Pepperl Fuchs VAA-4E4A-CB-ZE/E2-Y129640
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VAA-4E4A-CB-ZE/E2-Y129640 be shipped?
VAA-4E4A-CB-ZE/E2-Y129640 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VAA-4E4A-CB-ZE/E2-Y129640 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VAA-4E4A-CB-ZE/E2-Y129640 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VAA-4E4A-CB-ZE/E2-Y129640, subject to availability and destination.
AS-Interface printed circuit board module. Circuit board module, 4 inputs/4 outputs. Node type: Standard node. AS-Interface specification: V2.1. LED FAULT: error display; LED redred: communication error or address is 0red flashing: overload of outputs. LED PWR: AS-Interface voltage; LED green. LED AUX: ext. auxiliary voltage UAUX ; LED green. LED IN: switching state (input); 4 LED yellow. LED OUT: Switching state (output); 4 LED yellow. Auxiliary voltage (input): 20 ... 30 V DC PELV. Auxiliary voltage (output): 20 ... 30 V DC PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 40 mA. Protection class: III. Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from external auxiliary voltage UEXT. Input current: ≤ 8 mA (limited internally). Switching point: according to EN 61131-2 Type 2. 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Number/Type: 4 electronic outputs, PNP. Supply: from external auxiliary voltage UAUX. Current: ≤ 700 mA per output. Degree of protection: EN 60529:2000. AS-Interface: EN 62026-2:2013. Profile: S-7.0. IO code: 7. ID code: 0. ID1 code: F. ID2 code: E. Data bits (function via AS-Interface): InputOutput. D0 IN1 OUT1D1 IN2 OUT2D2 IN3 OUT3D3 IN4 OUT4: . D0: IN1 OUT1. D1: IN2 OUT2. D2: IN3 OUT3. D3: IN4 OUT4. Parameter bits (programmable via AS-i): function. P0not usedP1not usedP2not usedP3not used: . P0: not used. P1: not used. P2: not used. P3: not used. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Connection: Card edge connector, type AMP 145432-2. Mass: approx. 13 g. Dimensions: 65.7 mm x 40 mm x 8 mm. Width40 mmLength65.7 mm: . Width: 40 mm. Length: 65.7 mm
Specifications
General specifications
| Node type | Standard node |
| AS-Interface specification | V2.1 |
Indicators/operating means
| LED FAULT | error display; LED redred: communication error or address is 0red flashing: overload of outputs |
| LED PWR | AS-Interface voltage; LED green |
| LED AUX | ext. auxiliary voltage UAUX ; LED green |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | Switching state (output); 4 LED yellow |
Electrical specifications
| Auxiliary voltage (input) | 20 ... 30 V DC PELV UEXT |
| Auxiliary voltage (output) | 20 ... 30 V DC PELV UAUX |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 40 mA Ie |
| Protection class | III |
Input
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
| Supply | from external auxiliary voltage UEXT |
| Input current | ≤ 8 mA (limited internally) |
| Switching point | according to EN 61131-2 Type 2 |
| 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA | 0 (unattenuated) |
| 0 (unattenuated) | ≤ 2 mA |
| 1 (attenuated) | ≥ 4 mA |
Output
| Number/Type | 4 electronic outputs, PNP |
| Supply | from external auxiliary voltage UAUX |
| Current | ≤ 700 mA per output |
Standard conformity
| Degree of protection | EN 60529:2000 |
| AS-Interface | EN 62026-2:2013 |
Programming instructions
| Profile | S-7.0 |
| IO code | 7 |
| ID code | 0 |
| ID1 code | F |
| ID2 code | E |
| Data bits (function via AS-Interface) | InputOutput |
| D0 IN1 OUT1D1 IN2 OUT2D2 IN3 OUT3D3 IN4 OUT4 | D0 |
| D0 | IN1 OUT1 |
| D1 | IN2 OUT2 |
| D2 | IN3 OUT3 |
| D3 | IN4 OUT4 |
| Parameter bits (programmable via AS-i) | function |
| P0not usedP1not usedP2not usedP3not used | P0 |
| P0 | not used |
| P1 | not used |
| P2 | not used |
| P3 | not used |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Mechanical specifications
| Connection | Card edge connector, type AMP 145432-2 |
| Mass | approx. 13 g |
| Dimensions | 65.7 mm x 40 mm x 8 mm |
| Width40 mmLength65.7 mm | Width |
| Width | 40 mm |
| Length | 65.7 mm |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G


