Quick facts

AvailabilityConfirmed on request
CategoryInductive Positioning Systems
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can PMI14V-F166-U be shipped?

PMI14V-F166-U is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up PMI14V-F166-U in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for PMI14V-F166-U and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PMI14V-F166-U, subject to availability and destination.

Inductive positioning system. Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scalable measuring range programmable via cable, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, UL approval: cULus Listed <BR>Load Type: General Purpose <BR>Circuitry: Class 2 Power Source <BR>Enclosure Type Rating: Type 1 <BR>Supply/Switching Voltage: 30 V DC. Switching element function: Analog voltage output. Object distance: 0.5 ... 2 mm. Measuring range: 0 ... 14 mm. Operating voltage: 18 ... 30 V DC. Reverse polarity protection: reverse polarity protected. Linearity error: ± 0.3 mm. Repeat accuracy: ± 0.05 mm. Resolution: 33 µm. Temperature drift: ± 0.3 mm (With a target distance of 0.5 mm). No-load supply current: ≤ 20 mA. MTTFd: 830 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Output type: 1 voltage output: 0 ... 10 V. Load resistor: ≥ 1000 Ω. Short-circuit protection: current limit. Standard conformity: . StandardsEN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003: . Standards: EN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC. Ambient temperature: -10 ... 70 °C (14 ... 158 °F). Storage temperature: -20 ... 70 °C (-4 ... 158 °F). Connection type: 5 x 0.14 mm2 , screened 2 m PUR cable. Degree of protection: IP65. Material: . HousingZinc diecast, nickel-plated cover , PBTTargetmild steel, e. g. 1.0037, SR235JR (formerly St37-2): . Housing: Zinc diecast, nickel-plated cover , PBT. Target: mild steel, e. g. 1.0037, SR235JR (formerly St37-2). Cable: . Cable diameter4.8 mmBending radius> 10 x cable diameter: . Cable diameter: 4.8 mm. Bending radius: > 10 x cable diameter. Mass: 95 g. Dimensions: . Height17.7 mmWidth30 mmLength39 mm: . Height: 17.7 mm. Width: 30 mm. Length: 39 mm

Specifications

General specifications

Switching element functionAnalog voltage output
Object distance0.5 ... 2 mm
Measuring range0 ... 14 mm

Nominal ratings

Operating voltage18 ... 30 V DC UB
Reverse polarity protectionreverse polarity protected
Linearity error± 0.3 mm
Repeat accuracy± 0.05 mm R
Resolution33 µm
Temperature drift± 0.3 mm (With a target distance of 0.5 mm)
No-load supply current≤ 20 mA I0

Functional safety related parameters

MTTFd830 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Analog output

Output type1 voltage output: 0 ... 10 V
Load resistor≥ 1000 Ω
Short-circuit protectioncurrent limit

Compliance with standards and directives

Standard conformity
StandardsEN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003 Standards
StandardsEN 60947-5-2:2007 IEC 60947-5-2:2007 EN 60947-5-7:2003

Approvals and certificates

UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC

Ambient conditions

Ambient temperature-10 ... 70 °C (14 ... 158 °F)
Storage temperature-20 ... 70 °C (-4 ... 158 °F)

Mechanical specifications

Connection type5 x 0.14 mm2 , screened 2 m PUR cable
Degree of protectionIP65
Material
HousingZinc diecast, nickel-plated cover , PBTTargetmild steel, e. g. 1.0037, SR235JR (formerly St37-2) Housing
HousingZinc diecast, nickel-plated cover , PBT
Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Cable
Cable diameter4.8 mmBending radius> 10 x cable diameter Cable diameter
Cable diameter4.8 mm
Bending radius> 10 x cable diameter
Mass95 g
Dimensions
Height17.7 mmWidth30 mmLength39 mm Height
Height17.7 mm
Width30 mm
Length39 mm
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote