IFM SM0504
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SM0504 be shipped?
SM0504 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SM0504 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SM0504 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SM0504, subject to availability and destination.
Precise measurement of flow, consumption and medium temperature High accuracy, repeatability and measurement dynamics For use in water cooling circuits With two precise analogue outputs Clearly visible 4-digit LED display
Specifications
Product characteristics
| Number of inputs and outputs | Number of analogue outputs: 2 |
| Measuring range | 6...1800 gph; 0.1...30 gpm |
| 6...1800 gph | 0.1...30 gpm |
| Process connection | threaded connection G 1 external thread DN25 flat seal |
Application
| Special feature | Gold-plated contacts |
| Application | for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | conductive liquids; water; hydrous media |
| Note on media | conductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C) |
| Medium temperature[°F] [°F] | 14...158 |
| Pressure rating | 16 bar; 232 psi; 1.6 MPa |
| 16 bar | 232 psi |
| MAWP for applications according to CRN | 10.4 bar; 1.04 MPa |
| 10.4 bar | 1.04 MPa |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | 95; (24 V) |
| Min. insulation resistance[MΩ] [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 5 |
| Measuring principle | magnetic-inductive |
Inputs / outputs
| Number of inputs and outputs | Number of analogue outputs: 2 |
Outputs
| Total number of outputs | 2 |
| Output signal | analogue signal |
| Number of analogue outputs | 2 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Overload protection | yes |
Measuring/setting range
| Measuring range | 6...1800 gph; 0.1...30 gpm |
| 6...1800 gph | 0.1...30 gpm |
| Display range | -1902...1902 gph; -31.7...31.7 gpm |
| -1902...1902 gph | -31.7...31.7 gpm |
| Resolution | 2 gph; 0.05 gpm |
| 2 gph | 0.05 gpm |
| Analogue start point ASP | 0...1268 gph; 0...21.15 gpm |
| 0...1268 gph | 0...21.15 gpm |
| Analogue end point AEP | 318...1800 gph; 5.3...30 gpm |
| 318...1800 gph | 5.3...30 gpm |
| In steps of | 2 gph; 0.05 gpm |
| Measuring range[°F] [°F] | -4...176 |
| Resolution[°F] [°F] | 0.5 |
| Analogue start point[°F] [°F] | -4...140.5 |
| Analogue end point[°F] [°F] | 31.5...176 |
| In steps of[°F] [°F] | 0.5 |
Accuracy / deviations
| Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) |
| Repeatability | ± 0,2% MEW |
| Accuracy[K] [K] | ± 4,5 (Q > 0,26 gpm) |
Response times
| Response time[s] [s] | 0.15; (dAP = 0) |
| Damping process value dAP[s] [s] | 0...5 |
| Dynamic response T05 / T09[s] [s] | T09 = 20 (Q > 0,26 gpm) |
Operating conditions
| Ambient temperature[°F] [°F] | 14...140 |
| Storage temperature[°F] [°F] | -13...176 |
| Protection | IP 67 |
Tests / approvals
| EMC | DIN EN 60947-5-9; 500 V withstand voltage (V DC) |
| DIN EN 60947-5-9 | 500 V withstand voltage (V DC) |
| Shock resistance | DIN IEC 68-2-27; 20 g (11 ms) |
| DIN IEC 68-2-27 | 20 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6; 5 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
| MTTF[years] [years] | 175 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 576 |
| Housing | cylindrical |
| Inlet pipe length | 5 x DN |
| Outlet pipe length | 2 x DN |
| Dimensions[mm] [mm] | Ø 54 / L = 110 |
| Materials | stainless steel (316L/1.4404); PBT-GF20; PC; EPDM/X |
| Materials (wetted parts) | stainless steel (316L/1.4404); Hastelloy; PEEK; FKM |
| Process connection | threaded connection G 1 external thread DN25 flat seal |
Displays / operating elements
| Display | Display unit; 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F); measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit |
| Display unit | l/min; m³/h; gpm; gph; °C; °F |
| measured values | alphanumeric display, 4-digit |
| programming | alphanumeric display, 4-digit |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |