Pepperl Fuchs VBA-2E2A-G4-ZE/E2
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VBA-2E2A-G4-ZE/E2 be shipped?
VBA-2E2A-G4-ZE/E2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBA-2E2A-G4-ZE/E2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBA-2E2A-G4-ZE/E2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-2E2A-G4-ZE/E2, subject to availability and destination.
AS-Interface sensor/actuator module. G4 module IP67, 2 inputs (PNP) and 2 electronic outputs. Node type: A/B node. AS-Interface specification: V2.1. Required gateway specification: ≥ V2.1. UL File Number: E223772. LED PWR/FAULT: dual LED green/redgreen: AS-Interface voltagered: communication error or address 0green/red flashing: overload sensor supply or outputs. LED IN: switching state (input); 2 LED yellow. LED OUT: Switching state (output); 2 LED yellow. Auxiliary voltage (output): 24 V DC ± 15 % PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 30 mA (without sensors) / max. 140 mA. Protection class: III. Surge protection: UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 2 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface. Voltage: 21 ... 31 V. Current loading capacity: ≤ 100 mA (TB ≤ 40 °C),≤ 75 mA (TB ≤ 60 °C), overload-proof and short-circuit protected. Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Number/Type: 2 electronic outputs, PNP overload and short-circuit proof. Supply: from external auxiliary voltage UAUX. Voltage: ≥ (UAUX - 0.5 V). Current: 1 A per output. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001. Degree of protection: EN 60529:2000. Input: EN 61131-2:2007. Emitted interference: EN 61000-6-4:2001. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2001. Profile: S-B.A.0. IO code: B. ID code: A. ID1 code: 7. ID2 code: 0. Data bits (function via AS-Interface): InputOutput. D0 - OUT1D1 - OUT2D2 IN3 -D3 IN4 -: . D0: - OUT1. D1: - OUT2. D2: IN3 -. D3: IN4 -. Parameter bits (programmable via AS-i): function. P0not usedP1not usedP2not usedP3not used: . P0: not used. P1: not used. P2: not used. P3: not used. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 3. Degree of protection: IP67. Connection: cable piercing method or terminal compartmentyellow flat cable/black flat cable or standard round cableinputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals. Material: . HousingPA 6 GF30: . Housing: PA 6 GF30. Mass: 180 g. Tightening torque, housing screws: 0.8 Nm. Dimensions: . Height51 mmWidth45 mmLength102 mm: . Height: 51 mm. Width: 45 mm. Length: 102 mm. Mounting: DIN rail or screw mounting
Specifications
General specifications
| Node type | A/B node |
| AS-Interface specification | V2.1 |
| Required gateway specification | ≥ V2.1 |
| UL File Number | E223772 |
Indicators/operating means
| LED PWR/FAULT | dual LED green/redgreen: AS-Interface voltagered: communication error or address 0green/red flashing: overload sensor supply or outputs |
| LED IN | switching state (input); 2 LED yellow |
| LED OUT | Switching state (output); 2 LED yellow |
Electrical specifications
| Auxiliary voltage (output) | 24 V DC ± 15 % PELV UAUX |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 30 mA (without sensors) / max. 140 mA Ie |
| Protection class | III |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 2 inputs for 2- or 3-wire sensors (PNP), DC |
| Supply | from AS-Interface |
| Voltage | 21 ... 31 V |
| Current loading capacity | ≤ 100 mA (TB ≤ 40 °C),≤ 75 mA (TB ≤ 60 °C), overload-proof and short-circuit protected |
| Input current | ≤ 8 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA | 0 (unattenuated) |
| 0 (unattenuated) | ≤ 2 mA |
| 1 (attenuated) | ≥ 4 mA |
Output
| Number/Type | 2 electronic outputs, PNP overload and short-circuit proof |
| Supply | from external auxiliary voltage UAUX |
| Voltage | ≥ (UAUX - 0.5 V) |
| Current | 1 A per output |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Input | EN 61131-2:2007 |
| Emitted interference | EN 61000-6-4:2001 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2001 |
Programming instructions
| Profile | S-B.A.0 |
| IO code | B |
| ID code | A |
| ID1 code | 7 |
| ID2 code | 0 |
| Data bits (function via AS-Interface) | InputOutput |
| D0 - OUT1D1 - OUT2D2 IN3 -D3 IN4 - | D0 |
| D0 | - OUT1 |
| D1 | - OUT2 |
| D2 | IN3 - |
| D3 | IN4 - |
| Parameter bits (programmable via AS-i) | function |
| P0not usedP1not usedP2not usedP3not used | P0 |
| P0 | not used |
| P1 | not used |
| P2 | not used |
| P3 | not used |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 3 |
Mechanical specifications
| Degree of protection | IP67 |
| Connection | cable piercing method or terminal compartmentyellow flat cable/black flat cable or standard round cableinputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals |
| Material | |
| HousingPA 6 GF30 | Housing |
| Housing | PA 6 GF30 |
| Mass | 180 g |
| Tightening torque, housing screws | 0.8 Nm |
| Dimensions | |
| Height51 mmWidth45 mmLength102 mm | Height |
| Height | 51 mm |
| Width | 45 mm |
| Length | 102 mm |
| Mounting | DIN rail or screw mounting |