B&R 4PPC80.0573-11A – Power Panel C80, glass front (anti-glare)
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Power Panel C80 |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 1 kg |
Shipping & availability
When can 4PPC80.0573-11A be shipped?
4PPC80.0573-11A is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 4PPC80.0573-11A in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 4PPC80.0573-11A and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 4PPC80.0573-11A, subject to availability and destination.
Power Panel C80, glass front (anti-glare), fieldbus interfaces: 2x CAN bus. CPU and memory: 1600 MHz (Intel Atom E3940), 4 GB DRAM, 64 kB FRAM, 4 GB onboard flash drive. Display and touch screen: 5.7", 640 x 480 (VGA) resolution, projected capacitive touch screen, multi-touch support, anti-glare glass front with black frame, landscape and portrait format configurable with software. Interfaces: 1x POWERLINK, 1x Ethernet 10/100/1000 Mbit/s, 1x X2X Link, 2x USB 3.0, 2x CAN bus.
Accessories
Optional accessories (8)
| 0TB6102.3100-00 | Terminal blocks — Accessory 2-pin cage clamp terminal block (3.81) |
| 0TB1210.3100 | Terminal blocks — Two-row 10-pin terminal block 0TB1210.3100 is used to connect to the button/switch interface of the Automation Panel 9xD and to the interfa… |
| 5ACCRHMI.0018-000 | Accessories — HMI C80/PPC1200 battery compartment - 1x battery holder C80/PPC1200 - 1x battery including circuit board |
| 6ACCRPP3.0001-000 | Other — This installation kit contains the following replacement parts: 9 retaining clips with torque limiting; 1x 2-pin cage clamp terminal block;… |
| 0TB6102.3000-00 | Terminal blocks — 2-pin accessory screw clamp terminal block (3.81) |
| 5MMUSB.4096-02 | USB accessories — USB 3.0 flash drive 4096 MB SLC - Only for HMI products |
| 5MMUSB.4096-01 | USB accessories — 4 GB; USB 1.1, USB 2.0; High transfer rate; High data storage; Ambient temperature during operation: 0 to 70°C USB 2.0 flash drive 4096 MB… |
| 5MMUSB.2048-01 | USB accessories — 2 GB; USB 1.1, USB 2.0; High transfer rate; High data retention; Ambient temperature during operation: 0 to 70°C USB 2.0 flash drive 2048 M… |
Specifications
General information
| Support – mapp View | Yes |
| Support – Controller redundancy | No |
| Support – Visual Components support | Yes |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Light transmission | 70% |
| B&R ID code | 0xA408 |
| Cooling | Passive |
| Power button | No |
| Reset button | Yes |
| Status indicators | Operating state, terminating resistor LEDs, interface status |
| Buzzer | No |
Controller
| Processor – Data code | 32 kB |
| Processor – Program code | 32 kB |
| Processor – Type | Intel Atom x5-E3940 |
| Processor – Clock frequency | 1600 MHz |
| Processor – Total number of cores | 4 |
| Processor – Architecture | 14 nm |
| Processor – Thermal design power (TDP) | 9.5 W |
| Processor – L2 cache | 2 MB |
| Processor – Intel 64 architecture | Yes |
| Processor – Intel Hyper-Threading Technology | No |
| Processor – Intel vPro Technology | No |
| Processor – Intel Virtualization Technology (VT-x) | Yes |
| Processor – Intel Virtualization Technology for Directed I/O (VT-d) | Yes |
| Processor – Enhanced Intel SpeedStep Technology | Yes |
| Real-time clock – Accuracy | At 25°C: Typ. 12 ppm (1 second) per day " data-placement="top" data-html="true" data-container="body" data-content="At max. specified ambient temperature: Typ. 58 ppm (5 seconds) - worst case 220 ppm (19 seconds)."> |
| Real-time clock – Retention time | Approx. 8 years |
| Real-time clock – Battery-backed | Yes |
| Memory – Type | LPDDR4 SDRAM |
| Memory – Memory size | 4 GB |
| Memory – Velocity | DDR4L-2133 |
| Memory – Memory interface width | Dual channel |
| Memory – Removable | No |
| Graphics – Controller | Intel HD Graphics |
| Graphics – Max. dynamic graphics frequency | 600 MHz |
| Graphics – Color depth | Max. 32-bit |
| Graphics – DirectX support | 12 |
| Graphics – OpenGL support | 4.3 |
| Application memory – Theoretical | 150 TBW |
| Application memory – Client workload | 90 TBW " data-placement="top" data-html="true" data-container="body" data-content="TBW = Terabytes written"> |
| Application memory – Type | Flash memory 5 GB NVMe pSLC |
| Application memory – Data retention | 10 years |
| Application memory – Error-correcting code (ECC) | Yes |
| Real-time clock " data-placement="top" data-html="true" data-container="body" data-content="The real-time clock is backed up by a battery."> | Nonvolatile, resolution 1 s |
| Mode/Node switches | No |
| Remanent variables | 64 kB FRAM, retention >10 years " data-placement="top" data-html="true" data-container="body" data-content="The memory size for remanent variables is configurable in Automation Studio. Permanent variables are not supported."> |
| Shortest task class cycle time | 0.4 ms |
| Typical instruction cycle time | 0.01 µs |
| Chipset | Apollo Lake |
| Power management | ACPI 5.0 |
Display
| Viewing angles – Horizontal | Direction L / Direction R = Typ. 80° |
| Viewing angles – Vertical | Direction U / Direction D = Typ. 80° |
| Backlight – Type | LED |
| Backlight – Brightness | Typ. 550 cd/m² |
| Backlight – Half-brightness time " data-placement="top" data-html="true" data-container="body" data-content="At 25°C ambient temperature. Reducing the brightness by 50% can typically increase the half-brightness time by approximately 50%."> | 50,000 h |
| Filter glass – Transmittance | ≥85% |
| Touch screen – Type | Multi-touch |
| Touch screen – Technology | PCT (projected capacitive touch) |
| Touch screen – Surface | Glass, chemically hardened (6H), anti-glare |
| Type | TFT color |
| Diagonal | 5.7" |
| Colors | 16.7 million LVDS |
| Resolution | VGA; 640 x 480 px |
| Contrast | Typ. 900:1 |
| Screen rotation | Yes " data-placement="top" data-html="true" data-container="body" data-content="Can be set using software."> |
Interfaces
| Interface IF1 – Fieldbus | POWERLINK V2 managing or controlled node |
| Interface IF1 – Type | Type 4 " data-placement="top" data-html="true" data-container="body" data-content="See section "Communication → POWERLINK → General information → Hardware - IF/LS" in Automation Help"> |
| Interface IF1 – Variant | 1x RJ45 shielded |
| Interface IF1 – Line length | Max. 100 m between 2 nodes (segment length) |
| Interface IF1 – Max. transfer rate | 100 Mbit/s |
| Interface IF2 – Physical layer | 10BASE-T/100BASE-TX/1000BASE-T |
| Interface IF2 – Half-duplex | Yes |
| Interface IF2 – Full-duplex | Yes |
| Interface IF2 – Autonegotiation | Yes |
| Interface IF2 – Auto-MDI/MDIX | Yes |
| Interface IF2 – Type | Ethernet |
| Interface IF2 – Variant | 1x RJ45 shielded |
| Interface IF2 – Line length | Max. 100 m between 2 nodes (segment length) |
| Interface IF2 – Max. transfer rate | 10/100/1000 Mbit/s |
| Interface IF3 – Variant | Internal Ethernet interface |
| Interface IF4 – Type | USB 3.0 |
| Interface IF4 – Variant | Type A |
| Interface IF4 – Current-carrying capacity | 1 A |
| Interface IF5 – Fieldbus | USB 3.0 |
| Interface IF5 – Variant | Type A |
| Interface IF5 – Current-carrying capacity | 1 A |
| Interface IF6 – Fieldbus | X2X Link master |
| Interface IF6 – Max. distance | Max. 100 m between 2 nodes (segment length) |
| Interface IF7 – Type | CAN bus |
| Interface IF7 – Variant | 3 pins of the 10-pin multipoint connector; Galvanically isolated |
