Available on request

Pepperl Fuchs VBA-2E2A-G2-ZEJ/XE2J

MPN: VBA-2E2A-G2-ZEJ/XE2J · Brand: Pepperl Fuchs
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryModules
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can VBA-2E2A-G2-ZEJ/XE2J be shipped?

VBA-2E2A-G2-ZEJ/XE2J is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up VBA-2E2A-G2-ZEJ/XE2J in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for VBA-2E2A-G2-ZEJ/XE2J and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-2E2A-G2-ZEJ/XE2J, subject to availability and destination.

AS-Interface sensor/actuator module. G2 flat module, 2 inputs (PNP) and 2 electronic outputs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.1. UL File Number: E223772. LED FAULT: error display; LED redred: communication error or address is 0red flashing: overload of sensor power supply or outputs. LED PWR: AS-Interface voltage; LED green. LED IN: switching state (input); 2 LED yellow. LED OUT: Switching state (output); 2 LED yellow. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 40 mA (without sensors) / max. 170 mA. Protection class: III. Surge protection: Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 2 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface. Voltage: 21 ... 31 V. Current loading capacity: ≤ 130 mA (TB ≤ 40 °C),≤ 100 mA (TB ≤ 60 °C), overload and short-circuit protected. Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Number/Type: 2 electronic outputs, PNP overload and short-circuit proof. Supply: from AS-Interface. Current: limited by the current loading capacity of the module. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001. Degree of protection: EN 60529:2000. Input: EN 61131-2:2007. Emitted interference: EN 61000-6-4:2001. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2001. Profile: S-B.A.E. IO code: B. ID code: A. ID1 code: 7. ID2 code: E. Data bits (function via AS-Interface): InputOutput. D0 - OUT1D1 - OUT2D2 IN3 -D3 IN4 -: . D0: - OUT1. D1: - OUT2. D2: IN3 -. D3: IN4 -. Parameter bits (programmable via AS-i): function. P0not usedP1not usedP2not usedP3not used: . P0: not used. P1: not used. P2: not used. P3: not used. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 3. Degree of protection: IP67. Connection: cable piercing method: flat cable yellowinputs/outputs: M12 round connector. Material: . HousingPBT: . Housing: PBT. Mass: 100 g. Tightening torque, cable gland: 0.4 Nm. Mounting: Mounting plate

Specifications

General specifications

Node typeA/B node
AS-Interface specificationV3.0
Required gateway specification≥ V2.1
UL File NumberE223772

Indicators/operating means

LED FAULTerror display; LED redred: communication error or address is 0red flashing: overload of sensor power supply or outputs
LED PWRAS-Interface voltage; LED green
LED INswitching state (input); 2 LED yellow
LED OUTSwitching state (output); 2 LED yellow

Electrical specifications

Rated operating voltage26.5 ... 31.6 V from AS-Interface Ue
Rated operating current≤ 40 mA (without sensors) / max. 170 mA Ie
Protection classIII
Surge protectionUe: Over voltage category III, safe isolated power supplies (PELV)

Input

Number/Type2 inputs for 2- or 3-wire sensors (PNP), DC
Supplyfrom AS-Interface
Voltage21 ... 31 V
Current loading capacity≤ 130 mA (TB ≤ 40 °C),≤ 100 mA (TB ≤ 60 °C), overload and short-circuit protected
Input current≤ 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA 0 (unattenuated)
0 (unattenuated)≤ 2 mA
1 (attenuated)≥ 4 mA

Output

Number/Type2 electronic outputs, PNP overload and short-circuit proof
Supplyfrom AS-Interface
Currentlimited by the current loading capacity of the module

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 Directive 2014/30/EU
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001

Standard conformity

Degree of protectionEN 60529:2000
InputEN 61131-2:2007
Emitted interferenceEN 61000-6-4:2001
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2001

Programming instructions

ProfileS-B.A.E
IO codeB
ID codeA
ID1 code7
ID2 codeE
Data bits (function via AS-Interface)InputOutput
D0 - OUT1D1 - OUT2D2 IN3 -D3 IN4 - D0
D0- OUT1
D1- OUT2
D2IN3 -
D3IN4 -
Parameter bits (programmable via AS-i)function
P0not usedP1not usedP2not usedP3not used P0
P0not used
P1not used
P2not used
P3not used

Ambient conditions

Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , noncondensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Pollution degree3

Mechanical specifications

Degree of protectionIP67
Connectioncable piercing method: flat cable yellowinputs/outputs: M12 round connector
Material
HousingPBT Housing
HousingPBT
Mass100 g
Tightening torque, cable gland0.4 Nm
MountingMounting plate
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote