Available on request

IFM SM2001

MPN: SM2001 · Brand: IFM
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryMagnetic-inductive volumetric flow meters
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can SM2001 be shipped?

SM2001 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SM2001 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SM2001 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SM2001, subject to availability and destination.

Precise measurement of flow, consumption and medium temperature High accuracy, repeatability and measurement dynamics Precise empty pipe detection With switching output, analogue output and pulse output Clearly visible 4-digit LED display Convenient operation via buttons or parameter setting via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range80...9600 gph; 1.3...160 gpm
80...9600 gph1.3...160 gpm
Process connectionthreaded connection G 2 external thread DN50 flat seal

Application

Special featureGold-plated contacts
Applicationtotaliser function; empty pipe detection; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on mediaconductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C)
Medium temperature[°F] [°F]14...194
Pressure rating16 bar; 232 psi; 1.6 MPa
16 bar232 psi
MAWP for applications according to CRN8.9 bar; 0.89 MPa
8.9 bar0.89 MPa

Electrical data

Operating voltage[V] [V]18...32 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]5
Measuring principlemagnetic-inductive

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

Inputscounter reset

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable)
Min. load resistance[Ω] [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output[Hz] [Hz]0.1...10000

Measuring/setting range

Measuring range80...9600 gph; 1.3...160 gpm
80...9600 gph1.3...160 gpm
Display range-11520...11520 gph; -190...190 gpm
-11520...11520 gph-190...190 gpm
Resolution5 gph; 0.1 gpm
5 gph0.1 gpm
Set point SP130...9600 gph; 2.1...160 gpm
130...9600 gph2.1...160 gpm
Reset point rP80...9550 gph; 1.3...159.2 gpm
80...9550 gph1.3...159.2 gpm
Analogue start point ASP0...7680 gph; 0...128 gpm
0...7680 gph0...128 gpm
Analogue end point AEP1920...9600 gph; 32...160 gpm
1920...9600 gph32...160 gpm
Low flow cut-off LFC< 240 gph; < 4 gpm
< 240 gph< 4 gpm
In steps of0.02 gal
Measuring dynamics1:120
Pulse value0.02...160 E06 gal
Pulse length[s] [s]0,008...2
Measuring range[°F] [°F]-4...176
Display range[°F] [°F]-40...212
Resolution[°F] [°F]0.5
Set point SP[°F] [°F]-2...176
Reset point rP[°F] [°F]-3...175
Analogue start point[°F] [°F]-4...140
Analogue end point[°F] [°F]32...176
In steps of[°F] [°F]0.5

Accuracy / deviations

Accuracy (in the measuring range)± (0,8 % MW + 0,5 % MEW)
Repeatability± 0,2% MEW
Temperature drift± 0,0185 °F / K
Accuracy[K] [K]± 1 (77 °F; Q > 4 gpm)

Response times

Response time[s] [s]0.35; (dAP = 0)
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]T09 = 3 (Q > 4 gpm)

Software / programming

Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesSmart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionProcess data variable
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time[ms] [ms]5
Supported DeviceIDsdefault; 390
default390

Operating conditions

Ambient temperature[°F] [°F]14...140
Storage temperature[°F] [°F]-13...176
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 60947-5-9
Shock resistanceDIN EN 60068-2-27; 20 g (11 ms)
DIN EN 60068-2-2720 g (11 ms)
Vibration resistanceDIN EN 60068-2-6; 5 g (10...2000 Hz)
DIN EN 60068-2-65 g (10...2000 Hz)
MTTF[years] [years]85
UL approvalUL approval no.; I008; File number UL; E174189
UL approval no.I008
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]3069.2
Housingrectangular
Inlet pipe length3 x DN
Outlet pipe length1 x DN
Dimensions[mm] [mm]200 x 103 x 117
Materialsstainless steel (316L/1.4404); stainless steel (316Ti/1.4571); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts)Pipe section: stainless steel (316L/1.4404); Process connection sealing: NBR reinforced fibre Flat seal; FKM; stainless steel (316Ti/1.4571); PEEK
Process connectionthreaded connection G 2 external thread DN50 flat seal

Displays / operating elements

DisplayDisplay unit; 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³); switching status; 2 x LED, yellow; measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit
Display unit6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Accessories

Items suppliedsealings: 2, Centellen; Label

Remarks

RemarksMW = measured value; MEW = Final value of the measuring range
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More IFM parts

IFM O8H205Available on requestIFM O8H205
MPN: O8H205 · IFM
Price on request
Request a quote
IFM O8H206Available on requestIFM O8H206
MPN: O8H206 · IFM
Price on request
Request a quote
IFM O8H207Available on requestIFM O8H207
MPN: O8H207 · IFM
Price on request
Request a quote
IFM O8H202Available on requestIFM O8H202
MPN: O8H202 · IFM
Price on request
Request a quote