| Interface IF8 – Bus length ≤25 m | 1 Mbit/s |
| Interface IF8 – Bus length ≤60 m | 500 kbit/s |
| Interface IF8 – Bus length ≤200 m | 250 kbit/s |
| Interface IF8 – Bus length ≤1000 m | 50 kbit/s |
| Interface IF8 – Type | CAN bus |
| Interface IF8 – Variant | 3 pins of the 10-pin multipoint connector |
Electrical properties
| Nominal voltage | 24 VDC, SELV/PELV " data-placement="top" data-html="true" data-container="body" data-content="IEC 61010-2-201 requirements must be observed; see section "+24 VDC power supply" in the user's manual."> |
| Nominal current | 1.2 A |
| Operating voltage | 24 VDC ±25% |
| Inrush current | Typ. 5 A, max. 100 A for < 50 μs |
| Power consumption " data-placement="top" data-html="true" data-container="body" data-content="Power consumption including all interfaces."> | 28.8 W |
| Fuse | 10 A fast, internal " data-placement="top" data-html="true" data-container="body" data-content="The internal fuse cannot be replaced by the user or reset."> |
| Reverse polarity protection | Yes |
| Galvanic isolation | No |
| Electrical isolation | POWERLINK (IF1), Ethernet (IF2), X2X Link (IF6) and CAN (IF7) to each other, to other interfaces and to the base device |
Operating conditions
| Permissible mounting orientations " data-placement="top" data-html="true" data-container="body" data-content="For details, see section "Installation and wiring"."> – Standard mounting orientation | Vertical |
| Permissible mounting orientations " data-placement="top" data-html="true" data-container="body" data-content="For details, see section "Installation and wiring"."> – Rotation | In 90° increments (portrait/landscape) |
| Degree of protection per EN 60529 | Rev. G5 and later: IP65 front; Up to Rev. G0: IP55 front; Back: IP20 |
Ambient conditions
| Temperature – Operation | -20 to 60°C " data-placement="top" data-html="true" data-container="body" data-content="The maximum ambient temperature is typically derated 1°C per 1000 meters starting at 500 m above sea level."> |
| Temperature – Storage | -20 to 80°C |
| Temperature – Transport | -20 to 80°C |
| Elevation – Operation | Max. 3000 m " data-placement="top" data-html="true" data-container="body" data-content="The maximum ambient temperature is typically derated 1°C per 1000 meters starting at 500 m above sea level."> |
| Relative humidity | See section "Temperature/Humidity diagrams". |
Mechanical properties
| Front – Design | Black |
| Dimensions – Width | 203 mm |
| Dimensions – Height | 145 mm |
| Dimensions – Depth | 44.7 mm |
| Weight | 1 kg |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
| Installation- / EMC-Guide | PDF · 20 MB · 1.43 (12/20/2022) - EN |
| Power Panel C80 Model number key | PDF · 124 KB · 2.00 (04/25/2024) |
| Power Panel C80 user's manual | PDF · 8 MB · 1.06 (12/10/2024) - EN |
CAD & dimension drawings
| 3D files DXF/STP 4PPC80.0573-1xx | ZIP · 3 MB · 1.00 (04/14/2021) |
Certificates (1)
| UL61010-1 Certificate of Compliance C80, T80, PPC1200 | PDF · 119 KB · 1.00 (01/15/2024) |
More B&R parts
Available on requestB&R 4PPC70.101N-23B – Power Panel C70, 10.1", portrait format
Available on requestB&R 4PPC70.101N-23W – Power Panel C70, 10.1", portrait format
Available on requestB&R 4PPC80.0573-10A – Power Panel C80, glass front (anti-glare). CPU and memory…
Available on requestB&R 4PPC80.0573-10B – Power Panel C80, glass front. CPU and memory: 1600 MHz…
Available on requestB&R 4PPC80.0573-11B – Power Panel C80, glass front
Available on requestB&R 4PPC80.0573-12A – Power Panel C80, glass front (anti-glare)
Available on requestB&R 4PPC80.0573-12B – Power Panel C80, glass front
Available on requestB&R 4PPC80.0573-13A – Power Panel C80, glass front (anti-glare)