IFM SM6001
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Magnetic-inductive volumetric flow meters |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SM6001 be shipped?
SM6001 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SM6001 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SM6001 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SM6001, subject to availability and destination.
Precise measurement of flow, consumption and medium temperature High accuracy, repeatability and measurement dynamics With switching output, analogue output and pulse output Clearly visible 4-digit LED display Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Measuring range | 1.5...396 gph; 0.03...6.6 gpm |
| 1.5...396 gph | 0.03...6.6 gpm |
| Process connection | threaded connection G 1/2 external thread DN15 flat seal |
Application
| Special feature | Gold-plated contacts |
| Application | totaliser function; for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | conductive liquids; water; hydrous media |
| Note on media | conductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C) |
| Medium temperature[°F] [°F] | 14...158 |
| Pressure rating | 16 bar; 232 psi; 1.6 MPa |
| 16 bar | 232 psi |
| MAWP for applications according to CRN | 15.3 bar; 1.53 MPa |
| 15.3 bar | 1.53 MPa |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | 95; (24 V) |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 5 |
| Measuring principle | magnetic-inductive |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Inputs
| Inputs | counter reset |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 200 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Analogue voltage output[V] [V] | 0...10; (scalable) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 1.5...396 gph; 0.03...6.6 gpm |
| 1.5...396 gph | 0.03...6.6 gpm |
| Display range | -475.5...475.5 gph; -7.925...7.925 gpm |
| -475.5...475.5 gph | -7.925...7.925 gpm |
| Resolution | 0.5 gph; 0.01 gpm |
| 0.5 gph | 0.01 gpm |
| Set point SP | 3.5...396.5 gph; 0.06...6.6 gpm |
| 3.5...396.5 gph | 0.06...6.6 gpm |
| Reset point rP | 1.5...394 gph; 0.03...6.57 gpm |
| 1.5...394 gph | 0.03...6.57 gpm |
| Analogue start point ASP | 0...318 gph; 0...5.3 gpm |
| 0...318 gph | 0...5.3 gpm |
| Analogue end point AEP | 78...396 gph; 1.3...6.6 gpm |
| 78...396 gph | 1.3...6.6 gpm |
| In steps of | 0.5 gph; 0.01 gpm |
| Pulse value | 0.01...30 000 000 gal |
| Pulse length[s] [s] | 0,01...2 |
| Measuring range[°F] [°F] | -4...176 |
| Resolution[°F] [°F] | 0.1 |
| Set point SP[°F] [°F] | -2.5...176 |
| Reset point rP[°F] [°F] | -3.5...175 |
| Analogue start point[°F] [°F] | -4...140.5 |
| Analogue end point[°F] [°F] | 31.5...176 |
| In steps of[°F] [°F] | 0.5 |
Accuracy / deviations
| Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) |
| Repeatability | ± 0,2% MEW |
| Accuracy[K] [K] | ± 2,5 (Q > 0,26 gpm) |
Response times
| Response time[s] [s] | 0.15; (dAP = 0, T19) |
| Delay time programmable dS, dr[s] [s] | 0...50 |
| Damping process value dAP[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 20 (Q > 0,26 gpm) |
Software / programming
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 3 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 5 |
| Supported DeviceIDs | default; 570 |
| default | 570 |
Operating conditions
| Ambient temperature[°F] [°F] | 14...140 |
| Storage temperature[°F] [°F] | -13...176 |
| Protection | IP 67 |
Tests / approvals
| EMC | DIN EN 60947-5-9 |
| Shock resistance | DIN IEC 68-2-27; 20 g (11 ms) |
| DIN IEC 68-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 5 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 160 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 546 |
| Housing | cylindrical |
| Inlet pipe length | 3 x DN |
| Outlet pipe length | 1 x DN |
| Dimensions[mm] [mm] | Ø 54 / L = 110 |
| Materials | stainless steel (316L/1.4404); PBT-GF20; PC; FKM; TPE |
| Materials (wetted parts) | stainless steel (316L/1.4404); PEEK; FKM |
| Process connection | threaded connection G 1/2 external thread DN15 flat seal |
Displays / operating elements
| Display | Display unit; 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³); switching status; 2 x LED, yellow; measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit |
| Display unit | 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, 4-digit |
| programming | alphanumeric display, 4-digit |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |