Safety module, Modicon TM3 Safety, 2 Function, Cat 3 PL d/SIL CL2 (spring) 24 VDC
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modicon TM3 |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.19 kg |
Shipping & availability
When can TM3SAFL5RG be shipped?
TM3SAFL5RG is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up TM3SAFL5RG in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for TM3SAFL5RG and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for TM3SAFL5RG, subject to availability and destination.
This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The safety module provides 3 normally opened contacts and unlimited synchronisation time between inputs. It is a safety module with a rated supply voltage of 24V DC, an external supply current consumption of 100mA at 24V DC on power supply and a power consumption 0.2W at 5V DC, 3.6W at 24V DC. The main functions of this module are emergency stop, movable guard, multiple emergency stop, proximity sensor and electro-sensitive protection equipment (ESPE) monitoring. It is furnished with spring terminal for electrical connection. It is an IP20 rated product. Its dimensions are 43.7mm (Width) x 73mm (Depth) x 94mm (Height). It weighs 0.19kg. It is suitable for emergency stop, switch and safety light curtain monitoring applications. This product is certified by RCM, CSA, UL, TÜV, ANSI Haz Loc Class 1 Division 2, EAC. It supports wall mount using attached fasteners. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.
Specifications
Specifications
| Range of product | Modicon TM3 Safety |
| Product or component type | Safety module |
| Device short name | TM3SAFL |
| Safety module application | For emergency stop, switch and safety light curtain monitoring |
| Function of module | Emergency stop monitoring 2-channel wiring, Monitoring of a movable guard with 2 switches and automatic start, Monitoring of a movable guard, Multiple emergency stop monitoring 2-channel wiring, Proximity sensor monitoring PNP/PNP, Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP |
| Safety level | Can reach PL d/category 3 conforming to ISO 13849-1: 2008, Can reach PL d/category 3 conforming to ISO 13849-2: 2012, Can reach SILCL 2 conforming to IEC 62061: 2005, Can reach SIL 2 conforming to IEC 61508: 2010 |
| Safety reliability data | DC = 95 % conforming to ISO 13849-1, PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A, PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A, MTTFd = 500 years conforming to ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A, MTTFd = 85 years conforming to ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A, SFF = 95 % conforming to IEC 61508-1, HFT = 1 conforming to IEC 61508-1, Type = A conforming to IEC 61508-1 |
| Synchronisation time between inputs | Unlimited |
| Connections - terminals | Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34, Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34, Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34, Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34, Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34, Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals, Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals, Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals, Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals |
| Output type | Relay instantaneous opening, 3 NO circuit(s), potential free |
| Number of safety circuits | 3 NO for relay instantaneous opening |
| Maximum switching voltage | 230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening), 24 V utilisation category DC-13 (relay instantaneous opening) |
| [Us] rated supply voltage | 24 V - 15...20 % DC |
| Power consumption in W | 0.2 W at 5 V DC, 3.6 W at 24 V DC |
| Input protection type | Internal, electronic |
| [Uc] control circuit voltage | 24 V DC |
| Maximum cable distance between devices | 30 m |
| Breaking capacity | 4 A 24 V 50 ms DC-13 relay output |
| Output thermal current | 6 A per relay for relay output |
| [Ith] conventional free air thermal current | 18 A |
| Associated fuse rating | 4 A gG or gL for relay output conforming to IEC 60947-5-1, 6 A fast blow for relay output conforming to IEC 60947-5-1 |
| Minimum output current | 10 mA for relay output |
| Output voltage | 10 V relay output |
| Maximum response time on input open | 40 ms |
| [Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to IEC 60647-5-1 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to IEC 60647-5-1 |
| Current consumption | 100 mA at 24 V DC external supply |
| Local signalling | 8 LEDs (green/red) for user |
| Electrical connection | Spring terminal |
| Product compatibility | Safety light curtains conforming to EN/IEC 61496-1 (type 4) |
| Standards | IEC 60204-1, EN 1088/ISO 14119, ISO 13850, IEC 60947-1, IEC 60947-5-1 |
| Product certifications | CSA 61010-2-201 (pending), RCM, UL 61010-2-201, EAC, ANSI Haz Loc Class 1 Division 2 (pending), CSA Haz Loc Class 1 Division 2 (pending), TÜV |
| Marking | RCM, UL, CSA, EAC, CE, TÜV, EFUP 10 |
| Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2, Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2, Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3, Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3, Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3, Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4, 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5, Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6, Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011, Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011 |
| Mounting support | Top hat type TH35-7.5 rail conforming to IEC 60715, Top hat type TH35-15 rail conforming to IEC 60715, wall mount using attached fasteners |
| Height | 94 mm |
| Depth | 73 mm |
| Width | 43.7 mm |
| Net weight | 0.19 kg |
| Resistance to electrostatic discharge | 8 kV in air conforming to IEC 61000-4-2, 6 kV on contact conforming to IEC 61000-4-2 |
| Resistance to electromagnetic fields | 10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3, 1 V/m 2 GHz...3 GHz conforming to IEC 61000-4-3 |
| Resistance to magnetic fields | 30 A/m 50/60 Hz conforming to IEC 61000-4-8 |
| Resistance to fast transients | 3 kV for power lines (DC) (DC) conforming to IEC 61000-4-4, 2 kV for I/O lines conforming to IEC 61000-4-4 |
| Surge withstand | 1 kV power lines (DC) differential mode conforming to IEC 61000-4-5 DC, 1 kV power lines (DC) common mode conforming to IEC 61000-4-5 DC |
| Resistance to conducted disturbances | 10 V 0.15...80 MHz conforming to IEC 61000-4-6 |
| Electromagnetic emission | Radiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30…230 Hz conforming to IEC 61131-3, Radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230…1000 Hz conforming to IEC 61131-3 |
| Ambient air temperature for operation | -10…55 °C horizontal installation |
| Ambient air temperature for storage | -25…70 °C |
| Relative humidity | 10…95 %, without condensation (in operation), 10…95 %, without condensation (in storage) |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 |
| Pollution degree | 2 |
| Operating altitude | 0...2000 m |
| Storage altitude | 0…3000 m |
| Vibration resistance | +/- 3.5 mm (f= 5…150 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Mechanical robustness | Bumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27 |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.5 cm |
| Package 1 Width | 10.6 cm |
| Package 1 Length | 12.5 cm |
| Package 1 Weight | 262.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 18 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 5.272 kg |
| Warranty (in months) | 18 |
More Schneider Electric parts