Pepperl Fuchs 28 II EX PCEC
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Digital Multimeters |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 28 II EX PCEC be shipped?
28 II EX PCEC is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 28 II EX PCEC in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 28 II EX PCEC and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 28 II EX PCEC, subject to availability and destination.
Intrinsically safe digital multimeter. Rugged and intrinsically safe multimeter. Measuring range: . DC voltage0.1 mV to 1000 VAccuracy: ± (0.05 % + 1)AC voltage0.1 mV to 1000 VAccuracy: ± (0.7 % + 4)DC current0.1 µA to 10 AAccuracy: ± (0.2 % + 4)AC current0.1 µA to 10 AAccuracy: ± (1.0 % + 2)Resistor0.1 Ω to 50 MΩAccuracy: ± (0.2 % + 1)Conductivity60.00 nSAccuracy: ± (1.0 % + 10)Diode test2.0 VAccuracy: ± (2.0 % + 1)Duty cycle0.0 % to 99.9 %Accuracy: Within ± (0.2 % per kHz + 0.1 %) for rise times <1 µsDisplay count rate6,000 counts / 19,999 counts in high-resolutionCapacitance10 nF to 9999 µFAccuracy: ± (1.0 % + 2)Frequency0.5 Hz to 199.99 kHzAccuracy: ± (0.005 % + 1)Temperature-200 °C to +1090 °C (-328 °F to +1994 °F)Accuracy: ± (1.0 % + 10) °C [± (1.0 + 10) °F] Error: % of reading + number of digits: . DC voltage: 0.1 mV to 1000 VAccuracy: ± (0.05 % + 1). AC voltage: 0.1 mV to 1000 VAccuracy: ± (0.7 % + 4). DC current: 0.1 µA to 10 AAccuracy: ± (0.2 % + 4). AC current: 0.1 µA to 10 AAccuracy: ± (1.0 % + 2). Resistor: 0.1 Ω to 50 MΩAccuracy: ± (0.2 % + 1). Conductivity: 60.00 nSAccuracy: ± (1.0 % + 10). Diode test: 2.0 VAccuracy: ± (2.0 % + 1). Duty cycle: 0.0 % to 99.9 %Accuracy: Within ± (0.2 % per kHz + 0.1 %) for rise times <1 µs. Display count rate: 6,000 counts / 19,999 counts in high-resolution. Capacitance: 10 nF to 9999 µFAccuracy: ± (1.0 % + 2). Frequency: 0.5 Hz to 199.99 kHzAccuracy: ± (0.005 % + 1). Temperature: -200 °C to +1090 °C (-328 °F to +1994 °F)Accuracy: ± (1.0 % + 10) °C [± (1.0 + 10) °F] Error: % of reading + number of digits. Display: LC display with backlight. Battery type: 3x AAA, type-proofed. Operating duration: approx. 400 h. Ambient temperature: Different temperature ranges result from the type-tested batteries used.. Storage temperature: -40 ... 60 °C (-40 ... 140 °F) , without batteries. Degree of protection: IP67. Mass: approx. 690 g. Dimensions: approx. 210 mm x 100 mm x 64 mm (with holster). PCEC approval: . PCEC certificateCE17.2310XPCEC markingEx ia IIC T4 Gb: . PCEC certificate: CE17.2310X. PCEC marking: Ex ia IIC T4 Gb. Note: Remarks: Measurement inside the hazardous area: Ui ≤ 65V, Ii ≤ 5A Measurement outside the hazardous area: Ui ≤ 1000V, Ii ≤ 10A. Scope of delivery: Fluke 28 II EX Ex-holster Alligator clips AC175 Test leads TL175 Batteries Documentation
Specifications
General specifications
| Measuring range | |
| DC voltage0.1 mV to 1000 VAccuracy: ± (0.05 % + 1)AC voltage0.1 mV to 1000 VAccuracy: ± (0.7 % + 4)DC current0.1 µA to 10 AAccuracy: ± (0.2 % + 4)AC current0.1 µA to 10 AAccuracy: ± (1.0 % + 2)Resistor0.1 Ω to 50 MΩAccuracy: ± (0.2 % + 1)Conductivity60.00 nSAccuracy: ± (1.0 % + 10)Diode test2.0 VAccuracy: ± (2.0 % + 1)Duty cycle0.0 % to 99.9 %Accuracy: Within ± (0.2 % per kHz + 0.1 %) for rise times <1 µsDisplay count rate6,000 counts / 19,999 counts in high-resolutionCapacitance10 nF to 9999 µFAccuracy: ± (1.0 % + 2)Frequency0.5 Hz to 199.99 kHzAccuracy: ± (0.005 % + 1)Temperature-200 °C to +1090 °C (-328 °F to +1994 °F)Accuracy: ± (1.0 % + 10) °C [± (1.0 + 10) °F] Error: % of reading + number of digits | DC voltage |
| DC voltage | 0.1 mV to 1000 VAccuracy: ± (0.05 % + 1) |
| AC voltage | 0.1 mV to 1000 VAccuracy: ± (0.7 % + 4) |
| DC current | 0.1 µA to 10 AAccuracy: ± (0.2 % + 4) |
| AC current | 0.1 µA to 10 AAccuracy: ± (1.0 % + 2) |
| Resistor | 0.1 Ω to 50 MΩAccuracy: ± (0.2 % + 1) |
| Conductivity | 60.00 nSAccuracy: ± (1.0 % + 10) |
| Diode test | 2.0 VAccuracy: ± (2.0 % + 1) |
| Duty cycle | 0.0 % to 99.9 %Accuracy: Within ± (0.2 % per kHz + 0.1 %) for rise times <1 µs |
| Display count rate | 6,000 counts / 19,999 counts in high-resolution |
| Capacitance | 10 nF to 9999 µFAccuracy: ± (1.0 % + 2) |
| Frequency | 0.5 Hz to 199.99 kHzAccuracy: ± (0.005 % + 1) |
| Temperature | -200 °C to +1090 °C (-328 °F to +1994 °F)Accuracy: ± (1.0 % + 10) °C [± (1.0 + 10) °F] Error: % of reading + number of digits |
Indicators/operating means
| Display | LC display with backlight |
Electrical specifications
| Battery type | 3x AAA, type-proofed |
| Operating duration | approx. 400 h |
Ambient conditions
| Ambient temperature | Different temperature ranges result from the type-tested batteries used. |
| Storage temperature | -40 ... 60 °C (-40 ... 140 °F) , without batteries |
Mechanical specifications
| Degree of protection | IP67 |
| Mass | approx. 690 g |
| Dimensions | approx. 210 mm x 100 mm x 64 mm (with holster) |
International approvals
| PCEC approval | |
| PCEC certificateCE17.2310XPCEC markingEx ia IIC T4 Gb | PCEC certificate |
| PCEC certificate | CE17.2310X |
| PCEC marking | Ex ia IIC T4 Gb |
General information
| Note | Remarks: Measurement inside the hazardous area: Ui ≤ 65V, Ii ≤ 5A Measurement outside the hazardous area: Ui ≤ 1000V, Ii ≤ 10A |
| Scope of delivery | Fluke 28 II EX Ex-holster Alligator clips AC175 Test leads TL175 Batteries Documentation |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G