Schneider Electric TM3SAC5R

Safety module, Modicon TM3, 1 function, Cat 3 PL d, SIL CL2, screw, 24V DC

MPN
TM3SAC5R
EAN
3606485392974
Category
Modicon TM3
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the Schneider Electric TM3SAC5R?

This TM3 safety expansion module monitors emergency shutdown pushbuttons and limit switches to conform to PLd / Category 3. It meets the requirements of PL d/Category 3 conforming to EN/ISO 13849-1 and SILCL 2 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.

Specifications

Specifications

Range of productModicon TM3 Safety
Product or component typeSafety module
Device short nameTM3SAC
Safety module applicationFor emergency stop and switch monitoring
Function of moduleEmergency stop monitoring 1-channel wiring, Emergency stop monitoring 2-channel wiring, Monitoring of a movable guard with 2 switches and automatic start
Safety levelCan reach PL d/category 3 conforming to ISO 13849-1: 2008, Can reach PL d/category 3 conforming to ISO 13849-2: 2012, Can reach SILCL 2 conforming to IEC 62061: 2005, Can reach SIL 2 conforming to IEC 61508: 2010
Safety reliability dataDC = 95 % conforming to ISO 13849-1, PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A, PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A, MTTFd = 500 years conforming to ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A, MTTFd = 85 years conforming to ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A, SFF = 95 % conforming to IEC 61508-1, HFT = 1 conforming to IEC 61508-1, Type = A conforming to IEC 61508-1
Synchronisation time between inputsUnlimited
Connections - terminalsCaptive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34, Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34, Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34, Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34, Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34, Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34, Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34, Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34, Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals, Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals, Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals, Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals, Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals, Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals, Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals, Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals
Output typeRelay instantaneous opening, 3 NO circuit(s), potential free
Number of safety circuits3 NO for relay instantaneous opening
Maximum switching voltage230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening), 24 V utilisation category DC-13 (relay instantaneous opening)
[Us] rated supply voltage24 V - 15...20 % DC
Power consumption in W0.2 W at 5 V DC, 3.6 W at 24 V DC
Input protection typeInternal, electronic
[Uc] control circuit voltage24 V DC
Maximum cable distance between devices30 m
Breaking capacity4 A 24 V 50 ms DC-13 relay output
Output thermal current6 A per relay for relay output
[Ith] conventional free air thermal current18 A
Associated fuse rating4 A gG or gL for relay output conforming to IEC 60947-5-1, 6 A fast blow for relay output conforming to IEC 60947-5-1
Minimum output current10 mA for relay output
Output voltage10 V relay output
Maximum response time on input open40 ms
[Ui] rated insulation voltage300 V (pollution degree 2) conforming to IEC 60647-5-1
[Uimp] rated impulse withstand voltage4 kV overvoltage category III conforming to IEC 60647-5-1
Current consumption100 mA at 24 V DC external supply (at state on)
Local signalling6 LEDs (green/red) for user
Electrical connectionScrew terminal
StandardsEN 1088/ISO 14119, ISO 13850, IEC 60947-1, IEC 60204-1, IEC 60947-5-1
Product certificationsTÜV, CSA 61010-2-201 (pending), CSA Haz Loc Class 1 Division 2 (pending), RCM, ANSI Haz Loc Class 1 Division 2 (pending), EAC, UL 61010-2-201
MarkingEFUP 10, RCM, CSA, UL, TÜV, CE, EAC
Electromagnetic compatibilityElectrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2, Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2, Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3, Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3, Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3, Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8, Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4, 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5, Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6, Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011, Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011
Mounting supportTop hat type TH35-7.5 rail conforming to IEC 60715, Top hat type TH35-15 rail conforming to IEC 60715, wall mount using attached fasteners
Height94 mm
Depth73 mm
Width43.7 mm
Net weight0.19 kg
Resistance to electrostatic discharge8 kV in air conforming to IEC 61000-4-2, 6 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3, 1 V/m 2 GHz...3 GHz conforming to IEC 61000-4-3
Resistance to magnetic fields30 A/m 50/60 Hz conforming to IEC 61000-4-8
Resistance to fast transients3 kV for power lines (DC) (DC) conforming to IEC 61000-4-4, 2 kV for I/O lines conforming to IEC 61000-4-4
Surge withstand1 kV power lines (DC) differential mode conforming to IEC 61000-4-5 DC, 1 kV power lines (DC) common mode conforming to IEC 61000-4-5 DC
Resistance to conducted disturbances10 V 0.15...80 MHz conforming to IEC 61000-4-6
Electromagnetic emissionRadiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30…230 Hz conforming to IEC 61131-3, Radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230…1000 Hz conforming to IEC 61131-3
Ambient air temperature for operation-10…55 °C horizontal installation
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 %, without condensation (in operation), 10…95 %, without condensation (in storage)
IP degree of protectionIP20 (terminals) conforming to IEC 60529
Pollution degree2
Operating altitude0...2000 m
Storage altitude0…3000 m
Vibration resistance+/- 3.5 mm (f= 5…150 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Mechanical robustnessBumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27

