IFM SM6004
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Magnetic-inductive volumetric flow meters |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SM6004 be shipped?
SM6004 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SM6004 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SM6004 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SM6004, subject to availability and destination.
Precise measurement of flow, consumption and medium temperature High accuracy, repeatability and measurement dynamics For use in water cooling circuits With two precise analogue outputs Clearly visible 4-digit LED display
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 2 |
| Measuring range | 0.1...25 l/min; 0.03...6.6 gpm |
| 0.1...25 l/min | 0.03...6.6 gpm |
| Process connection | threaded connection G 1/2 external thread DN15 flat seal |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | conductive liquids; water; hydrous media |
| Note on media | conductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C) |
| Medium temperature[°C] [°C] | -10...70 |
| Pressure rating | 16 bar; 1.6 MPa |
| 16 bar | 1.6 MPa |
| MAWP for applications according to CRN | 15.3 bar; 1.53 MPa |
| 15.3 bar | 1.53 MPa |
Electrical data
| Operating voltage[V] [V] | 20...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | 120; (24 V) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 5 |
| Measuring principle | magnetic-inductive |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Output signal | analogue signal |
| Number of analogue outputs | 2 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 0.1...25 l/min; 0.03...6.6 gpm |
| 0.1...25 l/min | 0.03...6.6 gpm |
| Display range | -30...30 l/min; -7.92...7.92 gpm |
| -30...30 l/min | -7.92...7.92 gpm |
| Resolution | 0.05 l/min; 0.01 gpm |
| 0.05 l/min | 0.01 gpm |
| Analogue start point ASP | 0...20 l/min; 0...5.28 gpm |
| 0...20 l/min | 0...5.28 gpm |
| Analogue end point AEP | 5...25 l/min; 1.32...6.6 gpm |
| 5...25 l/min | 1.32...6.6 gpm |
| In steps of | 0.02 l/min; 0.01 gpm |
| 0.02 l/min | 0.01 gpm |
| Measuring range[°C] [°C] | -20...80 |
| Resolution[°C] [°C] | 0.2 |
| Analogue start point[°C] [°C] | -20...60 |
| Analogue end point[°C] [°C] | 0...80 |
| In steps of[°C] [°C] | 0.2 |
Accuracy / deviations
| Accuracy (in the measuring range) | ± (2 % MW + 0,5 % MEW) |
| Repeatability | ± 0,2% MEW |
| Accuracy[K] [K] | ± 2,5 (Q > 1 l/min) |
Response times
| Response time[s] [s] | 0.15; (dAP = 0, T19) |
| Damping process value dAP[s] [s] | 0...3 |
| Dynamic response T05 / T09[s] [s] | T09 = 20 (Q > 1 l/min) |
Operating conditions
| Ambient temperature[°C] [°C] | -10...60 |
| Storage temperature[°C] [°C] | -25...80 |
| Protection | IP 67 |
Tests / approvals
| EMC | DIN EN 60947-5-9; 500 V withstand voltage (V DC) |
| DIN EN 60947-5-9 | 500 V withstand voltage (V DC) |
| CPA approval | model number; 008MI; accuracy class; -; maximum allowable error; ± 2,5 % FS; Q (min); 0,005 m³/h; Q (t); -; Q (max); 1,5 m³/h |
| model number | 008MI |
| accuracy class | - |
| maximum allowable error | ± 2,5 % FS |
| Q (min) | 0,005 m³/h |
| Q (t) | - |
| Q (max) | 1,5 m³/h |
| Shock resistance | DIN IEC 68-2-27; 20 g (11 ms) |
| DIN IEC 68-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 5 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 175 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 481.5 |
| Housing | cylindrical |
| Inlet pipe length | 3 x DN |
| Outlet pipe length | 1 x DN |
| Dimensions[mm] [mm] | Ø 54 / L = 110 |
| Materials | stainless steel (316L/1.4404); PBT-GF20; PC; FKM; TPE |
| Materials (wetted parts) | stainless steel (316L/1.4404); PEEK; FKM |
| Process connection | threaded connection G 1/2 external thread DN15 flat seal |
Displays / operating elements
| Display | Display unit; 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F); measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit |
| Display unit | l/min; m³/h; gpm; gph; °C; °F |
| measured values | alphanumeric display, 4-digit |
| programming | alphanumeric display, 4-digit |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |