Relay module; Nominal input voltage: 24 … 230 V AC/DC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; Yellow status indicator; Module width: 6 mm
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Relay and Optocoupler Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 857-369 be shipped?
857-369 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 857-369 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 857-369 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 857-369, subject to availability and destination.
Relay module; Nominal input voltage: 24 … 230 V AC/DC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; Yellow status indicator; Module width: 6 mm 857-369
Specifications
Notes
| Safety Information | Adjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements. |
| Note | To prevent damaging the gold layer, 30 V switching voltages and 50 mA currents must not be exceeded. Higher switching power eventually evaporates the gold layer. The resulting deposits in the housing may reduce service life., To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit. |
Technical data - Control circuit
| Nominal input voltage U<sub>N</sub> | 24 … 230 VAC/VDC |
| Input voltage range | -30 … +10 % |
| Nominal input current at U<sub>N</sub> | 4 mA (230 VAC); 20 mA (24 VDC) |
| Nominal frequency range (input voltage) | 50 … 60 HzAC / 0 HzDC |
Technical data - Load circuit
| Number of changeover/switchover contacts | 1 |
| Contact material (relay) | AgNi + Au |
| Limiting continuous current | 6 A |
| Inrush current (resistive) max. | (AC) 20 A / 0.02 s |
| Switching Voltage, Max. | 250 VAC |
| Switching power (resistive) max. | AC 1500 VA; DC (see load limit curve) |
| Switching capacity | AC-15: 3 A / 250 VAC; DC-13: 2 A / 24 VDC |
| Recommended minimum load | 1 V / 1 mA / 1 mW |
| Pull-in time (typ.) | 15 ms |
| Drop-out time (typ.) | 25 ms |
| Bounce time (typ.) | 3.5 ms |
| Electrical life (NO; resistive load; 23 °C) | 50 x 10³ switching operations |
| Mechanical life | 5 x 10⁶ switching operations |
| Switching frequency with/without load (max.) | 6 min-1 / 60 min-1 |
Technical data - Signaling
| Status indicator | Yellow LED |
Safety and protection
| Rated voltage | 300 V |
| Rated impulse withstand voltage | 4 kV |
| Type of circuits | Mains circuits |
| Overvoltage category | III |
| Pollution degree | 2 |
| Dielectric strength (control/load circuit) (AC, 1 min) | 3.51 kVrms |
| Dielectric strength (open contact) (AC, 1 min) | 1 kVrms |
| Insulation type (control/load circuit) | Reinforced insulation (safe isolation) |
| Insulation type (between adjacent devices of the same type) | Double insulation (safe isolation) |
| Insulation type (to adjacent devices of different types) | Basic insulation |
| Safety Information | Adjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements. |
| Protection type | IP20 |
Connection data
| Connection technology | Push-in CAGE CLAMP® |
| Solid conductor | 0.34 … 2.5 mm² / 22 … 14 AWG |
| Fine-stranded conductor | 0.34 … 2.5 mm² / 22 … 14 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.34 … 1.5 mm² / 22 … 16 AWG |
| Strip length | 9 … 10 mm / 0.35 … 0.39 inches |
Physical data
| Width | 6 mm / 0.236 inches |
| Height | 94 mm / 3.701 inches |
| Depth from upper-edge of DIN-rail | 81 mm / 3.189 inches |
Mechanical data
| Mounting type | DIN-35 rail |
| Mounting position | Horizontal (standing/lying); vertical |
Material data
| Note (material data) | Information on material specifications can be found here |
| Insulation material (main housing) | Polyamide (PA66) |
| Material group | I |
| Flammability class per UL94 | V0 |
| Fire load | 0.484 MJ |
| Weight | 31.9 g |
Environmental requirements
| Ambient temperature (operation at U<sub>N</sub>) | -25 … +70 °C |
| Ambient temperature (storage) | -40 … +70 °C |
| Processing temperature | -25 … +50 °C |
| Temperature range of connection cable | ≥ (Tambient + 30 K) |
| Relative humidity | 5 … 85 % (no condensation permissible) |
| Operating altitude (max.) | 2000 m |
Standards and specifications
| Standards/specifications | EN 50121-3-2, EN 61010-2-201, EN 61810-1, EN 61373, EN 61000-6-2, EN 61000-6-3, EN 50121-3, UL 508 |
Basic relay
| WAGO Basic Relay | 857-151 |
Commercial data
| PU (SPU) | 25 (1) pcs |
| Packaging type | box |
| Country of origin | DE |
| GTIN | 4050821854241 |
| Customs tariff number | 85364900990 |
Product Classification
| UNSPSC | 39122325 |
| eCl@ss 10.0 | 27-37-16-01 |
| eCl@ss 9.0 | 27-37-16-01 |
| ETIM 9.0 | EC001437 |
| ETIM 10.0 | EC001437 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 1303-86-2, 1317-36-8, 7439-92-1, 79-94-7 |
| REACH Candidate List Substance | 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | 0891d92a-b9b0-4855-a374-3f4c7d8bcec6 |
| SCIP notification number (Belgium) | 3d6ce96b-95c2-45ca-9c75-c48432a5185f |
| SCIP notification number (Bulgaria) | 3eb596a0-fb70-479d-aa2f-992ee8d6da2a |
| SCIP notification number (Czech Republic) | b067e2e6-b27e-489d-b6ce-e8a58bf12ab3 |
| SCIP notification number (Denmark) | 736ec7f4-e597-4f9a-9f8d-e6e1d89224cb |
| SCIP notification number (Finland) | 0e46608a-ada5-42bc-a1e2-3cd98f6f5117 |
| SCIP notification number (France) | ce145d34-e7ee-4421-ba57-5016df2c4aa9 |
| SCIP notification number (Germany) | cf5584f3-5fcd-4275-b373-70c672f11f18 |
| SCIP notification number (Hungary) | 7b26aae5-cb7d-40b7-becb-f97e3d03ff32 |
| SCIP notification number (Italy) | d63eee63-1ca0-49a7-bcf1-e4345d48419d |
| SCIP notification number (Netherlands) | ce9882fe-9872-4be0-9614-5bcdf964b46a |
| SCIP notification number (Poland) | 1482eef4-4a89-4cd2-bd10-fe7e0efba63f |
| SCIP notification number (Romania) | a3805355-5493-4993-bb06-a6fab5877d65 |
| SCIP notification number (Sweden) | 75a7959b-0f84-4330-8630-470a2d3b43e1 |