Pepperl Fuchs DoorScan Relay Module
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Accessories |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can DoorScan Relay Module be shipped?
DoorScan Relay Module is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up DoorScan Relay Module in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for DoorScan Relay Module and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for DoorScan Relay Module, subject to availability and destination.
Accessory DGE. Sensor module for configurable DoorScan<sup>®</sup> presence sensor, Conversion of semiconductor signals to relay output signals, Tool-free module mounting using snap-in mechanism, Operating voltage: 24 V DC ± 20 %, Signal output: Hinge side (BS): Relay, 1 alternator , Opposite hinge side (BGS): Relay, 1 alternator, Connection: plug strip , 6-pin Interface , 4-pin Relay supply. Safety Integrity Level (SIL): SIL 2. Performance level (PL): PL d. Category: Cat. 2. MTTFd: 72 a. B10d: 2 E+8. B10: 3 E+6. Control elements: Jumper for interface PNP / NPN. Operating voltage: 24 V DC ± 20 %. No-load supply current: 30 mA. Input type: Test, Standby , Relay supply. Signal output: Hinge side (BS): Relay, 1 alternator , Opposite hinge side (BGS): Relay, 1 alternator. Switching voltage: 24 V DC ± 20 %. Switching current: max. 100 mA. Response time: max. 15 ms in addition to switch-on delay for DoorScan®. De-energized delay: max. 15 ms. Directive conformity: . Machinery Directive 2006/42/ECEN 12978:2003+A1:2009 EN ISO 13849-1:2008 + AC:2009 EN 16005:2012 Chapter 4.6.8EMC Directive 2004/108/ECEN 61000-6-2:2005 EN 61000-6-3:2007+A1:2011: . Machinery Directive 2006/42/EC: EN 12978:2003+A1:2009 EN ISO 13849-1:2008 + AC:2009 EN 16005:2012 Chapter 4.6.8. EMC Directive 2004/108/EC: EN 61000-6-2:2005 EN 61000-6-3:2007+A1:2011. Standard conformity: . StandardsEN 61508-1:2010 DIN 18650-1:2010 Chapter 5.7.4 BS 7036-1:1996 Chapter 7.3.2 BS 7036-2:1996 Chapter 8.1: . Standards: EN 61508-1:2010 DIN 18650-1:2010 Chapter 5.7.4 BS 7036-1:1996 Chapter 7.3.2 BS 7036-2:1996 Chapter 8.1. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -30 ... 60 °C (-22 ... 140 °F). Relative humidity: 25 ... 95 % (noncondensing). Degree of protection: IP54 (when mounted). Connection: plug strip , 6-pin Interface , 4-pin Relay supply. Mass: approx. 30 g. Dimensions: . Height30 mmDepth35 mmLength81 mm: . Height: 30 mm. Depth: 35 mm. Length: 81 mm
Specifications
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| Performance level (PL) | PL d |
| Category | Cat. 2 |
| MTTFd | 72 a |
| B10d | 2 E+8 |
| B10 | 3 E+6 |
Indicators/operating means
| Control elements | Jumper for interface PNP / NPN |
Electrical specifications
| Operating voltage | 24 V DC ± 20 % UB |
| No-load supply current | 30 mA I0 |
Input
| Input type | Test, Standby , Relay supply |
Output
| Signal output | Hinge side (BS): Relay, 1 alternator , Opposite hinge side (BGS): Relay, 1 alternator |
| Switching voltage | 24 V DC ± 20 % |
| Switching current | max. 100 mA |
| Response time | max. 15 ms in addition to switch-on delay for DoorScan® |
| De-energized delay | max. 15 ms toff |
Compliance with standards and directives
| Directive conformity | |
| Machinery Directive 2006/42/ECEN 12978:2003+A1:2009 EN ISO 13849-1:2008 + AC:2009 EN 16005:2012 Chapter 4.6.8EMC Directive 2004/108/ECEN 61000-6-2:2005 EN 61000-6-3:2007+A1:2011 | Machinery Directive 2006/42/EC |
| Machinery Directive 2006/42/EC | EN 12978:2003+A1:2009 EN ISO 13849-1:2008 + AC:2009 EN 16005:2012 Chapter 4.6.8 |
| EMC Directive 2004/108/EC | EN 61000-6-2:2005 EN 61000-6-3:2007+A1:2011 |
| Standard conformity | |
| StandardsEN 61508-1:2010 DIN 18650-1:2010 Chapter 5.7.4 BS 7036-1:1996 Chapter 7.3.2 BS 7036-2:1996 Chapter 8.1 | Standards |
| Standards | EN 61508-1:2010 DIN 18650-1:2010 Chapter 5.7.4 BS 7036-1:1996 Chapter 7.3.2 BS 7036-2:1996 Chapter 8.1 |
Approvals and certificates
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -30 ... 60 °C (-22 ... 140 °F) |
| Relative humidity | 25 ... 95 % (noncondensing) |
Mechanical specifications
| Degree of protection | IP54 (when mounted) |
| Connection | plug strip , 6-pin Interface , 4-pin Relay supply |
| Mass | approx. 30 g |
| Dimensions | |
| Height30 mmDepth35 mmLength81 mm | Height |
| Height | 30 mm |
| Depth | 35 mm |
| Length | 81 mm |