Pepperl Fuchs VBA-4E-G11-I-F
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VBA-4E-G11-I-F be shipped?
VBA-4E-G11-I-F is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBA-4E-G11-I-F in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBA-4E-G11-I-F and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E-G11-I-F, subject to availability and destination.
AS-Interface analog module. G11 analog module, 4 analog current inputs. Node type: Standard node. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.1. Profile: S-7.3.E. IO code7ID code3ID1 codeFID2 codeE: . IO code: 7. ID code: 3. ID1 code: F. ID2 code: E. UL File Number: E223772. LED AS-i/FAULT: Status display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault. LED ANALOG: status of input signal; LED yellowoff: not activeon: signal within measuring rangeflashing: signal outside of measuring range. LED AUX: ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage. LED INT/EXT: status display input supply; LED greengreen: input supply from AS-Interfaceoff: input supply from auxiliary voltage. Auxiliary voltage (output): 20 ... 30 V DC PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 60 mA (without sensors) / max. 200 mA. Protection class: III. Surge protection: UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 Inputs 0/4 ... 20 mA. Supply: from AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT). Current loading capacity: ≤ 140 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA from external auxiliary voltage UAUX , overload and short-circuit protected. Input resistance: max. 70 Ω. Accuracy: 0.1 % of full-scale value. Resolution: 16 Bit. Temperature influence: 0.0025 %/K of input signal range. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013: . Directive 2014/30/EU: EN 62026-2:2013. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2:2007. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 3. Degree of protection: IP68 / IP69K. Connection: AS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Inputs: M12 round connector. Material: . HousingPBT PCMounting screwStainless steel 1.4305 / AISI 303: . Housing: PBT PC. Mounting screw: Stainless steel 1.4305 / AISI 303. Mass: 200 g. Tightening torque, housing screws: 1.8 Nm. Tightening torque, cable gland: 0.4 Nm. Dimensions: . Height35 mmDiameter85 mm: . Height: 35 mm. Diameter: 85 mm. Mounting: Mounting plate
Specifications
General specifications
| Node type | Standard node |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V2.1 |
| Profile | S-7.3.E |
| IO code7ID code3ID1 codeFID2 codeE | IO code |
| IO code | 7 |
| ID code | 3 |
| ID1 code | F |
| ID2 code | E |
| UL File Number | E223772 |
Indicators/operating means
| LED AS-i/FAULT | Status display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault |
| LED ANALOG | status of input signal; LED yellowoff: not activeon: signal within measuring rangeflashing: signal outside of measuring range |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage |
| LED INT/EXT | status display input supply; LED greengreen: input supply from AS-Interfaceoff: input supply from auxiliary voltage |
Electrical specifications
| Auxiliary voltage (output) | 20 ... 30 V DC PELV UAUX |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 60 mA (without sensors) / max. 200 mA Ie |
| Protection class | III |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 Inputs 0/4 ... 20 mA |
| Supply | from AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) |
| Current loading capacity | ≤ 140 mA from AS-Interface; overload and short-circuit resistant ≤ 600 mA from external auxiliary voltage UAUX , overload and short-circuit protected |
| Input resistance | max. 70 Ω |
| Accuracy | 0.1 % of full-scale value |
| Resolution | 16 Bit |
| Temperature influence | 0.0025 %/K of input signal range |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2:2007 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 3 |
Mechanical specifications
| Degree of protection | IP68 / IP69K |
| Connection | AS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Inputs: M12 round connector |
| Material | |
| HousingPBT PCMounting screwStainless steel 1.4305 / AISI 303 | Housing |
| Housing | PBT PC |
| Mounting screw | Stainless steel 1.4305 / AISI 303 |
| Mass | 200 g |
| Tightening torque, housing screws | 1.8 Nm |
| Tightening torque, cable gland | 0.4 Nm |
| Dimensions | |
| Height35 mmDiameter85 mm | Height |
| Height | 35 mm |
| Diameter | 85 mm |
| Mounting | Mounting plate |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G