Pepperl Fuchs SK-PC-D2-UU1-10-HS (2024 Generation)
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Peripherals |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SK-PC-D2-UU1-10-HS (2024 Generation) be shipped?
SK-PC-D2-UU1-10-HS (2024 Generation) is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SK-PC-D2-UU1-10-HS (2024 Generation) in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SK-PC-D2-UU1-10-HS (2024 Generation) and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SK-PC-D2-UU1-10-HS (2024 Generation), subject to availability and destination.
Div. 2 / Zone 2 Ex-rated barrier. Div. 2 / Zone 2 Ex-rated barrier, 1- or 2-channel Division 2 non-incendive barrier, Div 2/Zone 2 mountable, USB interface for Ex-rated keyboard or mouse. Rated voltage: 9 ... 30 VDC (Um = 30 V SELV). Input current: 120 mA nominal500 mA max. LED ON: power - Channel 1power - Channel 2. Interface type: USB 1.1. Output current: 89 mA. Output voltage: 4.8 VDC. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations) #224258: . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations) #224258. RoHS: . Directive 2011/65/EU (RoHS)EN IEC 63000:2018: . Directive 2011/65/EU (RoHS): EN IEC 63000:2018. Degree of protection: IEC 60529. Protection against electrical shock: IEC 61140. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F). Relative humidity: 0 ... 95% (noncondensing). Vibration resistance: 5 G, 58 ... 150 Hz. Impact resistance: 15 g, 11 ms. Connection type: Terminal Block. Degree of protection: IP20. Connection: Supply: terminals 13+, 14-Input: terminals 9+, 10-; 11+, 12-Output: terminals 1+, 2+, 3-, 4-; 5+, 6+, 7-, 8- (field terminal) Ground: terminals 15, 16. Mass: 120 g. Dimensions: 99 mm x 85 mm x 22.5 mm. Cable length: Max. 5 m (15'): barrier to keyboard/mouseMax. 5 m (15'): host pc to keyboard/mouse. EU-type examination certificate: DEMKO 14ATEX1269806X. Marking II 3G Ex ec [ic Gc] IIC T6 Gc [exsign] II (3)D [Ex ic Dc] IIIB: . Marking: II 3G Ex ec [ic Gc] IIC T6 Gc [exsign] II (3)D [Ex ic Dc] IIIB. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018/A11:2024 EN IEC 60079-7:2015/A1:2018 EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018/A11:2024 EN IEC 60079-7:2015/A1:2018 EN 60079-11:2012. UL approval: cULus (E106378). Control drawing116-0337CApproved forMountable inClass I, Division 2, Groups A, B, C, DProviding non-incendive field wiring at field terminals toClass I, Division 2, Groups A, B, C, DClass II, Division 2, Groups F, GClass IIITemperature Class T6 Mountable inClass I, Zone 2Providing intrinsic safety wiring at field terminals for hazardous locations US:Class I Zone 2, AEx ec [ic Gc] IIC T6 GcClass I Zone 2, [AEx ic Dc] IIIBCAN:Ex ec [ic Gc] IIC T6 Gc X[Ex ic Dc] IIIB X: . Control drawing: 116-0337C. Approved for: Mountable inClass I, Division 2, Groups A, B, C, DProviding non-incendive field wiring at field terminals toClass I, Division 2, Groups A, B, C, DClass II, Division 2, Groups F, GClass IIITemperature Class T6 Mountable inClass I, Zone 2Providing intrinsic safety wiring at field terminals for hazardous locations US:Class I Zone 2, AEx ec [ic Gc] IIC T6 GcClass I Zone 2, [AEx ic Dc] IIIBCAN:Ex ec [ic Gc] IIC T6 Gc X[Ex ic Dc] IIIB X. IECEx approval: IECEx UL 14.0017X. Approved forEx ec [ic Gc] IIC T6 Gc [Ex ic Dc] IIIBStandardsIEC 60079-0:2017 Ed 7.0 IEC 60079-7:2015 Ed 5.1 IEC 60079-11:2011 Ed 6.0: . Approved for: Ex ec [ic Gc] IIC T6 Gc [Ex ic Dc] IIIB. Standards: IEC 60079-0:2017 Ed 7.0 IEC 60079-7:2015 Ed 5.1 IEC 60079-11:2011 Ed 6.0
Specifications
Supply
