Quick facts
| Availability | Confirmed on request |
| Category | X20 electronics module communication |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can X20CS2770 be shipped?
X20CS2770 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20CS2770 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20CS2770 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20CS2770, subject to availability and destination.
• 2 CAN bus interfaces for serial, remote connection of complex devices to the X20 system
• Integrated terminating resistors
In addition to the standard I/O, complex devices often need to be connected. The X20 CS communication modules are intended precisely for cases like this. As normal X20 electronics modules, they can be placed anywhere on the remote backplane.
Accessories
Required accessories (order separately)
| X20BM15 | Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe… |
| X20BM11 | Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Specifications
Short description
| Communication module | 2x CAN bus |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – Data transfer | Yes, using LED status indicator |
| Diagnostics – Terminating resistor | Yes, using LED status indicator |
| Power consumption – Bus | 0.01 W |
| Power consumption – Internal I/O | 0.55 W (Rev. ≤D0 1.5 W) |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – CCS | Yes |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| Certifications – KC | Yes |
| B&R ID code | 0xA009 |
| Status indicators | Data transfer, terminating resistor, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Interfaces
| Interface IF1 – Signal | CAN bus |
| Interface IF1 – Variant | Connection via 12-pin terminal block X20TB12 |
| Interface IF1 – Max. distance | 1000 m |
| Interface IF1 – Transfer rate | Max. 1 Mbit/s |
| Interface IF1 – Terminating resistor | Integrated in module |
| Interface IF1 – Controller | SJA 1000 |
| Interface IF2 – Signal | CAN bus |
| Interface IF2 – Variant | Connection via 12-pin terminal block X20TB12 |
| Interface IF2 – Max. distance | 1000 m |
| Interface IF2 – Transfer rate | Max. 1 Mbit/s |
| Interface IF2 – Terminating resistor | Integrated in module |
| Interface IF2 – Controller | SJA 1000 |
Electrical properties
| Electrical isolation | CAN (IF1, IF2) isolated from bus and I/O power supply; CAN (IF1, IF2) not isolated from each other |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | See section "Derating". |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately. ; Order 1x bus module X20BM11 separately. |
| Pitch | 12.5 +0.2 mm |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| Data sheet X20CS2770 | PDF · 1 MB · 3.46 (06/25/2025) - EN |
| X20 Package leaflet ATEX/CSA | PDF · 2 MB · 1.4 (09/17/2024) |
| X20 System User´s Manual | PDF · 50 MB · 4.40 (03/10/2026) - EN |
CAD & dimension drawings
| 3D File DXF/STEP X20 Electronic module | ZIP · 10 KB · 1.0 (10/17/2005) |
| 3D File STEP X20 I/O-Slice | ZIP · 872 KB · 1.1 (03/13/2019) |
| Dimensions PDF X20 Electronic module | PDF · 3 KB · 1.0 (10/17/2005) |
Certificates (14)
| 2226379 CSA Certificate of Compliance X20 X67 | PDF · 205 KB · 2026_09 (09/21/2026) |
| 64331_A1 BV Certificate of Compliance X20 | PDF · 1 MB · 2026_05 (05/05/2026) |
| ABS Certificate of Product Design Assessment - X20 IO Series | PDF · 454 KB · 2.00 (01/13/2025) |
| CCS Type Approval Certificate - X20 | PDF · 285 KB · 1.00 (06/28/2024) |
| E115267 UL Certificate of Compliance X20 | PDF · 3 MB · 2026_08_27 (08/27/2026) |
| EU Data Act - X20 IO - Connected Product Information Notice | PDF · 92 KB · 1.00 (09/30/2025) |
| EU Declaration ATEX X20 | PDF · 218 KB · 2023-07 (09/05/2023) |
| EU Declaration of conformity PLC X20 | PDF · 169 KB · 2021/10 (11/08/2021) |
| FTZU 09 ATEX 0083X | PDF · 771 KB · 3.00 (10/12/2021) |
| KR Type Approval Certificate MIL39390-AC003 (X20 System) | PDF · 320 KB · 2.0 (05/05/2025) |
| Lloyds Register (X20 only) | PDF · 884 KB · 1.30 (07/07/2025) |
| TAA00000BJ DNV Type Approval Certificate X20 | PDF · 186 KB · 13.0 (05/04/2026) |
| UK Declaration PLC X20 | PDF · 151 KB · 2024-01 (01/18/2024) |
| X20, X67 KC certificates | PDF · 7 MB · 2.00 (08/17/2026) |
More B&R parts
Available on requestB&R X20CS1013 – Communication module, DALI master
Available on requestB&R X20CS1020 – Communication module, 1x RS232
Available on requestB&R X20CS1030 – Communication module, 1x RS485/RS422
Available on requestB&R X20CS1070 – Communication module, 1x CAN bus
Available on requestB&R X20cSA4430 – I/O module, 2x 2 safe type A analog inputs, 0.5 to 25 mA
Available on requestB&R X20cSC2212 – I/O module, 6 safe type A digital inputs, 6 pulse outputs
Available on requestB&R X20cSC2432 – I/O module, 2 safe type A digital inputs, 2 pulse outputs
Available on requestB&R X20cSD1207 – I/O module, 1 safe type A digital counter channel, 7 kHz