2-conductor through terminal block; 50 mm²; lateral marker slots; only for DIN 35 x 15 rail; POWER CAGE CLAMP; 50,00 mm²; blue
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Rail-Mount Terminal Blocks |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 285-154 be shipped?
285-154 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 285-154 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 285-154 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 285-154, subject to availability and destination.
<h2>High-current terminal block, 285 Series, power cage clamp</h2><br/><br/>Our through terminal block (item number 285-154) makes connections quick and easy. Conductors can only be connected to this through terminal block if their strip length is 32 mm . This product features conductor terminals and utilizes POWER CAGE CLAMP. The POWER CAGE CLAMP is perfect for connecting large conductor cross-sections. This universal connector is both reliable and maintenance-free. What’s more, you can use it to connect all types of conductors and the clamping point can be locked open, making it easier to use. You do not need to use a torque wrench or prepare the conductor. For example, crimping ferrules is not necessary. This through terminal block is suitable for conductor cross sections ranging from 10 mm² to 50 mm².<br/><br/><h3></h3>
Specifications
Electrical data - Ratings per IEC/EN
| Ratings per | IEC/EN 60947-7-1 |
| Nominal voltage (III/3) | 1000 V |
| Rated impulse withstand voltage (III / 3) | 8 kV |
| Rated current | 150 A |
| Legend (ratings) | (III / 3) ≙ Overvoltage category III / Pollution degree 3 |
| Ratings per | IEC/EN 60947-7-1 / IEC/EN 60947-7-1 / IEC/EN 60947-7-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 1000 V |
| Rated impulse withstand voltage | 8 kV |
| Rated current | 150 A |
Electrical data - Ratings per UL
| Approvals per | UL 1059 |
| Rated voltage UL (Use Group B) | 600 V |
| Rated current UL (Use Group B) | 150 A |
| Rated voltage UL (Use Group C) | 600 V |
| Rated current UL (Use Group C) | 150 A |
| Approvals per | UL 1059 / UL 1059 / UL 1059 |
| Use group | B / C / D |
| Rated voltage | 600 V / 600 V |
| Rated current | 150 A / 150 A |
Electrical data - Ratings per CSA
| Approvals per | CSA 22.2 No 158 |
| Rated voltage CSA (Use Group B) | 600 V |
| Rated current CSA (Use Group B) | 150 A |
| Rated voltage CSA (Use Group C) | 600 V |
| Rated current CSA (Use Group D) | 150 A |
| Approvals per | CSA 22.2 No 158 / CSA 22.2 No 158 / CSA 22.2 No 158 |
| Use group | B / C / D |
| Rated voltage | 600 V / 600 V |
| Rated current | 150 A |
Electrical data - Power Loss
| Power loss, per pole (potential) | 4.725 W |
| Rated current I<sub>N</sub> for power loss specification | 150 A |
| Resistance value for specified, current-dependent power loss | 0 Ω |
Electrical data - General information
| Wiring direction | Side-entry wiring |
Connection data
| Clamping units | 2 |
| Total number of potentials | 1 |
| Number of levels | 1 |
| Number of jumper slots | 2 |
Connection data - Connection 1
| Connection technology | POWER CAGE CLAMP |
| Actuation type | T-wrench; 8 mm |
| Connectable conductor materials | Copper |
| Nominal cross-section | 50 mm² |
| Solid conductor | 10 … 50 mm² / 8 … 1/0 AWG |
| Stranded conductor | 10 … 50 mm² / 8 … 1/0 AWG |
| Fine-stranded conductor | 10 … 70 mm² / 8 … 2/0 AWG |
| Fine-stranded conductor; with insulated ferrule | 10 … 50 mm² / 8 … 1/0 AWG |
| Fine-stranded conductor; with uninsulated ferrule | 10 … 50 mm² / 8 … 1/0 AWG |
| Strip length | 32 mm / 1.26 inches |
| Wiring direction | Side-entry wiring |
Physical data
| Width | 20 mm / 0.787 inches |
| Height | 94 mm / 3.701 inches |
| Depth from upper-edge of DIN-rail | 87 mm / 3.425 inches |
Mechanical data
| Mounting type | DIN-35 x 15 rail, DIN-rail 35 x 15 |
| Mounting (note) | only suitable for DIN 35 x 15 rail |
| Marking level | Side marking |
Material data
| Note (material data) | Information on material specifications can be found here |
| Color | blue |
| Material group | I |
| Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 |
| Fire load | 1.798 MJ |
| Weight | 158.7 g |
Environmental requirements
| Processing temperature | -35 … +85 °C |
| Continuous operating temperature | -60 … +105 °C |
Environmental requirements - Environmental Testing
| Test specification: <br/>Railway applications –<br/>Rolling stock –<br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
| Test procedure: <br/>Railway applications – <br/>Rolling stock equipment – <br/>Vibration and shock tests | DIN EN 61373 (VDE 0115-0106):2011-04 |
| Spectrum/Mounting location | Service life test, Category 1, Class A/B |
| Functional test with noise-like oscillations | Test passed according to Section 8 of the standard |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| Acceleration | 0.101g (highest test level used for all axes) |
| Test duration per axis | 10 min. |
| Test directions | X, Y and Z axes |
| Monitoring of contact faults and interruptions | Passed |
| Voltage drop measurement before and after each axis | Passed |
| Simulated service life test through increased levels of noise-like oscillations | Test passed according to Section 9 of the standard |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| Acceleration | 0.572g (highest test level used for all axes) |
| Test duration per axis | 5 h |
| Test directions | X, Y and Z axes |
| Extended testing: Monitoring of contact faults and interruptions | Passed |
| Extended testing: Voltage drop measurement before and after each axis | Passed |
| Shock test | Test passed according to Section 10 of the standard |
| Shock pulse form | Half sine |
| Acceleration | 5g (highest test level used for all axes) |
| Shock duration | 30 ms |
| Number of shocks (per axis) | 3 pos. und 3 neg. |
| Test directions | X, Y and Z axes |
| Extended testing: Monitoring of contact faults and interruptions | Passed |
| Extended testing: Voltage drop measurement before and after each axis | Passed |
| Vibration and shock stress for rolling stock equipment | Passed |
Commercial data
| Product Group | 1 (Rail Mounted Terminal Blocks) |
| PU (SPU) | 5 pcs |
| Packaging type | box |
| Country of origin | PL |
| GTIN | 4045454507428 |
| Customs tariff number | 85369010000 |
Product Classification
| UNSPSC | 39121410 |
| eCl@ss 10.0 | 27-14-11-20 |
| eCl@ss 9.0 | 27-14-11-20 |
| ETIM 9.0 | EC000897 |
| ETIM 10.0 | EC000897 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |