Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VBA-4E3A-KE-ZE/R be shipped?
VBA-4E3A-KE-ZE/R is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBA-4E3A-KE-ZE/R in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBA-4E3A-KE-ZE/R and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E3A-KE-ZE/R, subject to availability and destination.
AS-Interface sensor/actuator module. KE switch cabinet module, 4 inputs (PNP) and 3 relay outputs. Node type: A/B node. AS-Interface specification: V2.1. Required gateway specification: ≥ V2.1. Profile: S-7.A.0. IO code7ID codeAID1 code7ID2 code0: . IO code: 7. ID code: A. ID1 code: 7. ID2 code: 0. UL File Number: E106378. LED FAULT: Fault display; Red LEDred: Communication fault or address is 0red, flashing: Overload, internal input supply. LED INT: Internal input supply active; LED green. LED PWR: AS-Interface voltage; LED green. LED IN: switching state (input); 4 LED yellow. LED OUT: Switching state (output); 3 LED yellow. Auxiliary voltage (input): 12 ... 30 V DC PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 35 mA (without sensors) / max. 235 mA. Surge protection: O1 ... O3: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT). Voltage: 21 ... 31 V DC (INT). Current loading capacity: ≤ 150 mA, overload- and short-circuit protected (INT). Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Signal delay: < 2 ms (input/AS-Interface). Signal frequency: ≤ 250 Hz. Number/Type: 3 relay outputs, normally open. Supply: none. Nominal load: . Per contactmax. 2 A / 30 V DC; 2 A / 250 V ACPer module6 A: . Per contact: max. 2 A / 30 V DC; 2 A / 250 V AC. Per module: 6 A. Minimum load: . Per contact10 mA / 5 V DC: . Per contact: 10 mA / 5 V DC. Short-circuit-proof: Contact: 500 A / 40 ms. Switching off power: 500 VA. Switching delay: < 10 ms (AS-Interface/contact). Usage category: DC-13 and AC-14. Switching frequency: < 20 Hz (without load)< 0.1 Hz (nominal load). Switching: . Mechanical30 x 106Electrical1 x 106 switching cycles (40 V DC, 2 A, ohmic)0.5 x 106 switching cycles (253 V AC, 2 A, cos φ = 1)0.45 x 106 switching cycles (253 V AC, 2 A, cos φ = 0.7): . Mechanical: 30 x 106. Electrical: 1 x 106 switching cycles (40 V DC, 2 A, ohmic)0.5 x 106 switching cycles (253 V AC, 2 A, cos φ = 1)0.45 x 106 switching cycles (253 V AC, 2 A, cos φ = 0.7). Input/Output: IN1 ... IN4 to O1 ... O3: safe isolation acc. to EN 60947-1,rated insulation voltage 278 V AC. Input/AS-Interface: none. Output/Output: O1 to O2, O3: safe isolation according to EN 60947-1,rated insulation voltage 278 V ACO2 to O3: basic insulation according to EN 60947-1,rated insulation voltage 278 V AC. Output/AS-Interface: safe isolation acc. to EN 60947-1,rated insulation voltage 278 V AC. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007. Low voltage: . Directive 73/23/EECEN 60947-1:2007: . Directive 73/23/EEC: EN 60947-1:2007. Galvanic isolation: EN 60947-1. Electromagnetic compatibility: NAMUR NE 21: 1998-08. Degree of protection: EN 60529:2000. Pollution degree: EN 60947-5-1. Input: EN 61131-2:2004. Usage category: EN 60947-5-1. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 2. Degree of protection: IP20. Connection: removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2. Material: . HousingPA 66-FR: . Housing: PA 66-FR. Mass: 170 g. Dimensions: . Height99 mmWidth22.5 mmLength102 mm: . Height: 99 mm. Width: 22.5 mm. Length: 102 mm. Mounting: DIN mounting rail. Tightening torque of clamping screws: 0.5 Nm ... 0.6 Nm
Specifications
General specifications
| Node type | A/B node |
