Pepperl Fuchs NDP-KE2-8E2
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Wireless Inductive System (WIS) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can NDP-KE2-8E2 be shipped?
NDP-KE2-8E2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up NDP-KE2-8E2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for NDP-KE2-8E2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NDP-KE2-8E2, subject to availability and destination.
WIS module primary. Operating voltage: 24 V DC ± 10 %. Number of signal channels: 8. Signal transfer direction: from secondary side to primary side. Reverse polarity protection: reverse polarity protected. Current consumption: max. 1000 mA. MTTFd: 245 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Switching state: 8 x LED, yellow. Transfer indicator: LED, green. Number: 1. Input type: Activation inputsignal level: ≥ 15 V = active, ≤ 3 V inactive. Input current: ≤ 1 mA. Internal resistor: ≥ 15 kΩ. Output type: 1 Status output (high with proper transfer) and 8 Switch outputs PNP, NO. (switched high) , overload and short-circuit resistant. Voltage drop: ≤ 2.5 V. Load current: max. 50 mA. Response time: ≤ 200 ms ( static operation , the transmission heads stand opposite to each other ). Directive conformity: . EMC Directive 89/336/EECEN 61000-6-2:2001, EN 61000-6-4:2001, EN 50295:1999: . EMC Directive 89/336/EEC: EN 61000-6-2:2001, EN 61000-6-4:2001, EN 50295:1999. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: 0 ... 50 °C (32 ... 122 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Degree of protection: IP20. Material: . HousingPA 66-FR: . Housing: PA 66-FR. Installation: DIN rail mounting. Mass: 106 g. Note: Maximum cable length between WIS module and WIS transmitter must not exceed 5 m.
Specifications
Nominal ratings
| Operating voltage | 24 V DC ± 10 % UB |
| Number of signal channels | 8 |
| Signal transfer direction | from secondary side to primary side |
| Reverse polarity protection | reverse polarity protected |
| Current consumption | max. 1000 mA |
Functional safety related parameters
| MTTFd | 245 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means
| Switching state | 8 x LED, yellow |
| Transfer indicator | LED, green Tx |
Input
| Number | 1 |
| Input type | Activation inputsignal level: ≥ 15 V = active, ≤ 3 V inactive |
| Input current | ≤ 1 mA |
| Internal resistor | ≥ 15 kΩ |
Output
| Output type | 1 Status output (high with proper transfer) and 8 Switch outputs PNP, NO. (switched high) , overload and short-circuit resistant |
| Voltage drop | ≤ 2.5 V Ud |
| Load current | max. 50 mA |
| Response time | ≤ 200 ms ( static operation , the transmission heads stand opposite to each other ) |
Compliance with standards and directives
| Directive conformity | |
| EMC Directive 89/336/EECEN 61000-6-2:2001, EN 61000-6-4:2001, EN 50295:1999 | EMC Directive 89/336/EEC |
| EMC Directive 89/336/EEC | EN 61000-6-2:2001, EN 61000-6-4:2001, EN 50295:1999 |
Approvals and certificates
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | 0 ... 50 °C (32 ... 122 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Material | |
| HousingPA 66-FR | Housing |
| Housing | PA 66-FR |
| Installation | DIN rail mounting |
| Mass | 106 g |
General information
| Note | Maximum cable length between WIS module and WIS transmitter must not exceed 5 m. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G