Pepperl Fuchs VBA-4E3A-G20-ZEL/M1L-P2
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VBA-4E3A-G20-ZEL/M1L-P2 be shipped?
VBA-4E3A-G20-ZEL/M1L-P2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBA-4E3A-G20-ZEL/M1L-P2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBA-4E3A-G20-ZEL/M1L-P2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E3A-G20-ZEL/M1L-P2, subject to availability and destination.
ASi Motor Roller Module. G20 MDR module with AS-Interface for 4 digital inputs and 2 connections for MDRs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.1. Profile: S-7.A.E. IO code7ID codeAID1 code6ID2 codeE: . IO code: 7. ID code: A. ID1 code: 6. ID2 code: E. UL File Number: E223772 "For use in NFPA 79 Applications only". MTBF: 98 a. Compatible roller motors: Interroll EC310 Interroll EC5000 24 V AI (20 W / 35 W / 50 W) Rulmeca BL3 Itoh Denki PM500XK Itoh Denki PM500XC PULSEROLLER Senergy-IDC MTA MRD50 (A interface, 24 V to 40 W) WWL R-*-H + CE23XX Conveline RM50. LED yellow/red: . LED FAULT: error display; LED redred: communication error or address is 0red flashing: overload of sensor supply or external auxiliary voltage UAUX missing. LED ERR: Motor fault: 2 LED yellow. LED PWR: AS-Interface voltage; green LEDgreen: voltage OKgreen flashing: address 0 or sensor supply overload or external auxiliary voltage UAUX missing. LED AUX: ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage. LED IN: switching state (input); 2 LED yellow. LED FUSE: Motor power supply; 2 green LEDs. LED DIR: Motor rotation direction; yellow LED. LED MOT: Motor active; 2 yellow LEDs. Auxiliary voltage (output): 18 ... 30 VDC PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 35 mA. Number/Type: 2 Inputs for 3-wire sensors (PNP), DC. Supply: from external auxiliary voltage UAUX. Current loading capacity: 500 mA , overload and short-circuit protected. Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA1 (damped) ≥ 2.0 mA. Signal delay: < 1 ms (input/AS-Interface). Input filter: 2 ms. Number/Type: 2 outputs for DC roller motors (MOT1, MOT2). Supply: from external auxiliary voltage UAUX. Current: 3.5 A continuous current , 5 A (<2 s) , max. 7.5 A (<0,3 s) per motor. Overload protection: Fuse 5 A, I2t = 53.7 A2s per motor. Velocity signal: 1.4 … 13 V at no-load Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ Control via parameter P2:0. Rotation direction signal: Off / ≥ (UAUX - 1.0 V) at no-load Ri = 5.6 kΩ, RLOAD ≥ 5 kΩ AS-Interface data bit D2 = 0: UD = Off. Motor fault: Digital input NPN, U0 = 3.3 V, Ri = 52 kΩ 0 (no error) ≥ 40 µA 1 (error) ≤ 30 µA. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013: . Directive 2014/30/EU: EN 62026-2:2013. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2:2007. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -30 ... 85 °C (-22 ... 185 °F). Degree of protection: IP54 according to EN 60529. Connection: AS-Interface, AUX: Insulation piercing technologyYellow flat cable/black flat cableInputs/outputs: M8 round plug connector in accordance with EN 61076-2-104Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)Matching connector: LM004-Gx1-A or similarOutputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded).Matching connector: NM005-Sx1-B or similar. Mass: 220 g. Dimensions: . Height27.5 mmWidth131.5 mmLength54 mm: . Height: 27.5 mm. Width: 131.5 mm. Length: 54 mm. Mounting: 2 clips with ∅ 8 mm drill hole. Cable length: 1 m. Note: The flat cable routing is designed for 100 actuation cycles
Specifications
General specifications
| Node type | A/B node |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V2.1 |
| Profile | S-7.A.E |
| IO code7ID codeAID1 code6ID2 codeE | IO code |
| IO code | 7 |
| ID code | A |
| ID1 code | 6 |
| ID2 code | E |
| UL File Number | E223772 "For use in NFPA 79 Applications only" |
| MTBF | 98 a |
| Compatible roller motors | Interroll EC310 Interroll EC5000 24 V AI (20 W / 35 W / 50 W) Rulmeca BL3 Itoh Denki PM500XK Itoh Denki PM500XC PULSEROLLER Senergy-IDC MTA MRD50 (A interface, 24 V to 40 W) WWL R-*-H + CE23XX Conveline RM50 |
Indicators/operating means
| LED yellow/red | |
| LED FAULT | error display; LED redred: communication error or address is 0red flashing: overload of sensor supply or external auxiliary voltage UAUX missing |
| LED ERR | Motor fault: 2 LED yellow |
| LED PWR | AS-Interface voltage; green LEDgreen: voltage OKgreen flashing: address 0 or sensor supply overload or external auxiliary voltage UAUX missing |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage |
| LED IN | switching state (input); 2 LED yellow |
| LED FUSE | Motor power supply; 2 green LEDs |
| LED DIR | Motor rotation direction; yellow LED |
| LED MOT | Motor active; 2 yellow LEDs |
Electrical specifications
| Auxiliary voltage (output) | 18 ... 30 VDC PELV UAUX |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 35 mA Ie |
Input
| Number/Type | 2 Inputs for 3-wire sensors (PNP), DC |
| Supply | from external auxiliary voltage UAUX |
| Current loading capacity | 500 mA , overload and short-circuit protected |
| Input current | ≤ 8 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA1 (damped) ≥ 2.0 mA |
| Signal delay | < 1 ms (input/AS-Interface) |
| Input filter | 2 ms |
Output
| Number/Type | 2 outputs for DC roller motors (MOT1, MOT2) |
| Supply | from external auxiliary voltage UAUX |
| Current | 3.5 A continuous current , 5 A (<2 s) , max. 7.5 A (<0,3 s) per motor |
| Overload protection | Fuse 5 A, I2t = 53.7 A2s per motor |
| Velocity signal | 1.4 … 13 V at no-load Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ Control via parameter P2:0 US |
| Rotation direction signal | Off / ≥ (UAUX - 1.0 V) at no-load Ri = 5.6 kΩ, RLOAD ≥ 5 kΩ AS-Interface data bit D2 = 0: UD = Off UD |
| Motor fault | Digital input NPN, U0 = 3.3 V, Ri = 52 kΩ 0 (no error) ≥ 40 µA 1 (error) ≤ 30 µA |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2:2007 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -30 ... 85 °C (-22 ... 185 °F) |
Mechanical specifications
| Degree of protection | IP54 according to EN 60529 |
| Connection | AS-Interface, AUX: Insulation piercing technologyYellow flat cable/black flat cableInputs/outputs: M8 round plug connector in accordance with EN 61076-2-104Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)Matching connector: LM004-Gx1-A or similarOutputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded).Matching connector: NM005-Sx1-B or similar |
| Mass | 220 g |
| Dimensions | |
| Height27.5 mmWidth131.5 mmLength54 mm | Height |
| Height | 27.5 mm |
| Width | 131.5 mm |
| Length | 54 mm |
| Mounting | 2 clips with ∅ 8 mm drill hole |
| Cable length | 1 m |
| Note | The flat cable routing is designed for 100 actuation cycles |