Sick UC40-11211B
Quick facts
| Availability | Confirmed on request |
| Category | UC40 |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can UC40-11211B be shipped?
UC40-11211B is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up UC40-11211B in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for UC40-11211B and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for UC40-11211B, subject to availability and destination.
Ultrasonic distance sensors | UC40 | UC40-11211B | Communication interface: IO-Link | Operating range, limiting range: 65 mm ... 350 mm, 600 mm | Connection type: Male connector, M12, 5-pin | Sending axis: Straight | Response time: 64 ms | Digital output: 1 x push-pull: PNP/NPN | Communication Interface detail: IO-Link V1.1
Specifications
Features
| Operating range, limiting range | 65 mm ... 350 mm, 600 mm |
| Target | Natural objects |
| Resolution | ⥠0.1 mm |
| Repeatability | ± 0.15 % 1) |
| Measurement accuracy | ± 1 % 2) 3) |
| Temperature compensation | â |
| Response time | 64 ms 4) |
| Switching frequency | 10Â Hz |
| Output time | 16Â ms |
| Ultrasonic frequency (typical) | 400Â kHz |
| Detection area (typical) | See diagrams |
| Additional function | Adjustable operating modes: Switching point (DtO)Â /Â Switching window/Background (ObSB), teach-in of digital output, set levels of digital outputs, invertable digital output, set on delay digital output, synchronization of up to 50Â sensors, multiplexing: no cross talk of up to 50Â sensors, Adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam/False echo suppression, teach-in button(s) (can be deactivated), reset to factory default |
| MTTFD | 101Â years |
| DCavg | 0Â % |
Interfaces
| IO-Link | â , IO-Link V1.1 |
| Function | Process data, parameterization, diagnosis, data storage |
| Number | 1Â 1) |
| Type | Push-pull: PNP/NPN |
| Maximum output current IA | â¤Â 100 mA |
| Multifunctional input (MF) | 1 x MF |
| Hysteresis | 5Â mm |
Electronics
| Supply voltage UB | DC 9Â VÂ ... 30Â VÂ 1)Â 2) |
| Power consumption | â¤Â 1.5 W 3) |
| Initialization time | <Â 300Â ms |
| Indication | 4Â x LED |
| Enclosure rating | IP65IP67 |
| Protection class | III |
Mechanics
| Dimensions (W x H x D) | 40 mm x 40 mm x 66 mm |
| Design | Rectangular |
| Sending axis | Straight 1) |
| Housing material | Plastic (PA 66, ultrasonic transducer: polyurethane foam, glass epoxy resin) |
| Weight | 120Â g |
| Connection type | Male connector, M12, 5-pin |
Ambient data
| Ambient temperature, operation | â25 °C ... +70 °C |
| Ambient temperature, storage | â40 °C ... +85 °C |
Certificates
| EU declaration of conformity | â |
| UK declaration of conformity | â |
| ACMA declaration of conformity | â |
| Moroccan declaration of conformity | â |
| China RoHS | â |
| cULus certificate | â |
| Information according to Art. 3 of Data Act (Regulation EU 2023/2854) | â |
Classifications
| ECLASS 5.0 | 27270804 |
| ECLASS 5.1.4 | 27270804 |
| ECLASS 6.0 | 27270804 |
| ECLASS 6.2 | 27270804 |
| ECLASS 7.0 | 27270804 |
| ECLASS 8.0 | 27270804 |
| ECLASS 8.1 | 27270804 |
| ECLASS 9.0 | 27270804 |
| ECLASS 10.0 | 27270804 |
| ECLASS 11.0 | 27270804 |
| ECLASS 12.0 | 27272806 |
| ETIM 5.0 | EC001846 |
| ETIM 6.0 | EC001846 |
| ETIM 7.0 | EC001846 |
| ETIM 8.0 | EC001846 |
| UNSPSC 16.0901 | 41111960 |