Pepperl Fuchs VBA-2A-G11-I-V1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VBA-2A-G11-I-V1 be shipped?
VBA-2A-G11-I-V1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBA-2A-G11-I-V1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBA-2A-G11-I-V1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-2A-G11-I-V1, subject to availability and destination.
AS-Interface analog module. G11 analog module, 2 analog outputs. Node type: Standard node. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.1. Profile: S-7.3.5. IO code7ID code3ID1 codeFID2 code5: . IO code: 7. ID code: 3. ID1 code: F. ID2 code: 5. UL File Number: E223772. LED AS-i/FAULT: Status display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault. LED ANALOG: Status of output signal; yellow LEDYellow: 0 mA ≤ I ≤ 23 mAYellow flashing: lead breakage or I > 23 mA. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 100 mA. Protection class: III. Surge protection: Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 2 analog outputs (current), 0 ... 20 mA. Supply: from AS-Interface. Load: max. 600 Ω. Resolution: 6 µA. Accuracy: 0.15 % of full-scale value. Temperature influence: 1 µA/K. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013: . Directive 2014/30/EU: EN 62026-2:2013. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005, EN 61326-1:2006, IEC 62026-2:2008. Ambient temperature: -25 ... 70 °C (-13 ... 158 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 3. Degree of protection: IP68 / IP69K. Connection: AS-Interface: M12 round connector Outputs: M12 round connector. Material: . HousingPBT PCMounting screwStainless steel 1.4305 / AISI 303: . Housing: PBT PC. Mounting screw: Stainless steel 1.4305 / AISI 303. Mass: 200 g. Tightening torque, housing screws: 1.8 Nm. Tightening torque, cable gland: 0.4 Nm. Dimensions: . Height35 mmDiameter85 mm: . Height: 35 mm. Diameter: 85 mm. Mounting: Mounting plate
Specifications
General specifications
| Node type | Standard node |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V2.1 |
| Profile | S-7.3.5 |
| IO code7ID code3ID1 codeFID2 code5 | IO code |
| IO code | 7 |
| ID code | 3 |
| ID1 code | F |
| ID2 code | 5 |
| UL File Number | E223772 |
Indicators/operating means
| LED AS-i/FAULT | Status display; multi-colour LEDGreen: normal operationRed: communication faultFlashing yellow/red: address 0Flashing green/red: peripheral fault |
| LED ANALOG | Status of output signal; yellow LEDYellow: 0 mA ≤ I ≤ 23 mAYellow flashing: lead breakage or I > 23 mA |
Electrical specifications
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 100 mA Ie |
| Protection class | III |
| Surge protection | Ue: Over voltage category III, safe isolated power supplies (PELV) |
Output
| Number/Type | 2 analog outputs (current), 0 ... 20 mA |
| Supply | from AS-Interface |
| Load | max. 600 Ω |
| Resolution | 6 µA |
| Accuracy | 0.15 % of full-scale value |
| Temperature influence | 1 µA/K |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 62026-2:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 62026-2:2013 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, IEC 62026-2:2008 |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 3 |
Mechanical specifications
| Degree of protection | IP68 / IP69K |
| Connection | AS-Interface: M12 round connector Outputs: M12 round connector |
| Material | |
| HousingPBT PCMounting screwStainless steel 1.4305 / AISI 303 | Housing |
| Housing | PBT PC |
| Mounting screw | Stainless steel 1.4305 / AISI 303 |
| Mass | 200 g |
| Tightening torque, housing screws | 1.8 Nm |
| Tightening torque, cable gland | 0.4 Nm |
| Dimensions | |
| Height35 mmDiameter85 mm | Height |
| Height | 35 mm |
| Diameter | 85 mm |
| Mounting | Mounting plate |