LEDgreen: voltage OKgreen flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage |
| LED IN | switching state (input); 2 LED yellow |
| LED FUSE | Motor power supply; 2 green LEDs |
| LED DIR | Motor rotation direction; yellow LED |
| LED MOT | Motor active; 2 yellow LEDs |
Electrical specifications
| Auxiliary voltage (output) | 36 ... 56 V DC PELV UAUX |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 25 mA (without sensors) / max. 170 mA Ie |
Input
| Number/Type | 2 Inputs for 3-wire sensors (PNP), DC |
| Supply | from AS-Interface |
| Current loading capacity | 100 mA , overload and short-circuit protected |
| Input current | ≤ 6 mA (internally limited) |
| Switching point | according to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA1 (damped) ≥ 2.0 mA |
| Signal delay | < 1 ms (input/AS-Interface) |
| Input filter | 2 ms |
Output
| Number/Type | 2 outputs for DC roller motors (MOT1, MOT2) |
| Supply | from external auxiliary voltage UAUX |
| Current | 3.5 A continuous current , 5 A (<2 s) , max. 7.5 A (<0,3 s) per motor |
| Overload protection | Fuse 4 A, I2t = 122.5 A2s per motor |
| Velocity signal | 0 ... 10 V DC Control via parameter P1:0 US |
| Rotation direction signal | PNP digital output low: high impedancehigh: ≥ 15 V UD |
| Motor fault | NPN digital input 0 (no error) ≥ 125 µA 1 (error) ≤ 25 µA |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013+A1:2019 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013+A1:2019 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2:2007 |
| Emitted interference | EN 61000-6-4:2007 , EN 55011:2016+A1:2017+A11:2020 |
| AS-Interface | EN 62026-2:2013+A1:2019 |
| Noise immunity | EN 61000-6-2:2019 , EN 61326-1:2021 , EN 62026-2:2013+A1:2019 |
Ambient conditions
| Ambient temperature | -25 ... 65 °C (-13 ... 149 °F) |
| Storage temperature | -30 ... 85 °C (-22 ... 185 °F) |
| Relative humidity | 85 % non-condensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 5000 m above MSL |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks |
| Vibration resistance | 0.35 mm / 2 g 10 ... 1000 Hz |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP54 according to EN 60529 |
| Connection | AS-Interface, AUX: Insulation piercing technologyYellow flat cable/black flat cableInputs/outputs: M8 round plug connector in accordance with EN 61076-2-104Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)Matching connector: LM004-Gx1-A or similarOutputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded).Matching connector: NM005-Sx1-B or similar |
| Mass | 310 g |
| Dimensions | |
| Height27.5 mmWidth131.5 mmLength54 mm | Height |
| Height | 27.5 mm |
| Width | 131.5 mm |
| Length | 54 mm |
| Mounting | 2 clips with ∅ 8 mm drill hole |
| Cable length | 1 m |
| Note | The flat cable routing is designed for 100 actuation cycles |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs VBA-4E4A-G12-ZEJ/EA2L
Available on requestPepperl Fuchs VBA-4E4A-G2-ZA/EA2
Available on requestPepperl Fuchs VBA-4E4A-G20-ZEJ/M3L-P10
Available on requestPepperl Fuchs VBA-4E4A-G20-ZEJ/M3L-P9
Available on requestPepperl Fuchs VBA-4E4A-KE-ZEJQ/E2L
Available on requestPepperl Fuchs VBA-4E4A-KE-ZE/R
Available on requestPepperl Fuchs VBA-4E4A-KE1-Z/E2
Available on requestPepperl Fuchs VBA-4E4A-KE5-ZEJQ/E2L