| Rated voltage | 9 ... 30 VDC (Um = 30 V SELV) Ur |
| Input current | 120 mA nominal500 mA max |
Indicators/operating means
| LED ON | power - Channel 1power - Channel 2 |
Interface
| Interface type | USB 1.1 |
Output
| Output current | 89 mA |
| Output voltage | 4.8 VDC |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) #224258 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) #224258 |
| RoHS | |
| Directive 2011/65/EU (RoHS)EN IEC 63000:2018 | Directive 2011/65/EU (RoHS) |
| Directive 2011/65/EU (RoHS) | EN IEC 63000:2018 |
Conformity
| Degree of protection | IEC 60529 |
| Protection against electrical shock | IEC 61140 |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Relative humidity | 0 ... 95% (noncondensing) |
| Vibration resistance | 5 G, 58 ... 150 Hz |
| Impact resistance | 15 g, 11 ms |
Mechanical specifications
| Connection type | Terminal Block |
| Degree of protection | IP20 |
| Connection | Supply: terminals 13+, 14-Input: terminals 9+, 10-; 11+, 12-Output: terminals 1+, 2+, 3-, 4-; 5+, 6+, 7-, 8- (field terminal) Ground: terminals 15, 16 |
| Mass | 120 g |
| Dimensions | 99 mm x 85 mm x 22.5 mm |
| Cable length | Max. 5 m (15'): barrier to keyboard/mouseMax. 5 m (15'): host pc to keyboard/mouse |
Data for application in connection with hazardous areas
| EU-type examination certificate | DEMKO 14ATEX1269806X |
| Marking II 3G Ex ec [ic Gc] IIC T6 Gc [exsign] II (3)D [Ex ic Dc] IIIB | Marking |
| Marking | II 3G Ex ec [ic Gc] IIC T6 Gc [exsign] II (3)D [Ex ic Dc] IIIB |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018/A11:2024 EN IEC 60079-7:2015/A1:2018 EN 60079-11:2012 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018/A11:2024 EN IEC 60079-7:2015/A1:2018 EN 60079-11:2012 |
International approvals
| UL approval | cULus (E106378) |
| Control drawing116-0337CApproved forMountable inClass I, Division 2, Groups A, B, C, DProviding non-incendive field wiring at field terminals toClass I, Division 2, Groups A, B, C, DClass II, Division 2, Groups F, GClass IIITemperature Class T6 Mountable inClass I, Zone 2Providing intrinsic safety wiring at field terminals for hazardous locations US:Class I Zone 2, AEx ec [ic Gc] IIC T6 GcClass I Zone 2, [AEx ic Dc] IIIBCAN:Ex ec [ic Gc] IIC T6 Gc X[Ex ic Dc] IIIB X | Control drawing |
| Control drawing | 116-0337C |
| Approved for | Mountable inClass I, Division 2, Groups A, B, C, DProviding non-incendive field wiring at field terminals toClass I, Division 2, Groups A, B, C, DClass II, Division 2, Groups F, GClass IIITemperature Class T6 Mountable inClass I, Zone 2Providing intrinsic safety wiring at field terminals for hazardous locations US:Class I Zone 2, AEx ec [ic Gc] IIC T6 GcClass I Zone 2, [AEx ic Dc] IIIBCAN:Ex ec [ic Gc] IIC T6 Gc X[Ex ic Dc] IIIB X |
| IECEx approval | IECEx UL 14.0017X |
| Approved forEx ec [ic Gc] IIC T6 Gc [Ex ic Dc] IIIBStandardsIEC 60079-0:2017 Ed 7.0 IEC 60079-7:2015 Ed 5.1 IEC 60079-11:2011 Ed 6.0 | Approved for |
| Approved for | Ex ec [ic Gc] IIC T6 Gc [Ex ic Dc] IIIB |
| Standards | IEC 60079-0:2017 Ed 7.0 IEC 60079-7:2015 Ed 5.1 IEC 60079-11:2011 Ed 6.0 |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs SK-IDM-Z2-J2-5M-S-N
Available on requestPepperl Fuchs SK-KVM-xxx-CW-20-CR-N Series
Available on requestPepperl Fuchs SK-KVM-xxx-FW-20-CR-N Series
Available on requestPepperl Fuchs SK-KVM-xxx-NR-20-CR-N Series
Available on requestPepperl Fuchs SK-PC-Z1D1-UU1-10-HS
Available on requestPepperl Fuchs SL-2ES-2SC
Available on requestPepperl Fuchs SL-RP/GS130/GS190
Available on requestPepperl Fuchs SL-RP/GS80