Pepperl Fuchs VBA-4E-G2-ZA
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VBA-4E-G2-ZA be shipped?
VBA-4E-G2-ZA is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBA-4E-G2-ZA in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBA-4E-G2-ZA and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E-G2-ZA, subject to availability and destination.
AS-Interface sensor module. G2 flat module, 4 inputs (PNP). Node type: A/B node. AS-Interface specification: V2.1. Required gateway specification: ≥ V2.0. UL File Number: E223772. LED FAULT: error display; LED redred: communication error or address is 0red flashing: overload of sensor supply. LED PWR: AS-Interface voltage; LED green. LED IN: switching state (input); 4 LED yellow. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 40 mA (without sensors) / max. 240 mA. Protection class: III. Surge protection: Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC. Supply: from AS-Interface. Voltage: 21 ... 31 V. Current loading capacity: ≤ 200 mA (TB ≤ 40 °C),≤ 150 mA (TB ≤ 60 °C), overload-proof and short-circuit protected. Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013: . Directive 2014/30/EU: EN 62026-2:2013. Degree of protection: EN 60529:2000. Input: EN 61131-2:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013. Profile: S-0.A.2. IO code: 0. ID code: A. ID1 code: 7. ID2 code: 2. Data bits (function via AS-Interface): InputOutput. D0 IN1 -D1 IN2 -D2 IN3 -D3 IN4 -: . D0: IN1 -. D1: IN2 -. D2: IN3 -. D3: IN4 -. Parameter bits (programmable via AS-i): function. P0not usedP1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings)P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings)P3not used: . P0: not used. P1: Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings). P2: Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings). P3: not used. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 3. Degree of protection: IP67. Connection: cable piercing methodflat cable yellowinputs: M12 round connector. Material: . HousingPBT: . Housing: PBT. Mass: 100 g. Tightening torque, cable gland: 0.4 Nm. Mounting: Mounting plate
Specifications
General specifications
| Node type | A/B node |
| AS-Interface specification | V2.1 |
| Required gateway specification | ≥ V2.0 |
| UL File Number | E223772 |
Indicators/operating means
| LED FAULT | error display; LED redred: communication error or address is 0red flashing: overload of sensor supply |
| LED PWR | AS-Interface voltage; LED green |
| LED IN | switching state (input); 4 LED yellow |
Electrical specifications
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 40 mA (without sensors) / max. 240 mA Ie |
| Protection class | III |
| Surge protection | Ue: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC |
| Supply | from AS-Interface |
| Voltage | 21 ... 31 V |
| Current loading capacity | ≤ 200 mA (TB ≤ 40 °C),≤ 150 mA (TB ≤ 60 °C), overload-proof and short-circuit protected |
| Input current | ≤ 8 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA | 0 (unattenuated) |
| 0 (unattenuated) | ≤ 2 mA |
| 1 (attenuated) | ≥ 4 mA |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Input | EN 61131-2:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Programming instructions
| Profile | S-0.A.2 |
| IO code | 0 |
| ID code | A |
| ID1 code | 7 |
| ID2 code | 2 |
| Data bits (function via AS-Interface) | InputOutput |
| D0 IN1 -D1 IN2 -D2 IN3 -D3 IN4 - | D0 |
| D0 | IN1 - |
| D1 | IN2 - |
| D2 | IN3 - |
| D3 | IN4 - |
| Parameter bits (programmable via AS-i) | function |
| P0not usedP1Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings)P2Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings)P3not used | P0 |
| P0 | not used |
| P1 | Input filterP1 = 0 input filter on, pulse suppression ≤ 2 msP1 = 1 input filter off (default settings) |
| P2 | Synchronous modeP2 = 0 synchronous mode onP2 = 1 synchronous mode off (default settings) |
| P3 | not used |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 3 |
Mechanical specifications
| Degree of protection | IP67 |
| Connection | cable piercing methodflat cable yellowinputs: M12 round connector |
| Material | |
| HousingPBT | Housing |
| Housing | PBT |
| Mass | 100 g |
| Tightening torque, cable gland | 0.4 Nm |
| Mounting | Mounting plate |
More Pepperl Fuchs parts