Pepperl Fuchs PMI14V-F112-U-IO
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Inductive Positioning Systems |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can PMI14V-F112-U-IO be shipped?
PMI14V-F112-U-IO is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PMI14V-F112-U-IO in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PMI14V-F112-U-IO and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PMI14V-F112-U-IO, subject to availability and destination.
Inductive positioning system. Parameterization and diagnosis via IO-Link, Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Shielded line 2 m, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed
Load Type: General Purpose
Circuitry: Class 2 Power Source
Enclosure Type Rating: Type 1
Supply/Switching Voltage: 30 V DC. Switching element function: Analog voltage output. Installation: flush. Object distance: max. 2.5 mm. Measuring range: 0 ... 14 mm. Operating voltage: 18 ... 30 V DC. Reverse polarity protection: reverse polarity protected. Linearity error: ± 0.3 mm. Repeat accuracy: ± 0.05 mm. Resolution: 33 µm. Temperature drift: ± 0.5 mm. No-load supply current: ≤ 20 mA. Operating voltage indicator: LED green. MTTFd: 490 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Interface type: IO-Link. Mode: COM2 (38.4 kBit/s). Value range: 0000h ... 7000h. Output type: voltage output 0 ... 10 V. Load resistor: ≥ 2000 Ω. Short-circuit protection: limited to 6 mA. Standard conformity: . StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013: . Standards: EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Connection type: 2 m PUR cable , screened. Housing material: diecast zinc, not laquered or coated. Degree of protection: IP67. Material: . Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2): . Target: mild steel, e. g. 1.0037, SR235JR (formerly St37-2). Cable: . Cable diameter4.8 mmBending radius> 10 x cable diameter: . Cable diameter: 4.8 mm. Bending radius: > 10 x cable diameter. Dimensions: . Height30.5 mmWidth35 mmLength35 mm: . Height: 30.5 mm. Width: 35 mm. Length: 35 mm. Note: The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5 mm.
Specifications
General specifications
| Switching element function | Analog voltage output |
| Installation | flush |
| Object distance | max. 2.5 mm |
| Measuring range | 0 ... 14 mm |
Nominal ratings
| Operating voltage | 18 ... 30 V DC UB |
| Reverse polarity protection | reverse polarity protected |
| Linearity error | ± 0.3 mm |
| Repeat accuracy | ± 0.05 mm R |
| Resolution | 33 µm |
| Temperature drift | ± 0.5 mm |
| No-load supply current | ≤ 20 mA I0 |
| Operating voltage indicator | LED green |
Functional safety related parameters
| MTTFd | 490 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Interface
| Interface type | IO-Link |
| Mode | COM2 (38.4 kBit/s) |
| Value range | 0000h ... 7000h |
Analog output
| Output type | voltage output 0 ... 10 V |
| Load resistor | ≥ 2000 Ω |
| Short-circuit protection | limited to 6 mA |
Compliance with standards and directives
| Standard conformity | |
| StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 | Standards |
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 |
Approvals and certificates
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications
| Connection type | 2 m PUR cable , screened |
| Housing material | diecast zinc, not laquered or coated |
| Degree of protection | IP67 |
| Material | |
| Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2) | Target |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
| Cable | |
| Cable diameter4.8 mmBending radius> 10 x cable diameter | Cable diameter |
| Cable diameter | 4.8 mm |
| Bending radius | > 10 x cable diameter |
| Dimensions | |
| Height30.5 mmWidth35 mmLength35 mm | Height |
| Height | 30.5 mm |
| Width | 35 mm |
| Length | 35 mm |
| Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5 mm. |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs PMI14V-F112-2EPE2-IO
Available on requestPepperl Fuchs PMI14V-F112-2EPE2-IO-V15
Available on requestPepperl Fuchs PMI14V-F112-2EPE2-IO-Y70104219
Available on requestPepperl Fuchs PMI14V-F112-U-200MM-V3
Available on requestPepperl Fuchs PMI14V-F112-U-IO-2M-V31
Available on requestPepperl Fuchs PMI14V-F112-U-IO-V31
Available on requestPepperl Fuchs PMI14V-F112-U-V3
Available on requestPepperl Fuchs PMI14V-F166-2E2