What is the Pepperl Fuchs LB4002A2?

1-channel

Analog output module for 0/4 mA ... 20 mA

Installation in Zone 2 or safe area

HART communication via field bus or service bus

Simulation mode for service operations (forcing)

Line fault detection (LFD)

Permanently self-monitoring

1-channel, Analog output module for 0/4 mA ... 20 mA, Installation in Zone 2 or safe area, HART communication via field bus or service bus, Explosion protection: Ex ic, Field device: Proportional Valve, Field device [2]: I/P converters, Field device [3]: on-site display

Specifications

Slots

Order code (Pepperl+Fuchs part number)254718
Occupied slots1
LifecycleActive (current Pepperl+Fuchs product)

Supply

Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies LB9*** Ur
Power dissipation0.8 W
Power consumption0.95 W

Internal bus

Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit

Analog output

Number of channels1
Suitable field devices: Field deviceProportional Valve
Suitable field devices: Field device [2]I/P converters
Suitable field devices: Field device [3]on-site display
Connectionchannel I: 2/3+, 4/5-
Current0 ... 25 mA short-circuit protected
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
Short-circuitNo
Open-circuitdeviation of preset output value > 0.5 mA
Load750 Ω max.
HART communicationyes
HART secondary variableMODBUS: yes; all other bus systems: no
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication

Transfer characteristics

Deviation: After calibration0.1 % of the signal range at 20 °C (68 °F)
Deviation: Influence of ambient temperature0.1 %/10 K of the signal range
Refresh time100 ms

Indicators/settings

LED indicationPower LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1) red: line fault (lead breakage or short circuit)
Codingoptional mechanical coding via front socket

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013

Conformity

Electromagnetic compatibilityNE 21:2007
Degree of protectionIEC 60529:2000
Environmental testEN 60068-2-14:2009
Shock resistanceEN 60068-2-27:2009
Vibration resistanceEN 60068-2-6:2008
Damaging gasEN 60068-2-42:2003
Relative humidityEN 60068-2-78:2001

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F) , 70 °C (non-Ex)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Altitudemax. 2000 m
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protectionIP20 when mounted on backplane
Connectionremovable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Massapprox. 90 g
Dimensions: Height100 mm
Dimensions: Width16 mm
Dimensions: Depth102 mm

Data for application in connection with hazardous areas

CertificateBVS 12 ATEX E 115 X
MarkingII 3 G Ex nA [ic] IIC T4 Gc
Galvanic isolation: Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN IEC 60079-11:2024 EN 60079-15:2010

International approvals

ATEX approvalBVS 12 ATEX E 115 X
IECEx approval: IECEx certificateIECEx BVS 11.0068X
IECEx approval: IECEx markingEx nA [ic] IIC T4 Gc

General information

System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

LB4002A2: frequently asked questions

When can LB4002A2 be shipped?

LB4002A2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up LB4002A2 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for LB4002A2 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB4002A2, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs LB3006A – HART Transmitter Power Supply
Pepperl Fuchs
LB3006A

HART Transmitter Power Supply

Pepperl Fuchs LB3102A2 – HART Transmitter Power Supply, Input Isolator
Pepperl Fuchs
LB3102A2

HART Transmitter Power Supply, Input Isolator

Pepperl Fuchs LB3105A2 – HART Transmitter Power Supply, Input Isolator
Pepperl Fuchs
LB3105A2

HART Transmitter Power Supply, Input Isolator

Pepperl Fuchs LB3106A – HART Transmitter Power Supply
Pepperl Fuchs
LB3106A

HART Transmitter Power Supply

Pepperl Fuchs LB4005C2 – HART Output Isolator with Shutdown Input
Pepperl Fuchs
LB4005C2

HART Output Isolator with Shutdown Input

Pepperl Fuchs LB4102C2 – HART Output Isolator with Shutdown Input
Pepperl Fuchs
LB4102C2

HART Output Isolator with Shutdown Input

Pepperl Fuchs LB4105C2 – HART Output Isolator with Shutdown Input
Pepperl Fuchs
LB4105C2

HART Output Isolator with Shutdown Input

Pepperl Fuchs LB4106C – HART Output Isolator with Shutdown Input
Pepperl Fuchs
LB4106C

HART Output Isolator with Shutdown Input