Packaging

Package 11 PCE, 12.500 cm × 10.600 cm × 7.500 cm (L × W × H), 283.000 g
Package 218 S03, 40.000 cm × 30.000 cm × 30.000 cm (L × W × H), 5.522 kg

Downloads & documentation

Official documents from Schneider Electric, downloaded directly from the manufacturer.

Data sheets & manuals

TM3SAC5R: frequently asked questions

When can TM3SAC5R be shipped?

TM3SAC5R is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up TM3SAC5R in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for TM3SAC5R and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for TM3SAC5R, subject to availability and destination.

More Schneider Electric parts

Schneider Electric TM3DQ8U – Discrete output module, Modicon TM3, 8 outputs transistor NPN, screw
Schneider Electric
TM3DQ8U

Discrete output module, Modicon TM3, 8 outputs transistor NPN, screw

Schneider Electric TM3DQ8UG – Discrete output module, Modicon TM3, 8 outputs transistor NPN (spring)
Schneider Electric
TM3DQ8UG

Discrete output module, Modicon TM3, 8 outputs transistor NPN (spring)

Schneider Electric TM3RDM16R – Discrete I/O module, Modicon TM3, 16 IO (8 digital inputs, 8 digital outputs, screw)
Schneider Electric
TM3RDM16R

Discrete I/O module, Modicon TM3, 16 IO (8 digital inputs, 8 digital outputs, screw)

Schneider Electric TM3RDM32R – Discrete I/O module, Modicon TM3, 32 IO (16 digital inputs, 16 digital outputs, screw)
Schneider Electric
TM3RDM32R

Discrete I/O module, Modicon TM3, 32 IO (16 digital inputs, 16 digital outputs, screw)

Schneider Electric TM3SAC5RG – Safety module, Modicon TM3, 1 function, Cat 3 PL d, SIL CL2, spring, 24V DC
Schneider Electric
TM3SAC5RG

Safety module, Modicon TM3, 1 function, Cat 3 PL d, SIL CL2, spring, 24V DC

Schneider Electric TM3SAF5R – Safety module, Modicon TM3, 1 function, Cat 4 PL e, SIL CL3, screw, 24V DC
Schneider Electric
TM3SAF5R

Safety module, Modicon TM3, 1 function, Cat 4 PL e, SIL CL3, screw, 24V DC

Schneider Electric TM3SAF5RG – Safety module, Modicon TM3, 1 function, Cat 4 PL e, SIL CL3, spring, 24V DC
Schneider Electric
TM3SAF5RG

Safety module, Modicon TM3, 1 function, Cat 4 PL e, SIL CL3, spring, 24V DC

Schneider Electric TM3SAFL5R – Safety module, Modicon TM3, 2 function, Cat 3 PL d, SIL CL2, screw, 24V DC
Schneider Electric
TM3SAFL5R

Safety module, Modicon TM3, 2 function, Cat 3 PL d, SIL CL2, screw, 24V DC

Schneider Electric TM3SAC5RPrice and lead time confirmed within 1 business day
Request a Quote