| AS-Interface specification | V2.1 |
| Required gateway specification | ≥ V2.1 |
| Profile | S-7.A.0 |
| IO code7ID codeAID1 code7ID2 code0 | IO code |
| IO code | 7 |
| ID code | A |
| ID1 code | 7 |
| ID2 code | 0 |
| UL File Number | E106378 |
Indicators/operating means
| LED FAULT | Fault display; Red LEDred: Communication fault or address is 0red, flashing: Overload, internal input supply |
| LED INT | Internal input supply active; LED green |
| LED PWR | AS-Interface voltage; LED green |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | Switching state (output); 3 LED yellow |
Electrical specifications
| Auxiliary voltage (input) | 12 ... 30 V DC PELV UEXT |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 35 mA (without sensors) / max. 235 mA Ie |
| Surge protection | O1 ... O3: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
| Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
| Voltage | 21 ... 31 V DC (INT) |
| Current loading capacity | ≤ 150 mA, overload- and short-circuit protected (INT) |
| Input current | ≤ 8 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA | 0 (unattenuated) |
| 0 (unattenuated) | ≤ 2 mA |
| 1 (attenuated) | ≥ 4 mA |
| Signal delay | < 2 ms (input/AS-Interface) |
| Signal frequency | ≤ 250 Hz |
Output
| Number/Type | 3 relay outputs, normally open |
| Supply | none |
| Nominal load | |
| Per contactmax. 2 A / 30 V DC; 2 A / 250 V ACPer module6 A | Per contact |
| Per contact | max. 2 A / 30 V DC; 2 A / 250 V AC |
| Per module | 6 A |
| Minimum load | |
| Per contact10 mA / 5 V DC | Per contact |
| Per contact | 10 mA / 5 V DC |
| Short-circuit-proof | Contact: 500 A / 40 ms |
| Switching off power | 500 VA |
| Switching delay | < 10 ms (AS-Interface/contact) |
| Usage category | DC-13 and AC-14 |
| Switching frequency | < 20 Hz (without load)< 0.1 Hz (nominal load) f |
| Switching | |
| Mechanical30 x 106Electrical1 x 106 switching cycles (40 V DC, 2 A, ohmic)0.5 x 106 switching cycles (253 V AC, 2 A, cos φ = 1)0.45 x 106 switching cycles (253 V AC, 2 A, cos φ = 0.7) | Mechanical |
| Mechanical | 30 x 106 |
| Electrical | 1 x 106 switching cycles (40 V DC, 2 A, ohmic)0.5 x 106 switching cycles (253 V AC, 2 A, cos φ = 1)0.45 x 106 switching cycles (253 V AC, 2 A, cos φ = 0.7) |
Galvanic isolation
| Input/Output | IN1 ... IN4 to O1 ... O3: safe isolation acc. to EN 60947-1,rated insulation voltage 278 V AC |
| Input/AS-Interface | none |
| Output/Output | O1 to O2, O3: safe isolation according to EN 60947-1,rated insulation voltage 278 V ACO2 to O3: basic insulation according to EN 60947-1,rated insulation voltage 278 V AC |
| Output/AS-Interface | safe isolation acc. to EN 60947-1,rated insulation voltage 278 V AC |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 |
| Low voltage | |
| Directive 73/23/EECEN 60947-1:2007 | Directive 73/23/EEC |
| Directive 73/23/EEC | EN 60947-1:2007 |
Standard conformity
| Galvanic isolation | EN 60947-1 |
| Electromagnetic compatibility | NAMUR NE 21: 1998-08 |
| Degree of protection | EN 60529:2000 |
| Pollution degree | EN 60947-5-1 |
| Input | EN 61131-2:2004 |
| Usage category | EN 60947-5-1 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005 |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 |
| Material | |
| HousingPA 66-FR | Housing |
| Housing | PA 66-FR |
| Mass | 170 g |
| Dimensions | |
| Height99 mmWidth22.5 mmLength102 mm | Height |
| Height | 99 mm |
| Width | 22.5 mm |
| Length | 102 mm |
| Mounting | DIN mounting rail |
| Tightening torque of clamping screws | 0.5 Nm ... 0.6 Nm |